Mixing at the microscale is of great importance for various applications ranging from biological and chemical synthesis to drug delivery. Among the numerous types of micromixers that have been developed, planar passive spiral micromixers have gained considerable interest due to their ease of fabrication and integration into complex miniaturized systems. However, less attention has been paid to non-planar spiral micromixers with various cross-sections and the effects of these cross-sections on the total performance of the micromixer.
View Article and Find Full Text PDFOne approach to achieve a homogeneous mixture in microfluidic systems in the quickest time and shortest possible length is to employ electroosmotic flow characteristics with heterogeneous surface properties. Mixing using electroosmotic flow inside microchannels with homogeneous walls is done primarily under the influence of molecular diffusion, which is not strong enough to mix the fluids thoroughly. However, surface chemistry technology can help create desired patterns on microchannel walls to generate significant rotational currents and improve mixing efficiency remarkably.
View Article and Find Full Text PDFDespite significant advances in left ventricular assist devices and the cannula, unfavorable events leading to the death of patients, including bleeding, infection, neurological disorders, hemolysis, and thrombosis, are still being reported. Local parameters of blood flow, including static flow, vorticity and critical values of shear stress on the wall of ventricle and cannula, increase the risk of thrombosis. Therefore, the analysis of blood flow domains inside the ventricle and cannula is necessary to investigate the probability of forming thrombosis in the cannula of left ventricular assist devices.
View Article and Find Full Text PDFMagnetic drug delivery known as smart technique in medicine is basically according to combining the drug inside capsules with the magnetic property or attaching the drug with magnetic surfaces at the micro- and nanoscale. In the present study, magnetic drug delivery in the aortic artery has been investigated. To approach the more realistic problem conditions of blood flow rheology, the effect of parameters such as non-Newtonian viscosity and oscillating input has been put into consideration.
View Article and Find Full Text PDFBiomech Model Mechanobiol
December 2020
Magnetic drug delivery as a potential method to treat diseases such as cancer tumors has attracted the attention of many researchers. One of the problems in conventional and ineffective therapies is the spread of drug in the circulatory system. The method of magnetic drug delivery aims at directing the drug to the localized area of disease by using a magnetic field.
View Article and Find Full Text PDFInertial microfluidics has emerged over the past decade as a powerful tool to accurately control cells and microparticles for diverse biological and medical applications. Many approaches have been proposed to date in order to increase the efficiency and accuracy of inertial microfluidic systems. However, the effects of channel cross-section and solution properties (Newtonian or non-Newtonian) have not been fully explored, primarily due to limitations in current microfabrication methods.
View Article and Find Full Text PDFSonication time has a significant contribution to the stability and properties of nanofluids (mixtures of nanoparticles and a base fluid). Finding the optimum sonication time can help to save energy and ensure optimal design. The present study deals with the sonication time effect on the evaporation rate of seawater containing a nanocomposite (i.
View Article and Find Full Text PDFElasto-inertial microfluidics has drawn significant attention in recent years due to its enhanced capabilities compared to pure inertial systems in control of small microparticles. Previous investigations have focused mainly on the applications of elasto-inertial sorting, rather than studying its fundamentals. This is because of the complexity of simulation and analysis, due to the presence of viscoelastic force.
View Article and Find Full Text PDFThe aim of this study is to introduce a general approach to implement curved boundaries in lattice Boltzmann simulations. The main idea is to determine boundary values by extrapolating macroscopic properties from some reference points inside the computational domain. The introduced approach is based on a unified extrapolation equation that can be employed for any macroscopic value (flow and nonflow properties) in arbitrary two- and three-dimensional geometries.
View Article and Find Full Text PDFIn this paper, an alternative approach to implement initial and boundary conditions in the lattice Boltzmann method is presented. The main idea is to approximate the nonequilibrium component of distribution functions as a third-order power series in the lattice velocities and formulate a procedure to determine boundary node distributions by using fluid variables, consistent with such an expansion. The velocity shift associated with the body force effects is included in this scheme, along with an approximation to determine the mass density in complex geometries.
View Article and Find Full Text PDFCarotid siphon is known as one of the risky sites among the human intracranial arteries, which is prone to formation of atherosclerotic lesions. Indeed, scientists believe that accumulation of low density lipoprotein (LDL) inside the lumen is the major cause of atherosclerosis. To this aim, three types of internal carotid artery (ICA) siphon have been constructed to examine variations of hemodynamic parameters in different regions of the arteries.
View Article and Find Full Text PDFLow-density lipoprotein (LDL), which is recognized as bad cholesterol, typically has been regarded as a main cause of atherosclerosis. LDL infiltration across arterial wall and subsequent formation of Ox-LDL could lead to atherogenesis. In the present study, combined effects of non-Newtonian fluid behavior and fluid-structure interaction (FSI) on LDL mass transfer inside an artery and through its multilayer arterial wall are examined numerically.
View Article and Find Full Text PDFThe interstitial fluid transport plays an important role in terms of its effect on the delivery of therapeutic agents to the cancerous organs. In this study, a comprehensive numerical simulation of the interstitial fluid transport establishing 3D models of tumor and normal tissue is accomplished. Different shapes of solid tumors and their surrounding normal tissues are selected, by employing the porous media model and incorporating Darcy's model and Starling's law.
View Article and Find Full Text PDFIntroduction: About 30 percent of the worldwide death is due to cardiovascular diseases. Clinical simulation is a promising filed that can help to understand diseases, their nature and intervention's effects. The simulated models are flexible and make it easy to study the changes' effects and help to select the appropriate interventions.
View Article and Find Full Text PDFPhys Rev E Stat Nonlin Soft Matter Phys
January 2014
Since the lattice Boltzmann method originally carries out the simulations on the regular Cartesian lattices, curved boundaries are often approximated as a series of stair steps. The most commonly employed technique for resolving curved-boundary problems is extrapolating or interpolating macroscopic properties of boundary nodes. Previous investigations have indicated that using more than one equation for extrapolation or interpolation in boundary conditions potentially causes abrupt changes in particle distributions.
View Article and Find Full Text PDFPhys Rev E Stat Nonlin Soft Matter Phys
May 2012
In this study the direct-simulation Monte Carlo (DSMC) method is utilized to investigate thermal characteristics of micro- or nanocavity flow. The rarefied cavity flow shows unconventional behaviors which cannot be predicted by the Fourier law, the constitutive relation for the continuum heat transfer. Our analysis in this study confirms some recent observations and shows that the gaseous flow near the top-left corner of the cavity is in a strong nonequilibrium state even within the early slip regime, Kn=0.
View Article and Find Full Text PDFAnn Biomed Eng
September 2010
The purpose of this study is to investigate the effects of the Reynolds number and the bend sweep angle on the blood flow patterns of S-shaped bends. The numerical simulations of steady flows in S-shaped bends with sweep angles of 45 degrees , 90 degrees , and 135 degrees are performed at Reynolds numbers of 125, 500, and 960. Hemodynamic characteristics such as secondary flows, vorticity, and axial velocity profiles are analyzed in detail.
View Article and Find Full Text PDF