Gadolinium-based contrast agents (GBCAs) have augmented the capabilities of MRI, which has led to their widespread and increasing use in radiology practice. GBCAs are introduced into the environment through disposal of unused product and elimination after intravenous injection, both primarily via liquid dispersion into the environment. This human introduction of gadolinium into the environment, referred to as anthropogenic gadolinium, is associated with the detection of gadolinium in water systems, raising concerns for potential adverse impact and prompting certain mitigation actions.
View Article and Find Full Text PDFMultiparametric MRI-the most accurate imaging technique for detection of prostate cancer-has transformed the landscape of prostate cancer diagnosis by enabling targeted biopsies. In a targeted biopsy, tissue samples are obtained from suspicious regions identified at prebiopsy diagnostic MRI. The authors briefly compare the different strategies available for targeting an MRI-visible suspicious lesion, followed by a step-by-step description of the direct MRI-guided in-bore approach and an illustrated review of its application in challenging clinical scenarios.
View Article and Find Full Text PDFBackground: The prostatic apex is the most frequent location of positive surgical margin (PSM) after surgery. Data regarding the ability of multiparametric magnetic resonance imaging (mpMRI) to prospectively identify men at risk for apical PSMs (aPSMs) using a structured report are lacking.
Objectives: The aims of the study are to determine and to compare the rate of aPSM in men with versus without prospectively flagged at-risk prostate lesions during clinical mpMRI interpretation using whole-mount histopathology as the reference standard.
The impact of supply chain and supply chain logistics, including personnel directly and indirectly related to the movement of supplies, has come to light in a variety of industries since the global COVID-19 pandemic. Acutely, the experience with baby formula and iodinated contrast material exposes key vulnerabilities to supply chains. The rather sudden diminished availability of iodinated contrast material has forced health care systems to engage in more judicious use of product through catalyzing the adoption of behaviors that had been recommended and deemed reasonable prior to the shortage.
View Article and Find Full Text PDFInvest Radiol
July 2021
Objectives: In the United States, prostate cancer (PCa) is the most common cancer in men. Multi-parametric magnetic resonance imaging (MRI) is increasingly being relied upon for the diagnosis and characterization of PCa, but differentiating malignancy from benign prostatic hyperplasia (BPH) in the transition zone using MRI can be challenging. The characteristically high levels of zinc in human prostate tissue and a close relationship between malignant proliferation and zinc homeostatic dysregulation create opportunities to visualize PCa with novel contrast media.
View Article and Find Full Text PDFPurpose: To develop a true single shot turbo spin echo (SShTSE) acquisition with Dixon for robust T -weighted abdominal imaging with uniform fat and water separation at 3T.
Methods: The in-phase (IP) and out-of-phase (OP) echoes for Dixon processing were acquired in the same repetition time of a SShTSE using partial echoes. A phase-preserved bi-directional homodyne reconstruction was developed to compensate the partial echo and the partial phase encoding of SShTSE.
Purpose: To determine and compare rates of grade group (GG) discrepancies between different targeted biopsy techniques (in-bore vs fusion) after propensity score weighting using whole-mount radical prostatectomy (RP) histopathologic analysis as the reference standard.
Materials And Methods: This retrospective study evaluated men who underwent targeted (fusion or in-bore) biopsy between April 2017 and January 2019 followed by prostatectomy. The primary endpoint of the study was a change in GG from biopsy to RP at a patient level.
Objective: To determine the incremental detection rate of clinically significant prostate cancer (csPCa) provided by sequential cores during in-bore magnetic resonance imaging (MRI)-guided prostate biopsies.
Methods: Single-center, retrospective interpretation of prospectively acquired data in men without previous diagnosis of csPCa who underwent in-bore MRI-guided prostate biopsy between May 2017 and December 2019. Endpoints included detection of csPCa (grade group [GG] ≥ 2) and rate of GG upgrade provided by additional cores.
A dearth of women leaders in the field of radiology and affiliated industries persists despite a recognition of the importance, value, and impact that would derive from its rectification. A targeted educational collaboration, described herein, was established between academia and industry to address this deficit and to facilitate the placement of highly qualified women into leadership positions. The actionable platform offered has the potential to narrow the gap for underrepresented groups in professional leadership positions.
View Article and Find Full Text PDFOn the basis of expert consensus, PI-RADS version 2.1 (v2.1) introduced the transition zone (TZ) atypical benign prostatic hyperplasia (BPH) nodule, defined as a TZ lesion with an incomplete or absent capsule (T2 score, 2).
View Article and Find Full Text PDFThe coronavirus disease 2019 (COVID-19) pandemic has necessitated rapid response plans to minimize risks of infection in the workforce while ensuring maintenance of essential functions of radiology departments. Plan adoption is, however, challenged by the need to coordinate with institutional efforts, a rapidly expanding number of patients, and the diversity of clinical and administrative functions in the department. Here, we describe the implementation of a response plan in an academic radiology department, challenges encountered, and tactics used to address these challenges.
View Article and Find Full Text PDFBackground: For most computer-aided diagnosis (CAD) problems involving prostate cancer detection via medical imaging data, the choice of classifier has been largely ad hoc, or been motivated by classifier comparison studies that have involved large synthetic datasets. More significantly, it is currently unknown how classifier choices and trends generalize across multiple institutions, due to heterogeneous acquisition and intensity characteristics (especially when considering MR imaging data). In this work, we empirically evaluate and compare a number of different classifiers and classifier ensembles in a multi-site setting, for voxel-wise detection of prostate cancer (PCa) using radiomic texture features derived from high-resolution in vivo T2-weighted (T2w) MRI.
View Article and Find Full Text PDFObjective: The purpose of this study is to determine the reproducibility and diagnostic performance of a Likert scale in comparison with the European Society of Urogenital Radiology (ESUR) criteria and tumor-pseudocapsule contact length (TCL) for the detection of extraprostatic extension (EPE) at multiparametric MRI.
Materials And Methods: This was a retrospective review of all men who underwent multiparametric MRI followed by prostatectomy between November 2015 and July 2016. Multiparametric 3-T MRI studies with an endorectal coil were independently reviewed by five readers who assigned the likelihood of EPE using a 1-5 Likert score, ESUR criteria, and TCL (> 10 mm).
Purpose: To develop a whole-body MRI technique at 3T with improved lesion conspicuity for metastatic cancer detection using fast, high-resolution and high SNR T -weighted (T W) imaging with simultaneous fat and fluid suppression.
Theory And Methods: The proposed dual-echo T -weighted acquisition for enhanced conspicuity of tumors (DETECT) acquires 4 images, in-phase (IP) and out-of-phase (OP) at a short and a long TE using single-shot turbo spin echo. The IP/OP images at the short and long TEs are reconstructed using the standard Dixon and shared-field-map Dixon reconstruction respectively, for robust fat-water separation.
Objectives: The aim of this study was to compare the anatomical registration of preoperative magnetic resonance imaging (MRI) and prostate whole-mount obtained with 3D-printed, patient-specific, MRI-derived molds (PSM) versus conventional whole-mount sectioning (WMS).
Materials And Methods: Based on an a priori power analysis, this institutional review board-approved study prospectively included 50 consecutive men who underwent 3 T multiparametric prostate MRI followed by radical prostatectomy. Two blinded and independent readers (R1 and R2) outlined the contours of the prostate, tumor, peripheral, and transition zones in the MRI scans using regions of interest.
Background: Targeted prostate biopsies are changing the landscape of prostate cancer (PCa) diagnosis with the degree of suspicion on multiparametric magnetic resonance imaging (mpMRI) being a strong predictor of targeted biopsy outcome. Data regarding the rate and potential causes of false-negative magnetic resonance imaging-transrectal ultrasound (MRI-TRUS) fusion-targeted biopsy in patients with highly suspicious mpMRI findings are lacking.
Objectives: To determine the rate of clinically significant PCa detection in repeat targeted biopsy or surgery in patients with highly suspicious mpMRI findings and in an initial negative MRI-TRUS fusion-targeted biopsy.
This is the first of a series of 4 white papers that represent Expert Consensus Documents developed by the Society of Computed Body Tomography and Magnetic Resonance through its task force on dual-energy computed tomography (DECT). This article, part 1, describes the fundamentals of the physical basis for DECT and the technology of DECT and proposes uniform nomenclature to account for differences in proprietary terms among manufacturers.
View Article and Find Full Text PDFThis is the fourth of a series of 4 white papers that represent expert consensus documents developed by the Society of Computed Body Tomography and Magnetic Resonance through its task force on dual-energy computed tomography. This article, part 4, discusses DECT for abdominal and pelvic applications and, at the end of each, will offer our consensus opinions on the current clinical utility of the application and opportunities for further research.
View Article and Find Full Text PDFMany secretory tissues release Zn(II) ions along with other molecules in response to external stimuli. Here we demonstrate that secretion of Zn(II) ions from normal, healthy prostate tissue is stimulated by glucose in fasted mice and that release of Zn(II) can be monitored by MRI. An ∼50% increase in water proton signal enhancement is observed in T1-weighted images of the healthy mouse prostate after infusion of a Gd-based Zn(II) sensor and an i.
View Article and Find Full Text PDFPurpose: To compare a simplified intravoxel incoherent motion (sIVIM) model to commonly used monoexponential and biexponential models in the characterization of prostate cancer (PCa) and noncancerous prostate tissues, and to investigate combinations of diffusion-weighted imaging (DWI) measures with dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI)-derived parameters in MRI-visible index lesions, to facilitate PCa risk stratification.
Materials And Methods: In this retrospective, Institutional Review Board (IRB)-approved study, 43 consecutive patients with PCa who had 3T MRI exams followed by radical prostatectomy were included. DWI and DCE parameters were measured from one index lesion per patient, and noncancerous central gland and peripheral zone.
Urol Oncol
September 2016
Objective: To determine the incremental diagnostic value of targeted biopsies added to an extended sextant biopsy scheme on a per-patient, risk-stratified basis in 2 academic centers using different multiparametric magnetic resonance imaging (MRI) protocols, a large group of radiologists, multiple biopsy systems, and different biopsy operators.
Materials And Methods: All patients with suspected prostate cancer (PCa) who underwent multiparametric MRI of the prostate in 2 academic centers between February 2013 and January 2015 followed by systematic and targeted MRI-transrectal ultrasound fusion biopsy were reviewed. Risk-stratified detection rate using systematic biopsies was compared with targeted biopsies on a per-patient basis.
Objectives: To compare the sensitivity of 2 different non-endorectal coil strategies vs. endorectal coil (ERC) magnetic resonance imaging (MRI) for detection of prostate cancer (PCa).
Methods: In this prospective, single-center, paired-patient, paired-reader study, 49 men with a clinical indication for MRI underwent non-ERC (phased-array coil only) T2-weighted imaging and diffusion-weighted imaging followed by the same sequences using both ERC and phased-array coils (ERC Protocol).