Publications by authors named "Nicolas Dehaynin"

Background: This work aimed to determine the optimum VOLO Ultra algorithm parameters for tomotherapy treatments.

Methods: 1056 treatment plans were generated with VOLO Ultra for 36 patients and six anatomical locations. The impact of varying four parameters was studied: the accelerated treatment (AT), leaf open/close time (LOT) cutoff, normal tissue objective (NTO) weight, and number of iterations.

View Article and Find Full Text PDF

Left-sided breast cancer radiotherapy can lead to late cardiovascular complications, including ischemic events. To mitigate these risks, cardiac-sparing techniques such as deep-inspiration breath-hold (DIBH) and intensity-modulated radiotherapy (IMRT) have been developed. However, recent studies have shown that mean heart dose is not a sufficient dosimetric parameter for assessing cardiac exposure.

View Article and Find Full Text PDF

Background: Adaptive radiotherapy (ART) has the potential to reduce the toxicities of radiotherapy and improve overall survival by considering variations in the patient's anatomy during the course of treatment. ART's first commercial solutions are now implemented in clinical radiotherapy departments. However, before they can be used safely with real patients, these solutions must be rigorously evaluated to precisely determine the limits of their use.

View Article and Find Full Text PDF

Purpose: To show the usefulness of topographic 2D megavoltage images (MV2D) for the localization of breast cancer patients treated with TomoDirect (TD), a radiotherapy treatment technique with fixed-angle beams performed on a TomoTherapy system.

Methods: A method was developed to quickly localize breast cancer patients treated with TD by registering the MV2D images produced before a TD treatment with reference images reconstructed from a kilovoltage CT simulation scanner and by using the projection of the beam-eye-view TD treatment field. Dose and image quality measurements were performed to determine the optimal parameters for acquiring MV2D images.

View Article and Find Full Text PDF

The peripheral dose distribution is a growing concern for the improvement of new external radiation modalities. Secondary particles, especially photo-neutrons produced by the accelerator, irradiate the patient more than tens of centimeters away from the tumor volume. However the out-of-field dose is still not estimated accurately by the treatment planning softwares.

View Article and Find Full Text PDF

Background And Purpose: TomoDirect (TD) can only operate in free-breathing. The purpose of this study is to compare TD with breath-hold 3D conformal radiotherapy (3DCRT) and intensity modulated radiotherapy (IMRT) techniques for left breast treatments, and to determine if the lack of respiratory gating is a handicap for cardiac sparing.

Materials And Methods: 15 patients treated for left breast had two computed tomography simulation, in free breathing (FB) and in deep-inspiration breath-hold (DIBH).

View Article and Find Full Text PDF

Background And Purpose: To determine the optimum combination of treatment parameters between pitch, field width (FW) and modulation factor (MF) for extremity sarcomas in tomotherapy.

Materials And Methods: Six patients previously treated for extremity sarcomas (3 arms and 3 legs) with tomotherapy were included in this study. 288 treatment plans were recalculated, corresponding to all combinations between 2 FW (2.

View Article and Find Full Text PDF