Background: The coronavirus disease-2019 (COVID-19) pandemic has generated enormous pressure on healthcare establishments, prompting the restructuring of services to rationalise resources. Complex head and neck reconstructive surgery in this setting may carry substantial risk to patients and staff. This paper outlines the management strategy and outcomes of major head and neck oncological cases at a single regional tertiary referral centre.
View Article and Find Full Text PDFEndogenous opioid peptides and exogenous opioids modulate immune function, and animal and human studies have shown that some have a depressant immunomodulatory effect. This is potentially of high clinical significance, eg, in cancer patients and surgery. The primary objective of this pilot study was to evaluate the effect of morphine and oxycodone on immune pathways associated with immunosuppression in gynecological laparotomy patients.
View Article and Find Full Text PDFObjective: A reliable, continuous method of monitoring splanchnic organ oxygen saturation could allow for the early detection of malperfusion, and may prevent the onset of multiple organ failure. Current monitoring techniques have not been widely accepted in critical care monitoring. As a preliminary to developing a continuous indwelling device, this study evaluates a new handheld fiber optic photoplethysmographic (PPG) sensor for estimating the blood oxygen saturation (SpO(2)) of splanchnic organs during surgery.
View Article and Find Full Text PDFBackground: The continuous monitoring of splanchnic organ oxygen saturation could make the early detection of inadequate tissue oxygenation feasible, reducing the risk of hypoperfusion, severe ischemia, multiple organ failure, and, ultimately, death. Current methods for assessing splanchnic perfusion have not been widely accepted for use in the clinical care environment. In an attempt to overcome the limitations of the current techniques, a new fiberoptic photoplethysmographic (PPG)/pulse oximetry sensor was developed as a means of assessing splanchnic organ perfusion during surgery in humans.
View Article and Find Full Text PDFSplanchnic organs are particularly vulnerable to hypoperfusion. Currently, there is no technique that allows for the continuous estimation of splanchnic blood oxygen saturation (SpO(2)). As a preliminary to developing a suitable splanchnic SpO(2) sensor, a new reflectance fiber optic photoplethysmographic (PPG) sensor and processing system are developed.
View Article and Find Full Text PDF