Colloids Surf B Biointerfaces
February 2025
Physicochemical modifications of biomaterials have been proposed to overcome bone integration impairment and microbial infections. The magnesium (Mg) incorporation on dental implant surfaces has shown positive results in bone-to-implant contact and in the reduction of microbial colonization. Here, we explored the potential of using different Mg precursors to synthesize coatings via plasma electrolytic oxidation (PEO) on commercially pure titanium (cpTi), aiming to optimize the surface and biological properties.
View Article and Find Full Text PDFObjectives: To characterize the surface of zirconia (Y-TZP) submitted to different surface treatments (with and without plasma associations) and to evaluate the shear bond strength (SBS) between veneering ceramic (VC) and Y-TZP after different aging methods.
Methods: 301 Y-TZP specimens were fabricated and distributed into 7 groups: C (control): no treatment; Al: airborne abrasion with 27 μm AlO particle; L: liner; P: plasma; Al + L: airborne + liner; Al + P: airborne + plasma; P + L: plasma + liner. The Y-TZP surface was characterized by SEM, EDS, AFM, surface profilometry, surface-free energy (SFE), and XRD.
J Photochem Photobiol B
April 2021
This in vivo study investigated whether the bioactivity of anodizing coating, produced by plasma electrolytic oxidation (PEO), on mini-plate in femur fracture could be improved with the association of photobiomodulation (PBM) therapy. From the 20 ovariectomized Wistar female rats, 8 were used for model characterization, and the remaining 12 were divided into four groups according to the use of PBM therapy by diode laser (808 nm; power: 100 mW; energy: 6.0 J; energy density: 212 J/cm; power density: 3.
View Article and Find Full Text PDFMater Sci Eng C Mater Biol Appl
January 2021
The treatment of polytrauma patients represents a great challenge in the maxillofacial and orthopedic surgery fields. Therefore, this study tested the hypothesis that the use of a bioactive coating (by plasma electrolytic oxidation, PEO) on titanium microplates could improve the fracture healing of low bone mineral density (BMD) rats. Thirty female rats underwent bilateral ovariectomy surgery (OVX), and 35 rats underwent fake surgery (SHAM).
View Article and Find Full Text PDFAn amendment to this paper has been published and can be accessed via a link at the top of the paper.
View Article and Find Full Text PDFObjectives: In this in vivo animal study, we evaluated the effect of plasma electrolytic oxidation (PEO) coating on the topographic and biological parameters of implants installed in rats with induced osteoporosis and low-quality bones.
Materials And Methods: In total 44 Wistar rats (Rattus novergicus), 6 months old, were submitted to ovariectomy (OXV group) and dummy surgery (SHAM group). After 90 days, the ELISA test was performed and the ovariectomy effectiveness was confirmed.
Materials (Basel)
April 2020
Plasma electrolytic oxidation (PEO) has been a promising surface coating with better mechanical and antimicrobial parameters comparing to conventional treatment surfaces. This study evaluated the peri-implant bone repair using (PEO) surface coatings compared with sandblasted acid (SLA) treatment. For this purpose, 44 Wistar rats were ovariectomized (OVX-22 animals) or underwent simulated surgery (SS-22 animals) and received implants in the tibia with each of the surface coatings.
View Article and Find Full Text PDFPurpose: To investigate the influence of nonthermal plasma (NTP) treatment on the tensile bond strength between heat-polymerized acrylic resin for ocular prostheses and silicone reliner, with and without the use of an adhesive primer.
Materials And Methods: One-hundred and sixty-four acrylic resin specimens were fabricated and randomly distributed into four groups according to the type of surface treatment: Sofreliner Primer, NTP, Sofreliner Primer + NTP, and NTP + Sofreliner Primer. Two specimens interposed with relining material (Sofreliner) formed one test sample to perform the tensile bond strength tests, before (initial) and after storage (final) in saline solution (37°C, 90 days, n = 10).
Statement Of Problem: The properties, such as softness and viscoelasticity, of a resinous reliner can deteriorate and extrinsic elements can become incorporated, making surface protection of the reliner material essential.
Purpose: The purpose of this in vitro study was to evaluate the effect of low temperature plasma on Coe-Soft resinous reliner, submitted to aging in artificial saliva for up to 180 days. Sorption, solubility, Shore A hardness, surface energy, and topographic characteristics were analyzed by scanning electronic microscopy (SEM) and energy-dispersive spectroscopy (EDS).
This manuscript reports an evaluation of the effects of simple chemical-heat treatments on the deposition of different ceramic coatings, i.e., TiO, CaTiO and CaP, on commercially pure titanium (cp-Ti) and Ti6Al4V and the influence of the coatings on cells interaction with the surfaces.
View Article and Find Full Text PDFBackground: Search for materials that may either replace titanium dental implants or constitute an alternative as a new dental implant material has been widely studied. As well, the search for optimum biocompatible metal surfaces remains crucial. So, the aim of this work is to develop an oxidized surface layer on tantalum using plasma electrolytic oxidation (PEO) similar to those existing on oral implants been marketed today.
View Article and Find Full Text PDFMater Sci Eng C Mater Biol Appl
December 2016
The effect of a photopolymerized glaze on different properties of acrylic resin (AR) for ocular prostheses submitted to accelerated aging was investigated. Forty discs were divided into 4 groups: N1 AR without glaze (G1); colorless AR without glaze (G2); N1 AR with glaze (G3); and colorless AR with glaze (G4). All samples were polished with sandpaper (240, 600 and 800-grit).
View Article and Find Full Text PDFWe report an electrochemical glucose biosensor made with layer-by-layer (LbL) films of functionalized reduced graphene oxide (rGO) and glucose oxidase (GOx). The LbL assembly using positively and negatively charged rGO multilayers represents a simple approach to develop enzymatic biosensors. The electron transport properties of graphene were combined with the specificity provided by the enzyme.
View Article and Find Full Text PDFBiofunctionalized surfaces for implants are currently receiving much attention in the health care sector. Our aims were (1) to create bioactive Ti-coatings doped with Ca, P, Si, and Ag produced by microarc oxidation (MAO) to improve the surface properties of biomedical implants, (2) to investigate the TiO2 layer stability under wear and corrosion, and (3) to evaluate human mesenchymal stem cells (hMSCs) responses cultured on the modified surfaces. Tribocorrosion and cell experiments were performed following the MAO treatment.
View Article and Find Full Text PDFIn this study, the authors tested the hypotheses that plasma electrolytic oxidation (PEO) and glow-discharge plasma (GDP) would improve the electrochemical, physical, chemical, and mechanical properties of commercially pure titanium (cpTi), and that blood protein adsorption on plasma-treated surfaces would increase. Machined and sandblasted surfaces were used as controls. Standard electrochemical tests were conducted in artificial saliva (pHs of 3.
View Article and Find Full Text PDFThe surface characteristics and electrochemical properties of bioactive coatings produced by plasma electrolytic oxidation (PEO) with calcium, phosphorous, silicon and silver on commercially pure titanium were evaluated. PEO treatment produced a porous oxide layer, which improved the surface topography, and enriched the surface chemistry with bioactive elements, responsible for mimicking bone surface. The surfaces with higher calcium concentration presented antibacterial and biocompability properties with better responses for corrosion and barrier properties, due to the presence of rutile crystalline structure.
View Article and Find Full Text PDFStatement Of Problem: Nonthermal plasma (NTP) treatment is an alternative technique for promoting the adhesion of resin cement to lithium disilicate ceramic. However, no study has evaluated whether the surface modifications are affected by atmospheric air aging.
Purpose: The purposes of this in vitro study were to characterize the lithium disilicate surface after depositing an organosilicon film with NTP treatment and to verify the surface energy before and after atmospheric air aging up to 30 days.
Dental implants, inserted into the oral cavity, are subjected to a synergistic interaction of wear and corrosion (tribocorrosion), which may lead to implant failures. The objective of this study was to investigate the tribocorrosion behavior of Ti oxide films produced by micro-arc oxidation (MAO) under oral environment simulation. MAO was conducted under different conditions as electrolyte composition: Ca/P (0.
View Article and Find Full Text PDFMater Sci Eng C Mater Biol Appl
March 2016
The effect of nonthermal plasma on the surface characteristics of commercially pure titanium (cp-Ti), and on the shear bond strength between an autopolymerizing acrylic resin and cp-Ti was investigated. A total of 96 discs of cp-Ti were distributed into four groups (n=24): Po (no surface treatment), SB (sandblasting), Po+NTP and SB+NTP (methane plasma). Surface characterization was performed through surface energy, surface roughness, scanning microscopy, energy dispersive spectroscopy, and X-ray diffraction tests.
View Article and Find Full Text PDFPurpose: The purpose of this study was twofold: 1) to characterize the zirconia (Y-TZP) surfaces through scanning electronic microscopy associated with energy-dispersive spectroscopy and atomic force microscopy after the deposition of a thin organosilicon film by nonthermal plasma (NTP) treatment, and 2) to determine the zirconia surface hydrophilicity, before and after aging, through surface energy analysis.
Materials And Methods: Surfaces of 16 zirconia disks (10 x 3 mm) were treated for 30 min each with hexamethyldisiloxane and argon plasmas, followed by oxygen plasma. Disks were analyzed before NTP treatment, immediately after NTP treatment, and after aging for 7, 15, and 30 days.
Biointerphases
December 2015
The objectives of the present study were to produce bioactive coatings in solutions containing Ca, P, and Si by plasma electrolytic oxidation (PEO) on commercially pure titanium, to investigate the influence of different electrolytes concentration and treatment duration on the produced anodic films and to evaluate biocompatibility properties. The anodic films were characterized using scanning electron microscopy, energy-dispersive spectroscopy, atomic force microscopy, and x-ray diffraction and x-ray photoelectron spectroscopies. The surface energy and roughness were also evaluated.
View Article and Find Full Text PDFPurpose: To analyze whether immersion in sodium fluoride (NaF) solutions and/or common acidic beverages (test solutions) would affect the surface roughness or topography of lithium disilicate ceramic.
Methods: 220 ceramic discs were divided into four groups, each of which was subdivided into five subgroups (n = 11). Control group discs were immersed in one of four test beverages for 4 hours daily or in artificial saliva for 21 days.
Arch Oral Biol
October 2010
Unlabelled: The adhesion of Candida albicans to surfaces is the prerequisite for occurrence of denture stomatitis.
Objective: Hence, this study investigated if surface modifications with plasma treatments could reduce the adherence of C. albicans to a denture base resin.