Publications by authors named "Nicole R Marques"

Objective: Identifying fluid responsiveness is critical to optimizing perfusion while preventing fluid overload. An experimental study of hypovolemic shock resuscitation showed the importance of ventricular compliance and peripheral venous pressure (PVP) on fluid responsiveness. The authors tested the hypothesis that reduced ventricular compliance measured using transesophageal echocardiography results in decreased fluid responsiveness after a fluid bolus.

View Article and Find Full Text PDF

Background: Intravascular air embolism (AE) is a preventable but potentially catastrophic complication caused by intravenous tubing, trauma, and diagnostic and surgical procedures. The potentially fatal risks of arterial AE are well-known, and emerging evidence demonstrates impact of venous AEs on inflammatory response and coagulation factors. A novel FDA-approved in-line air detection and purging system was used to detect and remove air caused by administering a rapid fluid bolus during surgery.

View Article and Find Full Text PDF

To determine the effectiveness of colonic fluid absorption as a route for fluid resuscitation of a major burn. In order to assess the feasibility and performance of colonic resuscitation, the authors compared plasma volume expansion and hemodynamic parameters of animals submitted to colonic or intravenous fluid resuscitation. Twelve anesthetized swine were submitted to a 40% full thickness flame burn.

View Article and Find Full Text PDF

In this paper we describe a data set of multivariate physiological measurements recorded from conscious sheep ( = 8; 37.4 ± 1.1 kg) during hemorrhage.

View Article and Find Full Text PDF

Background: Sepsis, trauma, and burn injury acutely depress systolic and diastolic cardiac function; data on long-term cardiac sequelae of pediatric critical illness are sparse. This study evaluated long-term systolic and diastolic function, myocardial fibrosis, and exercise tolerance in survivors of severe pediatric burn injury.

Methods: Subjects at least 5 years after severe burn (post-burn:PB) and age-matched healthy controls (HC) underwent echocardiography to quantify systolic function (ejection fraction[EF%]), diastolic function (E/e'), and myocardial fibrosis (calibrated integrated backscatter) of the left ventricle.

View Article and Find Full Text PDF

Background: Vasopressors provide a rapid and effective approach to correct hypotension in the perioperative setting. Our group developed a closed-loop control (CLC) system that titrates phenylephrine (PHP) based on the mean arterial pressure (MAP) during general anesthesia. As a means of evaluating system competence, we compared the performance of the automated CLC with physicians.

View Article and Find Full Text PDF

Background: Hemorrhagic shock is the leading cause of trauma-related death in the military setting. Definitive surgical treatment of a combat casualty can be delayed and life-saving fluid resuscitation might be necessary in the field. Therefore, improved resuscitation strategies are critically needed for prolonged field and en route care.

View Article and Find Full Text PDF

Unlabelled: Pulmonary injury can be characterized by an increased need for fraction of inspired oxygen or inspired oxygen percentage (FiO2) to maintain arterial blood saturation of oxygenation (SaO2). We tested a smart oxygenation system (SOS) that uses the activity of a closed-loop control FiO2 algorithm (CLC-FiO2) to rapidly assess acute respiratory distress syndrome (ARDS) severity so that rescue ventilation (RscVent) can be initiated earlier. After baseline data, a pulse-oximeter (noninvasive saturation of peripheral oxygenation [SpO2]) was placed.

View Article and Find Full Text PDF

Physiological compensatory mechanisms can mask the extent of hemorrhage in conscious mammals, which can be further complicated by individual tolerance and variations in hemorrhage onset and duration. We assessed the effect of hemorrhage rate on tolerance and early physiologic responses to hemorrhage in conscious sheep. Eight Merino ewes (37.

View Article and Find Full Text PDF

Automated critical care systems for en route care will rely heavily on noninvasive continuous monitoring. It has been reported that noninvasive assessment of blood hemoglobin via CO-oximetry (SpHb) assessed by spot measurements lacks sufficient accuracy for clinical decision making in trauma patients. However, the precision and utility of trending of continuous hemoglobin have not been evaluated in hemorrhaging humans.

View Article and Find Full Text PDF

Objective: To determine if passive leg raising (PLR) significantly increases cardiac output in a cohort of healthy pregnant women during the third trimester.

Study Design: Using a noninvasive monitor, baseline hemodynamic measurements for arterial blood pressure, systolic and diastolic blood pressure, heart rate, cardiac output, cardiac index, stroke volume, and systemic vascular resistances were obtained with patients in the semirecumbent position. Measurements were repeated after a 3-minute PLR maneuver in supine, right lateral decubitus, and left lateral decubitus positions.

View Article and Find Full Text PDF

Purpose: To evaluate the effects of intraluminal injection of glutamine on the serum trolox equivalent antioxidant capacity in an experimental model of ischemia-reperfusion of the liver observing the applicability of modifications on the original assay method.

Methods: Thirty Wistar rats underwent laparotomy to perform a 20 cm blind sac of small bowel and occlusion of the hepatic hilo for 30 minutes and reperfusion for 5 minutes. Into the gut sac it was injected glutamine (glutamine group, n=10) or distilled water (control group, n=10).

View Article and Find Full Text PDF