Publications by authors named "Nimfa Stojek"

A total of 123 water samples were examined in parallel by culture and semi-nested PCR for the presence of Legionella. They comprised: 35 samples of hot water distributed by the urban municipal water supply system (MWSS) taken in institutions, 45 samples of hot water distributed by urban MWSS taken in dwellings, 27 samples of cold water distributed by rural MWSS taken in dwellings, and 16 samples of cold well water taken in rural areas. The greatest frequency of the isolation of Legionella by culture (88.

View Article and Find Full Text PDF

The aim of the present study was: - to compare methods for concentration and isolation of Legionella DNA from water; - to examine the efficacy of various modifications of PCR test (PCR, semi-nested PCR, and real-time PCR) for the detection of known numbers of Legionella pneumophila in water samples artificially contaminated with the strain of this bacterium and in randomly selected samples of environmental water, in parallel with examination by culture. It was found that filtration is much more effective than centrifugation for the concentration of DNA in water samples, and that the Qiamp DNA Mini-Kit is the most efficient for isolation of Legionella DNA from water. The semi-nested PCR and real-time PCR proved to be the most sensitive methods for detection of Legionella DNA in water samples.

View Article and Find Full Text PDF

A total of 320 potable water samples were collected from various rural and urban sources located in the Lublin region of eastern Poland. They comprised: 55 samples of treated (chlorinated) tap water from rural dwellings distributed by the municipal water supply system (MWSS), 111 samples of treated tap water from urban dwellings distributed by the MWSS, 45 samples of untreated well water from household wells and 109 samples from private water supply systems (PWSS) distributing untreated well water. Water samples were examined for the presence and species composition of Legionella, Yersinia, Gram-negative bacteria belonging to family Enterobacteriaceae (GNB-E) and Gram-negative bacteria not belonging to the family Enterobacteriaceae (GNB-NE), by filtering through cellulose filters and culture on respectively GVPC, CIN, EMB and tryptic soya agar media.

View Article and Find Full Text PDF

The aim of this work was to evaluate three currently available isolation methods for Legionella using water samples and swabs of a single pediatric hospital water system. Additionally, high risk patients were screened for the presence of Legionella pneumophila antigen in urine. Fifteen water samples and 11 swab samples were collected from distal sites at 18 sampling locations.

View Article and Find Full Text PDF

A total of 67 samples of tap water were collected from faucets and showerheads in 6 hospitals located in the Lublin province (eastern Poland). The samples were examined for the presence and species composition of Legionella, Gram-negative bacteria belonging to family Enterobacteriaceae (GNB-E) and Gram-negative bacteria not belonging to family Enterobacteriaceae (GNB-NE), by filtering through cellulose filters and culture on respectively GVPC, EMB and tryptic soya agar media. On average, Legionella was isolated from 65.

View Article and Find Full Text PDF

A total of 107 potable water samples were collected from various rural and urban sources located in the Lublin region (eastern Poland). 54 samples from rural sources comprised 32 samples of untreated well water and 22 samples of treated (chlorinated) tap water from rural dwellings distributed by the municipal water supply system (MWSS). 53 samples of treated water from urban sources were supplied by the city of Lublin MWSS.

View Article and Find Full Text PDF

The objective of the study was to determine the prevalence rate of 3 Borrelia burgdorferi genospecies in Ixodes ricinus ticks collected from wooded areas of the Lublin region (eastern Poland). A group of 1,813 I. ricinus ticks from 6 districts were examined for the presence of Borrelia burgdorferi sensu lato (B.

View Article and Find Full Text PDF

Microbial quality of water in a dental unit is of considerable importance since patients and dental staff are regularly exposed to water and aerosol generated by the unit. Water delivered to a dental unit by the so-called independent water system is the water coming from a reservoir which, at the same time, is an initial part of dental unit waterlines (DUWL). Thus, microbiological quality of this water is extremely important for the quality of water flowing from dental handpieces.

View Article and Find Full Text PDF

A total of 372 Ixodes ricinus ticks (101 females, 122 males, and 149 nymphs) collected by flagging in 6 mixed woodlands of eastern Poland were examined by culture for the presence of internal Gram-negative bacteria other than Borrelia burgdorferi. Adult ticks were examined in pools of 2 specimens each and nymphs were examined in pools of 3-5 specimens each. Ticks were disinfected in 70 % ethanol and homogenized in 0.

View Article and Find Full Text PDF

In the literature, there are case reports suggesting that Borrelia burgdorferi infection may induce autoimmune diseases dependent on antinuclear antibodies (ANA). The present study was undertaken in order to verify this possibility in a prospective manner. The study group comprised 78 consecutive patients (51 women and 27 men, median age 41.

View Article and Find Full Text PDF

Rural inhabitants are exposed to considerable amounts of pesticides from water, soil and air. There are indications that exposure to pesticides may trigger production of antinuclear antibodies (ANA). Therefore, the question arises about the prevalence of ANA in this group.

View Article and Find Full Text PDF

To study a possibility of infection with Legionella at gardening by inhaling of water aerosolized at sprinkling of plants, samples of tap water used for sprinkling of plants grown in outdoor gardens and in greenhouses in the Lublin province (eastern Poland) were examined for the presence of Legionella, along with the samples of soil, artificial medium and air collected in modern greenhouses. The strains of Legionella were isolated from 8 out of 36 samples of water (22.2%) collected from outdoor taps used for sprinkling plants cultivated in outdoor gardens, and from 5 out of 20 samples of water (25.

View Article and Find Full Text PDF