Publications by authors named "Nergueze Aydin Cakir"

: This study aimed to evaluate the long-term adverse effects on the physical appearance and overall well-being of breast cancer patients who receive hypofractionated radiotherapy as whole breast and simultaneous integrated boost (SIB) treatment, utilizing intensive modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT), or a hybrid therapy approach. : This investigation involved administering hypofractionated SIB-VMAT therapy to individuals diagnosed with early-stage breast cancer. Treatment was carried out over a three-week period in which a total dose of 48.

View Article and Find Full Text PDF

As the Stereotactic Body Radiotherapy (SBRT) approach began to increase in treating patients with localized prostate cancer, it became necessary to investigate which methods used in practice were better. The aim of this study is to perform a dosimetric comparison of the advantages and disadvantages of SBRT treatments for localized prostate cancer delivered by CyberKnife (CK) and Varian Truebeam STX (FF and FFF). Seventeen intermediate and high-risk patients with localized prostate cancer were included in the study.

View Article and Find Full Text PDF

Purpose: This study aims to investigate the factors that reduce fetal dose in pregnant patients with breast cancer throughout their radiation treatment. Two main factors in a standard radiation oncology center are considered as the treatment planning systems (TPSs) and simple shielding for intensity modulated radiation therapy technique.

Materials And Methods: TPS factor was evaluated with two different planning algorithms: Anisotropic analytical algorithm and Acuros XB (external beam).

View Article and Find Full Text PDF

Radiotherapy has an important role in the treatment of prostate cancer. Three-dimensional conformal radiation therapy (3D-CRT), intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) techniques are all applied for this purpose. However, the risk of secondary radiation-induced bladder cancer is significantly elevated in irradiated patients compared surgery-only or watchful waiting groups.

View Article and Find Full Text PDF

In recent years, small-field electron beams have been used for the treatment of superficial lesions, which requires small circular fields. However, when using very small electron fields, some significant dosimetric problems may occur. In this study, dose distributions and outputs of circular fields with dimensions of 5cm and smaller, for nominal energies of 6, 9, and 15MeV from the Siemens ONCOR Linac, were measured and compared with data from a treatment planning system using the pencil-beam algorithm in electron beam calculations.

View Article and Find Full Text PDF

Introduction And Objectives: Nosocomial infections, also known as hospital-acquired infections, has become one of the most important health problems in health care units worldwide. The presented study aims to determine the average amount of microorganism loads and to show that the atmospheres of the two hospitals can be a potential source regarding nosocomial infections. The effect of surface and floor disinfection processes in the two hospitals and the antibiotic susceptibility of the bacterial isolates were also evaluated.

View Article and Find Full Text PDF

Purpose: High-energy photons are most commonly used in radiotherapy to treat cancer. Wedge filters are required to obtain homogeneous dose distribution in the patient. Different wedge filter types create different surface doses.

View Article and Find Full Text PDF

The aim of this study is to determine the effect of bolus to the surface dose in oblique electron incidences. Irradiations with 4.5, 6, 7.

View Article and Find Full Text PDF

The aim of this study was to determine the surface doses using GafChromic EBT films and compare them with plane-parallel ionization chamber measurements for 6 and 18 MV high energy photon beams. The measurements were made in a water equivalent solid phantom in the build-up region of the 6 and 18MV photon beams at 100 cm SSD for various field sizes. Markus type plane-parallel ion chamber with fixed-separation between collecting electrodes was used to measure the percent depth doses.

View Article and Find Full Text PDF