Microfabrication advances have resulted in small, cheap, and precise devices for biological microelectromechanical systems (bioMEMS). SU-8/SU-8 2000 is an attractive material for these applications because of its high-aspect ratio fabrication capability, dielectric properties, and thermochemical stability. Despite these advantages, the potential toxicity of SU-8 2000 may limit its use in cell-based applications.
View Article and Find Full Text PDFThis work demonstrated the design, fabrication, packaging, and characterization of an active microscaffold system with fluid perfusion/nutrient delivery functionalities for culturing in vitro neuronal networks from dissociated hippocampal rat pup neurons. The active microscaffold consisted of an 8 x 8 array of hollow, microfabricated, SU-8 towers (1.0 mm or 1.
View Article and Find Full Text PDF