Publications by authors named "Nele Stoppie"

The aim of this study was to examine the influence of the Young's modulus of the implant material on the bone remodeling in a loaded condition. A combined animal experimental and computational study was set up. The animal experimental group comprised of 16 Saanen goats, each receiving one titanium implant (Young's modulus 110 GPa) and one high-density polyethylene (HDPE) implant (Young's modulus 1 GPa) in the left femoral condyle.

View Article and Find Full Text PDF

Objectives: The goal of this study was to examine the feasibility of in vivo imaging of trabecular bone around titanium implants by means of microfocus computed tomography (micro-CT) and the use of rabbits for this purpose.

Materials And Methods: Ten male rabbits type Hollander, received a titanium implant (1.7 mm diameter and 10 mm length) in the trabecular bone of the left tibia.

View Article and Find Full Text PDF

Purpose: The aim of this study was to determine a reliable compression testing method for cancellous jawbone specimens and to validate it by high-resolution finite element (FE) modeling based on microcomputerized tomography (microCT) images of the specimens.

Materials And Methods: Three series of human femoral bone samples were tested to establish a compression protocol for human jawbone cores. A microCT scan of each bone sample was obtained.

View Article and Find Full Text PDF

Objectives: The aim of this study was to determine the Hounsfield values of selected bone sites on a computed tomography (CT) scan of the jaw and to investigate the relationship between this radiological parameter and structural parameters.

Materials And Methods: A selection of 24 bone samples out of eight cadaver human jaws was made. The following parameters were measured: Hounsfield value in the jaw (HU1) determined by a first CT scan, Hounsfield value of the excised bone specimen (HU2) by a second CT scan, bone mineral density (BMD) by a dual-energy X-ray absorptiometry scan, bone volume (BV/TV) by the microfocus CT scan, first peak transmission time (T(US-1)) and first zero crossing transmission time (T(US-2)) by an ultrasound measurement and Young's modulus (E(MECH)) by a compression test.

View Article and Find Full Text PDF

Background: Microfocus computed tomography (muCT) is an emerging technique owing to its speed, full three-dimensional information, and nondestructive properties.

Purpose: The aim of this study was to explore the efficacy of a muCT system (Philips HOMX 161, Philips Medical Systems GmbH, Hamburg, Germany) for visualization of the bone structure around screw-type titanium implants by comparing muCT images with their histologic homologues.

Materials And Methods: Eight screw-type titanium implants were placed in the femoral condyles of two goats.

View Article and Find Full Text PDF