Mass spectrometry (MS) is a powerful analytical technique that typically involves sample preparation and online analytical separation before MS detection. Traditional methods often face bottlenecks in sample preparation and analytical separation, despite the rapid detection capabilities of MS. This review explores the integration of electrokinetic manipulations directly with the ionization step to enhance MS performance, focusing on methods that eliminate or simplify sample preparation and separation processes.
View Article and Find Full Text PDFWe developed a simple, paper-based device that enables sensitive detection by mass spectrometry (MS) without solid phase extraction or other sample preparation. Using glass fiber filter papers within a 3D printed holder, the device employs electrokinetic manipulations to stack, separate, and desalt charged molecules on paper prior to spray into the MS. Due to counter-balanced electroosmotic flow and electrophoresis, charged analytes stack on the paper and desalting occurs in minutes.
View Article and Find Full Text PDFDrug overdoses have risen dramatically in recent years. We developed a simple nontargeted method using a disposable paper spray cartridge with an integrated solid phase extraction column. This method was used to screen for ~160 fentanyl analogs, synthetic cannabinoids, other synthetic drugs, and traditional drugs of abuse in over 300 authentic overdose samples collected at emergency departments in Indianapolis.
View Article and Find Full Text PDFMicroneedles are widely used substrates for various chemical and biological sensing applications utilizing surface-enhanced Raman spectroscopy (SERS), which is indeed a highly sensitive and specific analytical approach. This article reports the fabrication of a nanoparticle (NP)-decorated microneedle substrate that is both a SERS substrate and a substrate-supported electrospray ionization (ssESI) mass spectrometry (MS) sample ionization platform. Polymeric ligand-functionalized gold nanorods (Au NRs) are adsorbed onto superhydrophobic surface-modified polydimethylsiloxane (PDMS) microneedles through the control of various interfacial interactions.
View Article and Find Full Text PDFThe rise of fentanyl and fentanyl analogs in the drug supply pose serious threats to public health. Much of these compounds enter the United States through shipping routes. Here we provide a method for fentanyl screening and analysis that utilizes pressure-sensitive adhesive (PSA) lined paper to recover drug residues from parcel-related surfaces.
View Article and Find Full Text PDFIllicit drug trafficking and abuse is a significant public safety and health concern. Color tests are commonly used for drug screening, but their poor specificity results in false positives. This study demonstrates the combination of drug residue collection using pressure-sensitive adhesive paper, on-paper color testing, and post-reaction analysis by paper spray mass spectrometry (PS-MS) on both portable and benchtop ion trap MS.
View Article and Find Full Text PDFPaper spray mass spectrometry (PS-MS) has been shown to be a rapid, simple and inexpensive alternative to traditional forensic drug screening methods. It can address the limitations of both immunoassays and chromatography-based techniques due to its non-reliance on sample preparation and its ability to rapidly screen for a wide array of compounds. In this study, an automated PS-MS system was employed to semi-quantitatively screen for 40 commonly abused drugs and metabolites in urine after a 15-min glucuronidase reaction.
View Article and Find Full Text PDFIntroduction: Remdesivir (GS-5734) is a nucleoside analog prodrug with antiviral activity against several single-stranded RNA viruses, including the novel severe respiratory distress syndrome virus 2 (SARS-CoV-2). It is currently the only FDA-approved antiviral agent for the treatment of individuals with COVID-19 caused by SARS-CoV-2. However, remdesivir pharmacokinetics/pharmacodynamics (PK/PD) and toxicity data in humans are extremely limited.
View Article and Find Full Text PDFIn this work, blow flies were investigated as environmental chemical sample collectors following a chemical warfare attack (CWA). Blow flies sample the environment as they search for water and food sources and can be trapped from kilometers away using baited traps. Three species of blow flies were exposed to CWA simulants to determine the persistence and detectability of these compounds under varying environmental conditions.
View Article and Find Full Text PDFIllicit drug use causes over half a million deaths worldwide every year. Drugs of abuse are commonly smuggled through customs and border checkpoints and, increasingly, through parcel delivery services. Improved methods for detection of trace drug residues from surfaces are needed.
View Article and Find Full Text PDFSurface-enhanced Raman scattering (SERS) is an ultrasensitive analytical technique, which is capable of providing high specificity; thus, it can be used for toxicological drug assay (detection and quantification). However, SERS-based drug analysis directly in human biofluids requires mitigation of fouling and nonspecificity effects that commonly appeared from unwanted adsorption of endogenous biomolecules present in biofluids (e.g.
View Article and Find Full Text PDFHerein we report the programmable preparation of ultrasensitive surface-enhanced Raman scattering (SERS)-based nanoplasmonic superlattice substrates to assay fentanyl and cocaine (detection and quantification) from 10 μL aliquots of emergency department patient plasma without the need for purification steps. Highly homogeneous three-dimensional (3D) nanoplasmonic superlattices are generated through the droplet evaporation-based self-assembly process of chemically-synthesized, polyethylene glycol thiolate-coated gold triangular nanoprisms (Au TNPs). Close-packed, solid-state 3D superlattice substrates produce electromagnetic hot spots due to near-field plasmonic coupling of Au TNPs, which display unique localized surface plasmonic resonance properties.
View Article and Find Full Text PDFRapid Commun Mass Spectrom
April 2020
Rationale: Paper spray mass spectrometry (PS-MS) was used to analyze and quantify ampicillin, a hydrophilic compound and frequently utilized antibiotic. Hydrophilic molecules are difficult to analyze via PS-MS due to their strong binding affinity to paper substrates and low ionization efficiency, among other reasons.
Methods: Solvent and paper parameters were optimized to increase the extraction of ampicillin from the paper substrate.
J Am Soc Mass Spectrom
March 2020
Cannabinoids present a unique set of analytical challenges. An increasing number of states have voted to decriminalize recreational marijuana use, creating a need for new kinds of rapid testing. At the same time, synthetic compounds with activity similar to THC, termed synthetic cannabinoids, have become more prevalent and pose significant health risks.
View Article and Find Full Text PDFBackground Invasive fungal disease is a life-threatening condition that can be challenging to treat due to pathogen resistance, drug toxicity, and therapeutic failure secondary to suboptimal drug concentrations. Frequent therapeutic drug monitoring (TDM) is required for some anti-fungal agents to overcome these issues. Unfortunately, TDM at the institutional level is difficult, and samples are often sent to a commercial reference laboratory for analysis.
View Article and Find Full Text PDFRapid vertebrate diversity evaluation is invaluable for monitoring changing ecosystems worldwide. Wild blow flies naturally recover DNA and chemical signatures from animal carcasses and feces. We demonstrate the power of blow flies as biodiversity monitors through sampling of flies in three environments with varying human influences: Indianapolis, IN and two national parks (the Great Smoky Mountains and Yellowstone).
View Article and Find Full Text PDFProteinaceous toxins are harmful proteins derived from plants, bacteria, and other natural sources. They pose a risk to human health due to infection and also as possible biological warfare agents. Paper spray mass spectrometry (PS-MS) with wipe sampling was used to detect proteins from surfaces as a potential tool for identifying the presence of these toxins.
View Article and Find Full Text PDFFilth flies are commonly implicated in pathogen transmission routes due to their affinity for vertebrate waste and their synanthropic associations. However, solidifying the link between flies and infected feces in the wild can be difficult, as interpretations made solely from microbial culturing or sequencing methods may represent an incomplete picture of pathogen acquisition. We present an analytical assay using high performance liquid chromatography tandem mass spectrometry (HPLC MS/MS) to detect vertebrate fecal metabolites (urobilinoids) in adult blow fly guts.
View Article and Find Full Text PDFImmunoassays and high-performance liquid chromatography (HPLC) coupled with mass spectrometry (MS) are both widely used methods for drug screening in toxicology. We investigated an alternative approach for rapid drug screening: paper spray MS (PS-MS). In paper spray, the biofluid sample is spotted onto a paper substrate.
View Article and Find Full Text PDFSample preparation is the most common bottleneck in the analysis and processing of forensic evidence. Time-consuming steps in many forensic tests involve complex separations, such as liquid and gas chromatography or various types of extraction techniques, typically coupled with mass spectrometry (e.g.
View Article and Find Full Text PDFPaper spray ionization mass spectrometry offers a rapid alternative platform requiring no sample preparation. Aerosolized chemical warfare agent (CWA) simulants trimethyl phosphate, dimethyl methylphosphonate, and diisopropyl methylphosphonate were captured by passing air through a glass fiber filter disk within a disposable paper spray cartridge. CWA simulants were aerosolized at varying concentrations using an in-house built aerosol chamber.
View Article and Find Full Text PDFWe developed a simple 3D printed cartridge for mass spectrometry (MS) targeted detection of plasma proteins, including post-translational modifications (PTMs). The cartridge uses an integrated antibody enrichment column to preconcentrate the protein target as well as a novel built-in substrate to ionize the protein targets for MS detection. We show several examples of using this cartridge to perform rapid detection of clinically significant proteoforms from plasma samples.
View Article and Find Full Text PDFPaper spray ionization coupled to a high resolution tandem mass spectrometer (a quadrupole orbitrap) was used to identify and quantitate chemical warfare agent (CWA) simulants and their hydrolysis products in blood and urine. Three CWA simulants, dimethyl methylphosphonate (DMMP), trimethyl phosphate (TMP), and diisopropyl methylphosphonate (DIMP), and their isotopically labeled standards were analyzed in human whole blood and urine. Calibration curves were generated and tested with continuing calibration verification standards.
View Article and Find Full Text PDFDrug monitoring of biofluids is often time consuming and prohibitively expensive. Analysis of dried blood spots offers advantages, such as reduced sample volume, but depends on extensive sample preparation and the presence of a trained lab technician. Paper spray mass spectrometry allows rapid analysis of small molecules from blood spots with minimal sample preparation, however, plasma is often the preferred matrix for bioanalysis.
View Article and Find Full Text PDF