Statement Of The Problem: Poly-etheretherketone is a novel material used in the construction of the removable partial dentures frameworks instead of the metal frameworks. This material can be fabricated by various techniques. Most common methods are the injection molding or Computer Aided Design/Computer Aiding Manufacturing (CAD/CAM) milling techniques.

View Article and Find Full Text PDF

Objectives: To evaluate the impact of implants number and attachments type on the peri-implant stresses and retention of maxillary palateless implant-supported overdenture.

Materials And Methods: Four edentulous maxillary educational acrylic resin models were used. According to the implants number and type of attachment used, four groups were compared: Group I, 2-locator attachments in the canine area; Group II, 2- OT equator attachments in the canine area; Group III, 4-locator attachments in the canine, second premolar area and Group IV, 4-OT equator attachments in the canine, second premolar area.

View Article and Find Full Text PDF

Background: This study was aimed to evaluate the influence of inter-implant distance on the wear characteristics of low-profile stud attachments used in mandibular implant retained overdentures.

Material And Methods: Forty Completely edentulous participants aged between 50 - 70 years were enrolled in this study. Each patient received 2-implants by 2-stage submerged surgical protocol.

View Article and Find Full Text PDF

The aim of this in vitro study was to evaluate the effect of implant position and edentulous span length on stresses around implants assisting claspless distal extension partial overdentures. Four bilateral mandibular distal extension acrylic models were constructed. Two implants were inserted in the distal extension ridges parallel to each other and perpendicular to the ridges.

View Article and Find Full Text PDF

Purpose: The objective of this study was radiographic assessment of the premolar teeth abutments alveolar bone resorption in mandibular Kennedy Class I removable partial denture (RPD) utilizing the broad stress distribution philosophy, either designed with multiple circlet clasp or compound Aker clasp.

Materials And Methods: Twelve patients were enrolled for this study with upper completely edentulous arch against mandibular Kennedy Class I ridges posterior to the second premolar. The patients were divided into two groups according to the type of the clasp assembly design used, where the mandibular Kennedy Class I RPD was designed with multiple circlet clasp and compound Aker clasp assemblies for Groups I and II, respectively.

View Article and Find Full Text PDF

Aim: : Investigating possible failure causes of mandibular implants after their immediate loading with an overdenture retained with bilateral bar attachments, using scanning electron microscope.

Patients And Methods: Twenty edentulous male patients were included in the present study. Each patient had 2 fixtures inserted in the canine and the first molar areas on each side of the mandible.

View Article and Find Full Text PDF