The purpose of this work is to theoretically and experimentally investigate the applicability of the Tsai-Hill failure criterion and classical laminate theory for predicting the strength and stiffness of 3D-printed polylactide laminate composites with various raster angles in mechanical tests for uniaxial tension and compression. According to the results of tensile and compression tests, the stiffness matrix components of the orthotropic individual lamina and strength were determined. The Poisson's ratio was determined using the digital image correlation method.
View Article and Find Full Text PDFStability and narrow size distribution are among the main requirements that apply to drug formulations based on polymeric nanoparticles. In this study, we obtained a series of particles based on biodegradable poly(D,L-lactide)--poly(ethylene glycol) (P(D,L)LA--PEG) copolymers with varied hydrophobic P(D,L)LA block length from 50 to 1230 monomer units stabilized by poly(vinyl alcohol) (PVA) by a simple "oil-in-water" emulsion method. We found that nanoparticles of P(D,L)LA--PEG copolymers with relatively short P(D,L)LA block ( ≤ 180) are prone to aggregate in water.
View Article and Find Full Text PDFThe kinetic of D,L-lactide polymerization in presence of biocompatible zirconium acetylacetonate initiator was studied by differential scanning calorimetry in isothermal mode at various temperatures and initiator concentrations. The enthalpy of D,L-lactide polymerization measured directly in DSC cell was found to be =-17.8±1.
View Article and Find Full Text PDFMater Sci Eng C Mater Biol Appl
July 2020
Biodegradable poly(l-lactide)/calcium phosphate composites are promising materials for fabrication of bone fixation implants with improved properties. Multistage compounding was proposed as an efficient method for the preparation of biodegradable poly(l-lactide)/calcium phosphate composites with submicron filler dispersion and mechanical characteristics similar to native bone. The improvement of the characteristics is caused both by the filler itself and by the increase of polymer crystallinity due to the nucleation effect.
View Article and Find Full Text PDFThe monitoring of degradation processes' kinetics in polymers is one of the attractive possibilities of ultrasound technique applications that provide non-destructive imaging of polymers' internal microstructure and measurements of elastic properties. In this work, biodegradable polymers and copolymers based on L,L-lactide, D,L-lactide and ε-caprolactone have been studied at different stages of hydrolysis at 37 °C by high-frequency (100 and 200 MHz) ultrasound. The acoustic microscopy technique has been developed to reveal changes in the internal microstructure and bulk sound speed in polymer samples over a hydrolysis period of 25 weeks.
View Article and Find Full Text PDFACS Appl Mater Interfaces
October 2017
Uniaxial tension accompanied by the orientation and crystallization of polymer chains is one of the powerful methods for the improvement of mechanical properties. Crystallization of amorphous isotropic polylactide (PLA) at room temperature is studied for the first time during the drawing of films in the presence of liquid adsorption-active media (ethanol, water-ethanol mixtures, and n-heptane) by the solvent crazing mechanism. The crystalline structure arises only under simultaneous actions of a liquid medium and a tensile stress and does not depend on the nature of the environment.
View Article and Find Full Text PDF