α-Diketones such as diacetyl (2,3-butanedione) and 2,3-pentanedione are generated during the roasting and fermentation of foods and are also used as flavoring compounds. Exposure to these compounds has been associated with obliterative bronchiolitis in workers. We report indoor air concentrations of diacetyl and 2,3-pentanedione, as well as acetoin (3-hydroxy-2-butanone), in several small coffee roasteries and breweries using standard integrated air sampling sorbent tubes followed by gas chromatography tandem mass spectrometry as well as the first use of on-site continuous real-time proton-transfer reaction time-of-flight mass spectrometry (PTR-ToF-MS).
View Article and Find Full Text PDFRationale: The ability of membrane introduction mass spectrometry to quantitatively resolve low molecular weight volatile organic compounds (VOCs) such as benzene, toluene, ethylbenzene and xylene (BTEX) using electron ionization (EI) can be compromised by isobaric interferences. This work focuses on reducing isobaric interferences with ion-molecule reactions in a portable quadrupole ion trap mass spectrometer for the analysis of VOCs.
Methods: EI was used to produce reagent ions from precursors (chloroform, methyl iodide, trichloroethylene or chlorobenzene) that were continually infused into the helium acceptor phase upstream of the membrane introduction mass spectrometry (MIMS) sampling interface.
J Am Soc Mass Spectrom
February 2015
Development of small, field-portable mass spectrometers has enabled a rapid growth of in-field measurements on mobile platforms. In such in-field measurements, unexpected signal variability has been observed by the authors in portable ion traps with internal electron ionization. The orientation of magnetic fields (such as the Earth's) relative to the ionization electron beam trajectory can significantly alter the electron flux into a quadrupole ion trap, resulting in significant changes in the instrumental sensitivity.
View Article and Find Full Text PDFEnvironmental concentrations of volatile and semivolatile organic compounds (VOC/SVOCs) can vary dramatically in time and space under the influence of environmental conditions. In an industrial setting, multiple point and diffuse sources can contribute to fugitive emissions. Assessments and monitoring programs using periodic grab sampling provide limited information, often with delay times of days or weeks.
View Article and Find Full Text PDFJ Environ Sci Health A Tox Hazard Subst Environ Eng
September 2014
The objective of this study was to use membrane introduction mass spectrometry (MIMS), implemented on a mobile platform, in order to provide real-time, fine-scale, temporally and spatially resolved measurements of several hazardous air pollutants. This work is important because there is now substantial evidence that fine-scale spatial and temporal variations of air pollutant concentrations are important determinants of exposure to air pollution and adverse health outcomes. The study took place in Tacoma, WA during periods of impaired air quality in the winter and summer of 2008 and 2009.