Background: Increased longevity in patients with congenital heart disease (CHD) is associated with late complications, mainly heart failure, which may not be amenable to redo surgery and become refractory to medical therapy and so, trigger referral for transplantation. We assessed the current role and future prospects of heart and heart-lung transplantation for patients with CHD in England.
Methods: We performed a retrospective analysis of hospital episodes for England for 1997-2015, identifying patients with a CHD code (ICD-10 'Q2xx.
Interact Cardiovasc Thorac Surg
April 2019
Objectives: Left ventricular assist devices are funded in the UK exclusively as a bridge to transplant (BTT). However, patients who potentially could receive a transplant may develop reversible contraindications to transplant. Bridge to candidacy (BTC) has sometimes been controversial, given the uncertain clinical efficacy of BTC and the risk that reimbursement could be denied.
View Article and Find Full Text PDFObjective: To study the survival and patient outcome in a population of UK patients supported by an implantable left ventricular assist device (LVAD) as a bridge to heart transplantation.
Methods: Data on all adult patients (n=342) who received a HeartMate II or HVAD as a first long-term LVAD between January 2007 and 31 December 2013 were extracted from the UK Ventricular Assist Device (VAD) Database in November 2015. Outcomes analysed include survival on a LVAD, time to urgent listing, heart transplantation and complications including those needing a pump exchange.
Background: Heart transplantation (HTx) remains the most effective long-term treatment for advanced heart failure. Primary graft dysfunction (PGD) continues to be a potentially life-threatening early complication. In 2014, a consensus statement released by International Society for Heart and Lung Transplantation (ISHLT) established diagnostic criteria for PGD.
View Article and Find Full Text PDFAims: The need for right ventricular assist device (RVAD) support after left ventricular assist device (LVAD) therapy is associated with increased morbidity and mortality. We used 2D echocardiographic strain analysis to assess right atrial (RA) and right ventricular (RV) mechanics and predict the need for RV mechanical support after LVAD implantation.
Methods And Results: Seventy advanced chronic heart failure (ACHF) patients [59 male, age 47 ± 12 years, 79% dilated cardiomyopathy, left ventricular ejection fraction 23 ± 10%] received continuous-flow LVAD as a bridge to transplantation over an 18 month period.
Objectives: The optimum time after brainstem death (BSD) at which to assess the function of donor hearts is unknown. We hypothesized that a longer interval may be associated with a higher transplantation rate due to improved function.
Methods: Data were obtained from the UK Transplant Registry for the period between April 2010 and March 2015.
Necrotizing eosinophilic myocarditis is a rare but potentially fatal condition that requires prompt recognition and treatment. We describe a case of a young athlete presenting with chest pain and breathlessness, with evidence of rapidly deteriorating cardiac function. The condition was successfully treated with corticosteroids, with no evidence of residual myocardial damage.
View Article and Find Full Text PDFAdvances in left ventricular assist device (LVAD) therapy have resulted in increasing numbers of adult LVAD recipients in the community. However, device failure, stroke, bleeding, LVAD thrombosis and systemic infection can be life-threatening emergencies. Currently, four LVAD systems are implanted in six UK transplant centres, each of which provides device-specific information to local emergency services.
View Article and Find Full Text PDFObjectives: Advanced chronic heart failure (ACHF) is progressive with poor prognosis and quality of life (QoL). Heart transplantation (HTx) is an effective treatment for ACHF, but is limited by scarcity of donor hearts. Left ventricular assist device (LVAD) support is a useful bridging therapy, and short- and medium-term outcomes have improved.
View Article and Find Full Text PDFThe aim of this study was to elucidate the dynamic characteristics of the Thoratec HeartMate II (HMII) and the HeartWare HVAD (HVAD) left ventricular assist devices (LVADs) under clinically representative in vitro operating conditions. The performance of the two LVADs were compared in a normothermic, human blood-filled mock circulation model under conditions of steady (nonpulsatile) flow and under simulated physiologic conditions. These experiments were repeated using 5% dextrose in order to determine its suitability as a blood analog.
View Article and Find Full Text PDFObjective: The outcomes of ventricular assist device therapy remain limited by right ventricular failure. We sought to define the predictors and evaluate the outcomes of right ventricular failure requiring right ventricular assist device support after long-term continuous-flow left ventricular assist device implantation.
Methods: Records of all continuous-flow left ventricular assist device recipients for the last 10 years were analyzed, including patients on preoperative intra-aortic balloon pump, extracorporeal membrane oxygenation, and short-term ventricular assist device support.
Giant cell myocarditis (GCM) is an aggressive inflammatory myocardial disease. Immunosuppression is an effective treatment for some cases. However, the duration of action of agents such as muromonab CD3 is short and others such as the calcineurin inhibitors may lead to renal failure.
View Article and Find Full Text PDFBackground: There are few data relating to sirolimus overdose in the medical literature. Our objectives were to describe all cases of overdose with sirolimus reported to Swiss, German and Austrian Poisons Centres between 2002-2013.
Methods: An observational case-series analysis was performed to determine circumstances, magnitude, management and outcome of sirolimus overdose.
Gene therapy has been applied to cardiovascular disease for over 20 years but it is the application to heart failure that has generated recent interest in clinical trials. There is laboratory and early clinical evidence that delivery of sarcoplasmic reticulum calcium ATPase 2a (SERCA2a) gene therapy is beneficial for heart failure and this therapy could become the first positive inotrope with anti-arrhythmic properties. In this review we will discuss the rationale for SERCA2a gene therapy as a viable strategy in heart failure, review the published data, and discuss the ongoing clinical trials, before concluding with comments on the future challenges and potential for this therapy.
View Article and Find Full Text PDFInteract Cardiovasc Thorac Surg
June 2015
Objectives: Traditionally, patients on extracorporeal life support (ECLS) are sedated and mechanically ventilated and therefore prone to complications related to immobility and ventilation. We adopted this 'Awake ECLS' strategy for the patients with refractory cardiogenic shock (RCS) as a bridge to decision.
Methods: Sixty-eight patients with RCS were supported by ECLS (All veno-arterial) in years 2010-2014.
Transplantation
September 2015
Background: Heart transplantation is an established treatment for advanced heart failure. Primary allograft dysfunction (PGD) is reported in up to 40% of transplants and is associated with a poor outcome.
Methods: As part of Heart Evaluation and Retrieval for Transplantation study, an investigation of the assessment of donor hearts for transplantation, we proposed a clinical definition for cardiac PGD comprising severely impaired systolic function affecting one or both ventricles accompanied by hypotension, low cardiac output, and high filling pressures occurring in the first 72 hours (in the absence of hyper acute rejection and technical surgical factors, such as cardiac tamponade).
The recent discovery of heterozygous human mutations that truncate full-length titin (TTN, an abundant structural, sensory, and signaling filament in muscle) as a common cause of end-stage dilated cardiomyopathy (DCM) promises new prospects for improving heart failure management. However, realization of this opportunity has been hindered by the burden of TTN-truncating variants (TTNtv) in the general population and uncertainty about their consequences in health or disease. To elucidate the effects of TTNtv, we coupled TTN gene sequencing with cardiac phenotyping in 5267 individuals across the spectrum of cardiac physiology and integrated these data with RNA and protein analyses of human heart tissues.
View Article and Find Full Text PDFBackground: A severe shortage of available donor organs has created an impetus to use extended criteria organs for heart transplantation. Although such attempts increase donor organ availability, they may result in an adverse donor-recipient risk profile. The TransMedics Organ Care System (OCS) (TransMedics, Inc, Boston) allows preservation of the donor heart by perfusing the organ at 34°C in a beating state, potentially reducing the detrimental effect of cold storage and providing additional assessment options.
View Article and Find Full Text PDFArtif Organs
March 2015
The purpose of this study was to evaluate gender differences regarding outcome after continuous-flow left ventricular assist device (cfLVAD) implantation. The study was a retrospective review of prospectively collected data. Included were 24 consecutive female cfLVAD recipients and 24 male recipients (62.
View Article and Find Full Text PDFInteract Cardiovasc Thorac Surg
November 2014
Objectives: The Synergy CircuLite micropump is a novel partial-support miniature left ventricular assist device that propels 2-3 l/min blood from the left atrium into the right subclavian artery. The ability of currently available investigative modalities to confirm Synergy pump malfunction is limited. The Synergy speed fluctuates periodically (at 10-s intervals) from the baseline to a transient decrease followed by a transient increase (alternating speed algorithm, ASA) with the purpose of changing the blood flow behaviour, thereby reducing thrombogenicity.
View Article and Find Full Text PDFBackground: Significant aortic regurgitation (AR) after continuous-flow left ventricular assist device (cf-LVAD) placement affects device performance and patient outcomes. This study examined the development of AR and long-term results after implantation of cf-LVADs.
Methods: The study included all patients with no or less than mild AR who underwent HeartMate II (58 [62%]; Thoratec Corp, Pleasanton, CA) or HeartWare (35 [38%]; HeartWare International, Framingham, MA) implantation at our institute from July 2006 to July 2012.
Ann Thorac Cardiovasc Surg
January 2016
Purpose: Despite their efficacy, LVADs remain associated with serious complications. The relationship between haemodynamic changes during support and outcome remains inadequately characterised. This association was investigated in LVAD recipients undergoing prolonged support.
View Article and Find Full Text PDFThe Synergy Micro-pump is the smallest implantable left ventricular assist device (LVAD) and provides partial flow support up to 4.25 L/min. It was shown that early intervention with this device can provide substantial benefits to patients with severe heart failure not yet sick enough for a full-support LVAD.
View Article and Find Full Text PDF