Publications by authors named "Nico Lanconelli"

Aim: The present work concerns the comparison of the performances of three systems for dosimetry in RPT that use different techniques for absorbed dose calculation (organ-level dosimetry, voxel-level dose kernel convolution and Monte Carlo simulations). The aim was to assess the importance of the choice of the most adequate calculation modality, providing recommendations about the choice of the computation tool.

Methods: The performances were evaluated both on phantoms and patients in a multi-level approach.

View Article and Find Full Text PDF

Aim: To compare the efficacy of cord blood and peripheral adult donor blood serum eyedrops, controlled for growth factor content, in the treatment of severe dry eye diseases (DED) resistant to conventional therapy.

Methods: This was a multicentre randomised, double-masked, cross-over clinical trial. Sixty patients diagnosed as severe DED, associated to persistent corneal epithelial defects were randomised and equally assigned to group A (treated with cord blood serum (CBS)) or group B (treated with PBS), eyedrops administered eight times/day for 1 month.

View Article and Find Full Text PDF

Background: At present activity quantification is one of the most critical step in dosimetry calculation, and Partial Volume Effect (PVE) one of the most important source of error. In recent years models based upon phantoms that incorporate hot spheres have been used to establish recovery models. In this context the goal of this study was to point out the most critical issues related to PVE and to establish a model closer to a biological imaging environment.

View Article and Find Full Text PDF

This article aims to present the protocol on Quality Controls in Digital Mammography published online in 2015 by the European Federation of Organisations for Medical Physics (EFOMP) which was developed by a Task Force under the Mammo Working Group. The main objective of this protocol was to define a minimum set of easily implemented quality control tests on digital mammography systems that can be used to assure the performance of a system within a set and acceptable range. Detailed step-by-step instructions have been provided, limiting as much as possible any misinterpretations or variations by the person performing.

View Article and Find Full Text PDF

Background And Purpose: In this study we attempt to automatically classify individual patients with different parkinsonian disorders, making use of pattern recognition techniques to distinguish among several forms of parkinsonisms (multi-class classification), based on a set of binary classifiers that discriminate each disorder from all others.

Methods: We combine diffusion tensor imaging, proton spectroscopy and morphometric-volumetric data to obtain MR quantitative markers, which are provided to support vector machines with the aim of recognizing the different parkinsonian disorders. Feature selection is used to find the most important features for classification.

View Article and Find Full Text PDF

Purpose And Objective: Propose a novel method for individualized selection of beam angles and treatment isocenter in tangential breast intensity modulated radiation therapy (IMRT).

Methods And Materials: For each patient, beam and isocenter selection starts with the fully automatic generation of a large database of IMRT plans (up to 847 in this study); each of these plans belongs to a unique combination of isocenter position, lateral beam angle, and medial beam angle. The imposed hard planning constraint on patient maximum dose may result in plans with unacceptable target dose delivery.

View Article and Find Full Text PDF

Purpose: To develop a fully automated procedure for multicriterial volumetric modulated arc therapy (VMAT) treatment planning (autoVMAT) for stage III/IV non-small cell lung cancer (NSCLC) patients treated with curative intent.

Materials And Methods: After configuring the developed autoVMAT system for NSCLC, autoVMAT plans were compared with manually generated clinically delivered intensity-modulated radiotherapy (IMRT) plans for 41 patients. AutoVMAT plans were also compared to manually generated VMAT plans in the absence of time pressure.

View Article and Find Full Text PDF

The aim of this study is to determine, via measurements on phantoms and Monte Carlo (MC) simulations, the dose distribution of absorbed dose in a cone-beam breast computed tomography scan. The absorbed dose volume distribution was measured inside a polyethylene cylindrical phantom, simulating adipose breast tissue, using LiF:Mg,Ti thermoluminescence dosimeters. A reasonable agreement (between 2 and 8%) between the simulated and measured data was observed.

View Article and Find Full Text PDF

This study compares 3D dose distributions obtained with voxel S values (VSVs) for soft tissue, calculated by several methods at their current state-of-the-art, varying the degree of image blurring. The methods were: 1) convolution of Dose Point Kernel (DPK) for water, using a scaling factor method; 2) an analytical model (AM), fitting the deposited energy as a function of the source-target distance; 3) a rescaling method (RSM) based on a set of high-resolution VSVs for each isotope; 4) local energy deposition (LED). VSVs calculated by direct Monte Carlo simulations were assumed as reference.

View Article and Find Full Text PDF

Purpose: In this paper, the authors present a free software for assisting users in achieving the physical characterization of x-ray digital systems and image quality checks.

Methods: The program was developed as a plugin of a well-known public-domain suite ImageJ. The software can assist users in calculating various physical parameters such as the response curve (also termed signal transfer property), modulation transfer function (MTF), noise power spectra (NPS), and detective quantum efficiency (DQE).

View Article and Find Full Text PDF

Purpose: To investigate the dosimetric impact of intrafraction prostate motion and the effect of robot correction strategies for hypofractionated CyberKnife treatments with a simultaneously integrated boost.

Methods And Materials: A total of 548 real-time prostate motion tracks from 17 patients were available for dosimetric simulations of CyberKnife treatments, in which various correction strategies were included. Fixed time intervals between imaging/correction (15, 60, 180, and 360 seconds) were simulated, as well as adaptive timing (ie, the time interval reduced from 60 to 15 seconds in case prostate motion exceeded 3 mm or 2° in consecutive images).

View Article and Find Full Text PDF

Purpose: A characterization of a clinical unit for digital radiography (FUJIFILM FDR D-EVO) is presented. This system is based on the irradiation side sampling (ISS) technology and can be equipped with two different scintillators: one traditional gadolinium-oxysulphide phosphor (GOS) and a needle structured cesium iodide (CsI) phosphor panel.

Methods: The characterization was achieved in terms of response curve, modulation transfer function (MTF), noise power spectra (NPS), detective quantum efficiency (DQE), and psychophysical parameters (contrast-detail analysis with an automatic reading of CDRAD images).

View Article and Find Full Text PDF

In a recent paper, we have published a new algorithm, designated 'iCycle', for fully automated multi-criterial optimization of beam angles and intensity profiles. In this study, we have used this algorithm to investigate the relationship between plan quality and the extent of the beam direction search space, i.e.

View Article and Find Full Text PDF

Cone-beam breast Computed Tomography (bCT) is an X-ray imaging technique for breast cancer diagnosis, in principle capable of delivering a much more homogeneous dose spatial pattern to the breast volume than conventional mammography, at dose levels comparable to two-view mammography. We present an investigation of the three-dimensional dose distribution for a cone-beam CT system dedicated to breast imaging. We employed Monte Carlo simulations for estimating the dose deposited within a breast phantom having a hemiellipsoidal shape placed on a cylinder of 3.

View Article and Find Full Text PDF

Purpose: In cone-beam computed tomography (CBCT), and in particular in cone-beam breast computed tomography (CBBCT), an important issue is the reduction of the image artifacts produced by photon scatter and the reduction of patient dose. In this work, the authors propose to apply the detector displacement technique (also known as asymmetric detector or "extended view" geometry) to approach this goal. Potentially, this type of geometry, and the accompanying use of a beam collimator to mask the unirradiated half-object in each projection, permits some reduction of radiation dose with respect to conventional CBBCT and a sizeable reduction of the overall amount of scatter in the object, for a fixed contrast-to-noise ratio (CNR).

View Article and Find Full Text PDF

Purpose: The purpose of this study is to compare digital radiography systems using the metric effective detective quantum efficiency (eDQE), which better reflects digital radiography imaging system performance under clinical operating conditions, in comparison with conventional metrics such as modulation transfer function (MTF), normalized noise power spectra (NNPS), and detective quantum efficiency (DQE).

Methods: The eDQE was computed by the calculation of the MTF, the NNPS, the phantom attenuation and scatter, and estimation of x-ray flux. The physical characterization of the systems was obtained with the standard beam conditions RQA5 and RQA9, using the PA Chest phantom proposed by AAPM Report # 31 simulating the attenuation and scatter characteristics of the adult human thorax.

View Article and Find Full Text PDF

Purpose: Here, we present a physical and psychophysical characterization of a new clinical unit (named AcSelerate) for digital radiography based on a thick a-Se layer. We also compared images acquired with and without a software filter (named CRF) developed for reducing sharpness and noise of the images and making them similar to images coming from traditional computed radiography systems.

Methods: The characterization was achieved in terms of physical figures of merit [modulation transfer function (MTF), noise power spectra (NPS), detective quantum efficiency (DQE)], and psychophysical parameters (contrast-detail analysis with an automatic reading of CDRAD images).

View Article and Find Full Text PDF

Purpose: In this study, five different units based on three different technologies-traditional computed radiography (CR) units with granular phosphor and single-side reading, granular phosphor and dual-side reading, and columnar phosphor and line-scanning reading-are compared in terms of physical characterization and contrast detail analysis.

Methods: The physical characterization of the five systems was obtained with the standard beam condition RQA5. Three of the units have been developed by FUJIFILM (FCR ST-VI, FCR ST-BD, and FCR Velocity U), one by Kodak (Direct View CR 975), and one by Agfa (DX-S).

View Article and Find Full Text PDF

Purpose: In recent years, many approaches have been investigated on the development of full-field digital mammography detectors and implemented in practical clinical systems. Some of the most promising techniques are based on flat panel detectors, which, depending on the mechanism involved in the x-ray detection, can be grouped into direct and indirect flat panels. Direct detectors display a better spatial resolution due to the direct conversion of x rays into electron-hole pairs, which do not need an intermediate production of visible light.

View Article and Find Full Text PDF

In this work, gray-scale invariant ranklet texture features are proposed for false positive reduction (FPR) in computer-aided detection (CAD) of breast masses. Two main considerations are at the basis of this proposal. First, false positive (FP) marks surviving our previous CAD system seem to be characterized by specific texture properties that can be used to discriminate them from masses.

View Article and Find Full Text PDF

The recent development of new gamma imagers based on scintillation array with high spatial resolution, has strongly improved the possibility of detecting sub-centimeter cancer in Scintimammography. However, Compton scattering contamination remains the main drawback since it limits the sensitivity of tumor detection. Principal component image analysis (PCA), recently introduced in scintimam nographic imaging, is a data reduction technique able to represent the radiation emitted from chest, breast healthy and damaged tissues as separated images.

View Article and Find Full Text PDF

The purpose of this study was to perform a complete evaluation of three pieces of clinical digital mammography equipment. Image quality was assessed by performing physical characterization and contrast-detail (CD) analysis. We considered three different FFDM systems: a computed radiography unit (Fuji "FCR 5000 MA") and two flat-panel units, the indirect conversion a-Si based GE "Senographe 2000D" and the direct conversion a-Si based IMS "Giotto Image MD.

View Article and Find Full Text PDF

In this work, we present a novel approach to mass detection in digital mammograms. The great variability of the appearance of masses is the main obstacle to building a mass detection method. It is indeed demanding to characterize all the varieties of masses with a reduced set of features.

View Article and Find Full Text PDF