Unlabelled: Accurate quantification of indoxyl sulfate (IndS) and -cresyl sulfate (pCS) is essential for understanding their role in chronic kidney disease (CKD) progression and for developing strategies to mitigate their harmful effects, including cardiovascular morbidity and renal fibrosis. Advances in liquid chromatography-high-resolution mass spectrometry (LC-HRMS) enable the integration of powerful diagnostic tools into clinical laboratories. Along with accurate quantification, precise mass measurements allow for untargeted compound identification.
View Article and Find Full Text PDFThe dialysis membrane based on a hydrophilic polymer (Hydrolink NV) was designed to enhance the movement of adsorbed water at the blood-membrane interface, aiming to achieve antithrombogenic and antifouling effects. This study aimed to assess the performance and albumin loss of the Hydrolink NV dialyzer in hemodialysis (HD) and post-dilution hemodiafiltration (HDF) with different infusion flows (Qis) and compare it with the hydrophilic FX CorAL dialyzer in post-dilution HDF. A prospective study was carried out in 20 patients.
View Article and Find Full Text PDF: High-volume online hemodiafiltration (OL-HDF) has proven to be the most efficient dialysis modality and to offer better clinical outcomes in patients on hemodialysis. Longer and more frequent dialysis sessions have demonstrated clinical and survival benefits. : A single-center observational study of the first one hundred patients on nocturnal every-other-day OL-HDF was conducted with the aim of reporting the experience with this treatment schedule and evaluating analytical and clinical outcomes as well as the patient and technique survival.
View Article and Find Full Text PDFPain is a frequent and disturbing symptom among hemodialysis patients. Protein-bound uremic toxins (PBUTs) are related to cardiovascular and overall mortality, and they are difficult to remove with current hemodialysis treatments. The PBUT displacers, such as furosemide, tryptophan, or ibuprofen, may be promising new strategies for improving their clearance.
View Article and Find Full Text PDFIntroduction: New generation helixone dialyzers has recently been developed as part of the ongoing effort to improve dialyzer hemocompatibility and avoid adverse reactions to synthetic dialyzers. This study aimed to assess the performance and albumin loss of this new dialyzer series in hemodiafiltration and compare it with the previous generation helixone series.
Material And Methods: A prospective study was conducted in 19 patients.
Background: New versions of the polyester polymer alloy (PEPA) membrane have appeared over the years, with increases in both the pore size and the amount of polyvinylpyrrolidone (PVP) to optimize hydrophilicity performance. This study aimed to assess the efficacy of the most recently developed PEPA dialyzer, the FDY series, in hemodialysis (HD) modality in terms of uremic toxin removal and albumin loss and to compare it with that of several high-flux dialyzers currently used in HD and post-dilution hemodiafiltration (HDF) treatments.
Methods: A prospective study was carried out in 21 patients.
Background: Recently, several pharmaceutical companies have developed new medium cut-off (MCO) dialyzers for expanded hemodialysis (HDx). This study aimed to compare the safety and efficacy of four MCO dialyzers, against each other and versus high-flux hemodialysis (HD) and post-dilution hemodiafiltration (HDF).
Methods: A prospective study was carried out on 23 patients who underwent six dialysis sessions: two sessions with the FX80 Cordiax in HD and HDF, and four HDx sessions with the Phylther 17-SD, Vie-18X, Elisio HX19 and Theranova 400 dialyzers.
Introduction: The Fourth Universal Definition of Myocardial Infarction Global Taskforce recommends the use of high sensitive troponin (hs-Tn) assays in the diagnosis of acute myocardial infarction. We evaluated the analytical performance of the Atellica IM High-sensitivity Troponin I Assay (hs-TnI) (Siemens Healthcare Diagnostics Inc., Tarrytown, USA) and compared its performance to other hs-TnI assays (Siemens Advia Centaur, Dimension Vista, Dimension EXL, and Abbott Architect (Wiesbaden, Germany)) at one or more sites across Europe.
View Article and Find Full Text PDFIntroduction: The medium cut-off Elisio HX dialyzer by Nipro became commercially available in Europe in 2021, but there are still no reports of in vivo data. This study aimed to evaluate the safety and efficacy of it compared with previously evaluated hemodialysis (HD), expanded HD (HDx), and postdilution hemodiafiltration (HDF) treatments.
Methods: A prospective study was carried out on 18 patients who underwent 5 dialysis sessions: FX80 Cordiax in HD, Elisio H19 in HD, Elisio HX19 in HDx, Theranova 400 in HDx, and FX80 Cordiax in HDF.
The Clearum dialyzer, built by Medtronic, became commercially available in several European countries in 2020, but there are still no reports of in vivo data. The aim of this study was to evaluate the efficacy and risk of hypoalbuminemia of this dialyzer compared with previously evaluated hemodialysis (HD), expanded hemodialysis (HDx), and postdilution hemodiafiltration (HDF) treatments. A prospective study was carried out in 15 patients.
View Article and Find Full Text PDFToray has created a new generation of dialyzers, the polysulphone (TS) UL series, and polymethylmethacrylate (PMMA) NF-U series, which offer enhanced efficacy over the previous TS-S series and NF-H series. The aim of this study was to evaluate the safety and efficacy of these dialyzer series versus contrasted expanded hemodialysis (HDx) and postdilution hemodiafiltration (HDF). We conducted a prospective study in 12 patients.
View Article and Find Full Text PDFBackground: Human breast milk (BM) fortification is required to feed preterm newborns with less than 32 weeks of gestation. However, addition of fortifiers increases osmolarity and osmolarity values higher than 450 mOsm/kg may be related to gastrointestinal pathology. Hence, fortifier selection and dosage are key to achieve optimal feeding.
View Article and Find Full Text PDFIntroduction: Laboratories minimize risks through quality control but analytical errors still occur. Risk management can improve the quality of processes and increase patient safety. This study aims to use the failure mode and effect analysis (FMEA) to assess the analytical performance and measure the effectiveness of the risk mitigation actions implemented.
View Article and Find Full Text PDFThe aim of the study was to compare expanded hemodialysis (HDx) with hemodiafiltration (HDF) at different infusion flows to identify the main determinants, namely blood flow (Qb), replacement volume, infusion flow (Qi), ultrafiltration flow (Q ), filtration fraction (FF), and the point at which the effectiveness of HDF equals or exceeds that of HDx. We conducted a prospective, single-center study in 12 patients. Each patient underwent 12 dialysis sessions: six sessions with Qb 350 and six with Qb 400 mL/min; with each Qb, one session was with HDx and five sessions were with FX80 (one in HD, and four with Qi 50, 75, 90/100 mL/min or autosubstitution in postdilution HDF).
View Article and Find Full Text PDFBackground The Atellica Solution comprises chemistry (CH) and immunoassay (IM) analyzers. Recently, six early adopter clinical laboratories across Europe evaluated the analytical performance of 20 CH and IM assays. To measure analytical performance quality, Sigma metrics were calculated for individual-site and pooled-site results.
View Article and Find Full Text PDFBlood flow (Qb) is one of the dialysis parameters most strongly influencing the performance of dialysis modalities. However, few studies have compared different dialysis modalities in patients with low Qb. We conducted a prospective, single-center study in 21 patients.
View Article and Find Full Text PDFIntroduction: Recently, a new class of dialyzers, medium cut-off membranes (MCO), designed to improve the permeability, which could provide an efficacy similar to hemodiafiltration, have been incorporated into our therapeutic possibilities. To increase the knowledge about its use, the objective of the study was to evaluate the effect of the surface and blood flow (Qb) on the depurative efficacy in the MCO membranes.
Material And Methods: We included 19 patients in the hemodialysis.
Most high-flux dialyzers can be used in both hemodialysis (HD) and online hemodiafiltration (OL-HDF). However, some of these dialyzers have higher permeability and should not be prescribed for OL-HDF to avoid high albumin losses. The aim of this study was to compare the safety and efficacy of a currently used dialyzer in HD and OL-HDF with those of several other high permeability dialyzers which should only be used in HD.
View Article and Find Full Text PDFNefrologia (Engl Ed)
October 2018
Introduction: Online haemodiafiltration (OL-HDF) has been associated with increased survival. To date, the influence of the inner diameter of the hollow fibres of the dialyser on convective volume has not been well established. The objective of the study was to evaluate the effect of increasing the inner diameter of the dialyser on the convective volume and removal capacity.
View Article and Find Full Text PDFBackground: Efforts aimed at reducing alcohol-related harm include early detection of risky drinkers as well as detection of early relapse in patients with alcohol dependence. Ethyl glucuronide (EtG) has been proven to be a reliable biomarker for the detection of recent drinking; however, no randomized, diagnostic trial to date has tested its impact on drinking outcomes. The aim of this study was to assess, in a randomized design, the implications of EtG screening on alcohol outcomes, compared to screening with a low sensitivity biomarker such as ethanol.
View Article and Find Full Text PDFBackground: Online haemodiafiltration (OL-HDF) is currently the most effective dialysis technique that also improves survival. To date, high permeability membranes with low albumin loss, such as polysulfone, polyamide and polyacrylonitrile membranes have been the most widely used. However, the initially restricted use of cellulose triacetate (CTA) membranes in OL-HDF has expanded.
View Article and Find Full Text PDFBackground: New haemodialysis therapeutic regimens are required to improve patient survival. Longer and more frequent dialysis sessions have produced excellent survival and clinical advantages, while online haemodiafiltration (OL-HDF) provides the most efficient form of dialysis treatment.
Methods: In this single-centre observational study, 57 patients on 4-5-hour thrice-weekly OL-HDF were switched to nocturnal every-other-day OL-HDF.