Publications by authors named "Neus Godino"

Electroporation of cells is a widely-used tool to transport molecules such as proteins or nucleic acids into cells or to extract cellular material. However, bulk methods for electroporation do not offer the possibility to selectively porate subpopulations or single cells in heterogeneous cell samples. To achieve this, either presorting or complex single-cell technologies are required currently.

View Article and Find Full Text PDF

Continuous flow cell sorting based on image analysis is a powerful concept that exploits spatially-resolved features in cells, such as subcellular protein localisation or cell and organelle morphology, to isolate highly specialised cell types that were previously inaccessible to biomedical research, biotechnology, and medicine. Recently, sorting protocols have been proposed that achieve impressive throughput by combining ultra-high flow rates with sophisticated imaging and data processing protocols. However, moderate image quality and high complex experimental setups still prevent the full potential of image-activated cell sorting from being a general-purpose tool.

View Article and Find Full Text PDF

With the advent of single-cell technologies comes the necessity for efficient protocols to process single cells. We combine dielectrophoresis with open source computer vision programming to automatically control the trajectories of single cells inside a microfluidic device. Using real-time image analysis, individual cells are automatically selected, isolated and spatially arranged.

View Article and Find Full Text PDF

Cultivation of adherently growing cells in artificial environments is of utmost importance in medicine and biotechnology to accomplish in vitro drug screening or to investigate disease mechanisms. Precise cell manipulation, like localized control over adhesion, is required to expand cells, to establish cell models for novel therapies and to perform noninvasive cell experiments. To this end, we developed a method of gentle, local lift-off of mammalian cells using polymer surfaces, which are reversibly and repeatedly switchable between a cell-attractive and a cell-repellent state.

View Article and Find Full Text PDF

This work for the first time presents the full integration and automation concept for a range of bioassays leveraged by cascading a centrifugo-pneumatic valving scheme to sequentially move several liquids through shared channel segments for multi-step sample preparation into the detection zone. This novel centrifugo-pneumatic liquid handling significantly simplifies system manufacture by obviating the need for complex surface functionalization procedures or hybrid material integration, as it is common in conventional valving methods such as capillary burst valves or sacrificial valves. Based on the centrifugo-pneumatic valving scheme, this work presents a toolkit of operational elements implementing liquid loading/transfer, metering, mixing and sedimentation in a microstructured polymer disc.

View Article and Find Full Text PDF

This work demonstrates the design and fabrication of an all cyclo-olefin polymer based microfluidic device capable of capturing magnetic beads and performing electrochemical detection in a series of gold electrodes. The size of chip is of a microscope slide and features six independent measuring cells for multianalyte detection purposes. The aim of this work is to show that rapid prototyping techniques can be instrumental in the development of novel bioassays, particularly in clinical diagnosis applications.

View Article and Find Full Text PDF

We present a novel, low-resource fabrication and assembly method for creating disposable amperometric detectors in hybrid paper-polymer devices. Currently, mere paper-based microfluidics is far from being able to achieve the same level of process control and integration as state-of-the-art microfluidic devices made of polymers. To overcome this limitation, in this work both substrate types are synergistically combined through a hybrid, multi-component/multi-material system assembly.

View Article and Find Full Text PDF
Article Synopsis
  • This paper presents an innovative immunosensing system that detects bacteria using a combination of immunomagnetic capture and amperometric detection in a single step within a microfluidic setup.
  • The detection utilizes horseradish peroxidase (HRP) to catalyze hydrogen peroxide in the presence of hydroquinone, allowing for efficient enzyme monitoring in a controlled micro-chamber to minimize fouling of the electrodes.
  • The method, tested successfully on Escherichia coli, can detect bacteria concentrations as low as 55 cells/ml and operates effectively in various samples, including milk, without significant interference from other bacteria.
View Article and Find Full Text PDF

This work features the design, fabrication and characterisation of a miniaturised electroanalytical lab on a chip that allows the performance of a complete bioassay, from the capture of magnetic particles through their functionalisation and sample incubation to the detection of electroactive reaction products. The system is built using mainly polymeric materials such as PMMA and PDMS and fast prototyping techniques such as milling and moulding. The system also includes a set of microelectrodes, photo-lithographed on a silicon chip.

View Article and Find Full Text PDF

An external electric field driven in-channel detection technique for on-chip electrochemical detection in micro fabricated devices is described based on a microfluidic system containing an array of 20 microband electrodes. It is shown that an external electric field induces a potential difference between two gold microband electrodes in a poly(dimethylsiloxane) (PDMS) microchannel, and that this enables the electrochemical detection of electroactive species such as ascorbic acid and Fe(CN) 6 (4-). The results, which are supported by simulations of the behavior of the microband electrodes in the microfluidic system, show that the induced potential difference between the electrodes can be controlled by altering the external electric field or by using different microbands in the microband array.

View Article and Find Full Text PDF