Med Devices (Auckl)
November 2016
Poor patient compliance or nonadherence with prescribed treatments can have a significant unfavorable impact on medical costs and clinical outcomes. In the current study, voice-of-the-customer research was conducted to aid in the development of a next-generation low-intensity pulsed ultrasound (LIPUS) bone healing product. An opportunity to improve patient compliance reporting was identified, resulting in the incorporation into the next-generation device of a visual calendar that provides direct feedback to the patient, indicating days for which they successfully completed treatment.
View Article and Find Full Text PDFIt has been 30years since the first level one clinical trial demonstrated low intensity pulsed ultrasound (LIPUS) could accelerate fracture repair. Since 1994 numerous investigations have been performed on the effect of LIPUS. The majority of these studies have used the same signal parameters comprised of an intensity of 30mW/cm(2) SATA, an ultrasound carrier frequency of 1.
View Article and Find Full Text PDFLow intensity pulsed ultrasound (LIPUS) was reported to accelerate the rate of fracture healing. When LIPUS is applied to fractures transcutaneously, bone tissues at different depths are exposed to different ultrasound fields. Measurement of LIPUS shows pressure variations in near field (nearby transducer); uniform profile was found beyond it (far field).
View Article and Find Full Text PDFThis study investigated the effect of LIPUS on fracture healing when fractures were exposed to ultrasound at three axial distances: z=0 mm, 60 mm, and 130 mm. We applied LIPUS to rat fracture at these three axial distances mimicking the exposure condition of human fractures at different depths under the soft tissue. Measurement of LIPUS shows pressure variations in near field (nearby transducer); uniform profile was found beyond it (far field).
View Article and Find Full Text PDFLow-intensity pulsed ultrasound (LIPUS) with I(SATA)= 30 mW/cm(2) has been proven in facilitating fracture healing, which the spatial average intensity over the on period (I(SATP)) equals 150 mW/cm(2). As active ultrasound wave is only delivered during the on period, we postulate 150 mW/cm(2) is responsible for the beneficial effect of LIPUS. In this study, we compare the biologic effects of 30 mW/cm(2) and 150 mW/cm(2).
View Article and Find Full Text PDFLow-intensity pulsed ultrasound (LIPUS) was shown to have dose-dependent enhancement effect on the osteogenic activity of human periosteal cells that played an important role in fracture healing. It was hypothesized that the stimulatory effects of LIPUS on the periosteal cells could be optimized by adjusting the ultrasound delivered at its critical angle to the surface of bone. This increased the transmission of ultrasound waves on periosteum.
View Article and Find Full Text PDFIn the United States, over 17 million people are diagnosed with type 1 diabetes mellitus (DM) with its inherent morbidity of delayed bone healing and nonunion. Recent studies demonstrate the utility of pulsed low-intensity ultrasound (LIPUS) to facilitate fracture healing. The current study evaluated the effects of daily application of LIPUS on mid-diaphyseal femoral fracture growth factor expression, cartilage formation, and neovascularization in DM and non-DM BB Wistar rats.
View Article and Find Full Text PDFLow intensity pulsed ultrasound is used in the clinical treatment of fractures and other osseous defects. Level I clinical studies demonstrate the ability of a specific ultrasound signal (1.5 MHz ultrasound pulsed at 1 kHz, 20% duty cycle, 30 mW/cm(2) intensity (SATA)) to accelerate the healing time in fresh tibia, radius and scaphoid fractures by up to 40%.
View Article and Find Full Text PDFJ Biomed Mater Res B Appl Biomater
July 2008
A 1.5 cm unilateral rabbit ulna defect model was performed in 18 adult NZ white rabbits. The defects were filled with a beta-tricalcium phosphate bone graft substitute (JAX TCP).
View Article and Find Full Text PDF