The purpose of this study was to develop a laboratory developed test (LDT) for HSV1/2 and VZV to run on fully automated Hologic Panther Fusion® System. The Panther Fusion System is a fully automated walkaway system, providing end-to-end workflow from sample input to DNA/RNA extraction, amplification, automated analysis, and reporting to a laboratory information system (LIS). The LDT was developed and validated on 230 clinical and 20 reference samples (n = 250) and compared to a commercially available kit.
View Article and Find Full Text PDFEffect-directed analysis (EDA) has shown its added value for the detection and identification of compounds with varying toxicological properties in water quality research. However, for routine toxicity assessment of multiple toxicological endpoints, current EDA is considered labor intensive and time consuming. To achieve faster EDA and identification, a high-throughput (HT) EDA platform, coupling a downscaled luminescent Ames and cell-based reporter gene assays with a high-resolution fraction collector and UPLC-QTOF MS, was developed.
View Article and Find Full Text PDFWe describe the development of a high-resolution, noncontact fraction collector for liquid chromatography (LC) separations, allowing high-resolution fractionation in high-density well plates. The device is based on a low-dead-volume solenoid valve operated at 1-30 Hz for accurate collection of fractions of equal volume. The solenoid valve was implemented in a modified autosampler resulting in the so-called FractioMate fractionator.
View Article and Find Full Text PDFThis study aimed at demonstrating that effect-based monitoring with passive sampling followed by toxicity profiling is more protective and cost-effective than the current chemical water quality assessment strategy consisting of compound-by-compound chemical analysis of selected substances in grab samples. Passive samplers were deployed in the Dutch river delta and in WWTP effluents. Their extracts were tested in a battery of bioassays and chemically analyzed to obtain toxicity and chemical profiles, respectively.
View Article and Find Full Text PDFEffect-directed analysis (EDA) is a commonly used approach for effect-based identification of endocrine disruptive chemicals in complex (environmental) mixtures. However, for routine toxicity assessment of, for example, water samples, current EDA approaches are considered time-consuming and laborious. We achieved faster EDA and identification by downscaling of sensitive cell-based hormone reporter gene assays and increasing fractionation resolution to allow testing of smaller fractions with reduced complexity.
View Article and Find Full Text PDFThe Salmonella reversion based Ames test is the most widely used method for mutagenicity testing. For rapid toxicity assessment of e.g.
View Article and Find Full Text PDFThe AR-EcoScreen is a widely used reporter assay for the detection of androgens and anti-androgens. Endogenous expression of glucocorticoid receptors and their affinity for the androgen responsive element that drives reporter expression, however, makes the reporter cells sensitive to interference by glucocorticoids and less specific for (anti-)androgens. To create a glucocorticoid insensitive derivative of the AR-EcoScreen, CRISPR/Cas9 genome editing was used to develop glucocorticoid receptor knockout mutants by targeting various sites in the glucocorticoid gene.
View Article and Find Full Text PDFWe describe the development and evaluation of a GC-MS fractionation platform that combines high-resolution fraction collection of full chromatograms with parallel MS detection. A y-split at the column divides the effluent towards the MS detector and towards an inverted y-piece where vaporized trap solvent is infused. The latter flow is directed outside the GC oven allowing subsequent condensation and stepwise collection of liquid fractions with trapped analytes on a 384-well plate.
View Article and Find Full Text PDFBioassays are particularly useful tools to link the chemical and ecological assessments in water quality monitoring. Different methods cover a broad range of toxicity mechanisms in diverse organisms, and account for risks posed by non-target compounds and mixtures. Many tests are already applied in chemical and waste assessments, and stakeholders from the science-police interface have recommended their integration in regulatory water quality monitoring.