Objective: The use of steerable sheaths to allow total transfemoral access (TFA) of branched endovascular repair (BEVAR) of thoracoabdominal aortic aneurysms has been proposed as an alternative to upper extremity access (UEA); however, multicenter results from high-volume aortic centers are lacking.
Materials And Methods: The Total Transfemoral Branched Endovascular Thoracoabdominal Aortic Repair (TORCH2) study is a physician-initiated, national, multicenter, retrospective, observational registry (Clinicaltrials.gov identifier: NCT04930172) of patients undergoing BEVAR with a TFA for the cannulation of reno-visceral target vessels (TV).
Aortic dissection is a life-threatening vascular disease associated with high rates of morbidity and mortality, especially in medically underserved communities. Understanding patients' blood flow patterns is pivotal for informing evidence-based treatment as they greatly influence the disease outcome. The present study investigates the flow patterns in the false lumen of three aorta dissections (fully perfused, partially thrombosed, and fully thrombosed) in the chronic phase, and compares them to a healthy aorta.
View Article and Find Full Text PDFRFA is a relatively new treatment, approved by the FDA in 1999 and is a minimally invasive intervention that has become one of the most common alternatives due to its many advantages, including decreased pain, less morbidity, shorter hospital stay and faster return to work. We retrospectively analyzed a total of 503 limbs submitted for surgical interventions for VVs using the RFA, combined or not with surgical phlebectomies and sclerotherapy, in our institution between April 2012 and December 2020. The technical success was 99.
View Article and Find Full Text PDFBackground: Arch pathology represents one of the last frontiers in aortic aneurysm endovascular management. Several companies recently developed dedicated branched and fenestrated endografts specifically designed for the aortic arch, aiming to overcome some of the issues associated with standard thoracic endograft and supra-aortic vessels extra-anatomic debranching. This study aimed to evaluate early outcomes obtained with a custom-made fenestrated endograft approved for thoracic aortic aneurysms exclusion.
View Article and Find Full Text PDFCurr Pharm Des
March 2023
Introduction: The aim of the present study is to report the outcome of patients presenting an isolated type II endoleak (TIIEL) requiring reintervention and to identify clinical and anatomical characteristics potentially implicated in refractory TIIEL occurrence and fate. Materials and Methods: A multicenter retrospective study on TIIEL requiring reintervention was conducted between January 2003 and December 2020. Demographic and clinical characteristics, procedural technical aspects, reinterventions, and outcomes were recorded.
View Article and Find Full Text PDFObjectives: To assess the outcomes of Cook t-Branch off-the-shelf multibranched stent graft in the treatment of complex aortic aneurysms with narrow internal aortic lumen.
Methods: Between 2016 and 2020, 48 patients (mean age, 73 years) underwent elective or urgent or emergent Cook t-Branch implantation for thoracoabdominal or para/juxtarenal aortic aneurysms in two Italian vascular centers. Among these, 20 patients presented a paravisceral or pararenal luminal diameter of less than 25 mm.
Objective: In recent years, manufacturers have developed new stent grafts with lower profiles to increase the endovascular aneurysm repair applicability. As reported by the current European Society for Vascular Surgery guidelines, long-term evaluation of such low-profile platforms is strongly recommended. This study aims to report outcomes beyond 5 years from a multicenter registry, including a real-world cohort of patients electively treated with low-profile stent grafts.
View Article and Find Full Text PDFEur J Vasc Endovasc Surg
August 2021
Objective: The Gore Excluder Iliac Branch Endoprosthesis (IBE) was developed to preserve perfusion in the hypogastric artery after endovascular repair of aorto-iliac aneurysms. This study reports the 12 month technical and clinical outcomes of treatment with this device.
Methods: This study was a physician initiated international multicentre, prospective cohort study.
Objective: To assess the initial clinical experience with a novel endograft system (NEXUS Aortic Arch Stent Graft System) designed to treat aortic arch pathologies and address the morphology and hemodynamic challenges of the aortic arch.
Summary Background Data: The aortic arch remains the most challenging part of the aorta for both open and endovascular repair. Transcatheter aortic arch repair has the potential to significantly reduce surgical risks.
Small-sized vessels can represent a contraindication to standard endovascular aortic repair (EVAR), and more specifically, aortoiliac deformities resulting from poliomyelitis may add an adjunctive challenge for total endovascular repair. Herein we report a case of a 62-year-old man with a 55 mm abdominal aortic aneurysm (AAA) and a history of poliomyelitis. More specifically, a computed tomography angiogram (CTA) showed a very narrow infrarenal aortic neck, measuring 13 mm in maximum diameter, and severely atrophic external iliac and common femoral arteries.
View Article and Find Full Text PDFObjective: The aim was to describe the outcomes of the Anaconda™ Fenestrated endograft Italian Registry for complex aortic aneurysms (AAAs), unsuitable for standard endovascular aneurysm repair (EVAR).
Methods: Between 2012 and 2018 patients with a proximal neck unsuitable for standard EVAR, treated with the fenestrated Anaconda™ endograft, were prospectively enrolled in a dedicated database. Endpoints were peri-operative technical success (TS) and evaluation of type Ia/b or 3 endoleaks (T1/3 EL), target visceral vessel (TVV) occlusion, re-interventions, and AAA related mortality at 30 days, six months, and later follow up.
Objective: The objective of this prospective single centre study was to assess whether branches and fenestrations have different outcomes on renal function in the early phase.
Methods: From March 2018 to June 2019, 67 patients who underwent elective fenestrated and branched endovascular aneurysm repair (F/BEVAR) procedures were enrolled in this study. The patients were divided into two groups according to the renal bridging component configuration (fenestration vs.
J Vasc Surg Cases Innov Tech
December 2019
A 66-year-old man arrived at our emergency department 3 years after an endovascular aneurysm sealing procedure performed at another center. Computed tomography angiography showed distal migration of a Nellix endoprosthesis (Endologix, Irvine, Calif) and a posterior contained rupture. The left kidney was excluded by an occluded iliac-left renal bypass, which was performed at the time of the Nellix implantation because of unintended coverage.
View Article and Find Full Text PDFAims: The aim of this study was to report the 30-day technical and clinical success with endovascular repair using the ultra-low-profile Ovation stent graft in patients judged to be outside the instructions for use (IFU) for conventional endografts, while amenable to treatment within the IFU for Ovation.
Methods And Results: One hundred and twenty-two patients (78.65±7.
Objective: Although the long-term results of endovascular aortic repair (EVAR) with low-profile devices in patients with hostile iliac anatomies have been published, there are no reported results specifically for narrow aortic bifurcations (NAB). This study investigated the outcomes of EVAR with the INCRAFT device in NAB (<16 mm).
Methods: This multicenter retrospective study involved five vascular surgery centers.
Background: The aim of this study is to assess our experience and mid-term outcomes using Jetstream atherectomy system for treatment of femoropopliteal artery disease (FPAD).
Methods: Data of 30 patients with FPAD treated at our center between 2013 and 2016 were analyzed. Two subgroups of patients were identified: Group A included patients (n = 18) with de novo lesions; Group B (n = 12) included those with in-stent restenosis.
Background: The aim of this study is to report the Destino-guided branched endovascular aortic repair approach as a valid alternative to catheterization downward branches in complex aortic arch/descending thoracic anatomies.
Methods & Results: A 53-year-old woman with Marfan syndrome underwent a thoracoabdominal aortic aneurysm (TAAA) repair for a type III dissecting aneurysm. A custom repair with an endograft having 3 fenestrations (for renal arteries and superior mesenteric artery) and 1 branch for the celiac trunk was planned.
Background: The aim of this work is describing incidence and fate of type 2 endoleaks (T2ELs) in a multicentric cohort of patients treated by endovascular aneurysms repair using the Ovation device (Endologix) and comparing them with a group treated using the Excluder (W. L. Gore & Associates).
View Article and Find Full Text PDFObjective: Staged endovascular treatment of thoracoabdominal aortic aneurysms (TAAAs) with temporary perfusion of the sac through a branch left unstented or a dedicated branch is a strategy intended to reduce the risk of postoperative spinal cord ischemia (SCI). However, potential complications of this approach are aneurysm sac progression between stages, visceral embolism, and occlusion or displacement of components. We here present the "bare branch" technique, a safe adjunct to TAAA repair in terms of interstage complications.
View Article and Find Full Text PDFObjective: The objective of this study was to assess immediate and midterm outcomes for urgent/emergent and elective patients with thoracoabdominal aortic aneurysms (TAAAs) treated with the first commercially available "off-the-shelf" multibranched endograft for endovascular aneurysm repair, with a single-step or a staged surgical approach.
Methods: A multicenter, nonrandomized, retrospective study was conducted of TAAA patients grouped by urgent/emergent and elective treatment with multibranched endograft for endovascular aneurysm repair at 13 Italian centers from November 2012 to August 2016. Urgent/emergent repair was classified as rupture in 16%, impending rupture in 9%, pain in 53%, or a maximum TAAA diameter ≥80 mm in 22%.