Background: Left ventricular assist devices (LVADs) improve survival, quality of life (QOL), and functional capacity (FC) among patients with end-stage heart failure. Few data are available regarding characteristics associated with QOL and FC response.
Methods And Results: Patients enrolled in the Heartmate II clinical trials that were alive with ongoing LVAD support at 6 months were included.
Curr Treat Options Cardiovasc Med
January 2016
The use of percutaneous, non-durable mechanical circulatory support (MCS) for cardiogenic shock (CS) is growing; however, large, randomized clinical trials confirming benefit in this population do not exist. Guidelines and recommendations regarding optimal timing for MCS implementation, patient selection, device selection, and post-implantation management are beginning to emerge. A better understanding of (1) the distinct hemodynamic effects of each device option, (2) the need for early implementation of the appropriate device option for a particular clinical scenario, (3) the definition of non-salvageable CS to help clinicians know when to say "no" to non-durable MCS, and (4) best practices to monitor, wean, and optimize metabolic parameters while using non-durable MCS are required to continue improving clinical outcomes for patients with CS.
View Article and Find Full Text PDFIntra-aortic balloon pump (IABP) counterpulsation is the most widely used mechanical circulatory support device because of its ease of use, low complication rate, and fast manner of insertion. Its benefit is still subject of debate, and a considerable gap exists between guidelines and clinical practice. Retrospective nonrandomized studies and animal experiments show benefits of IABP therapy.
View Article and Find Full Text PDFBackground: Right ventricular failure (RVF) increases morbidity and mortality. The RECOVER RIGHT study evaluated the safety and efficacy of a novel percutaneous right ventricular assist device, the Impella RP (Abiomed, Danvers, MA), in a prospective, multicenter trial.
Methods: Thirty patients with RVF refractory to medical treatment received the Impella RP device at 15 United States institutions.
Background: Heart failure (HF) involves myocardial fibrosis and dysregulated angiogenesis.
Objective: We explored whether biomarkers of fibrosis and angiogenesis correlate with HF severity.
Methods: Biomarkers of fibrosis [procollagen types I and III (PIP and P3NP), carboxyterminal-telopeptide of type I collagen (ICTP), matrix metalloproteases (MMP2 and MMP9), tissue inhibitor of MMP1 (TIMP1)]; and angiogenesis [placental growth factor (PGF), vascular endothelial growth factor (VEGF), soluble Fms-like tyrosine kinase-1 (sFlt1)] were measured in 52 HF patients and 19 controls.
Background: Right ventricular failure (RVF) is a major cause of morbidity and mortality after CF-LVAD implantation. We explored the association of pulmonary artery compliance (PAC), pulmonary artery elastance (PAE), and pulmonary artery pulsatility index (PAPi) in addition to established parameters as preoperative determinants of postoperative RVF after CF-LVAD surgery.
Methods And Results: We retrospectively reviewed 132 consecutive CF-LVAD implantations at Tufts Medical Center from 2008 to 2013.
Curr Probl Cardiol
December 2015
For the majority of patients with heart failure (HF) the management is non-surgical, but for the most advanced subgroup of patients with heart failure and reduced ejection fraction, mechanical circulatory support (MCS) is becoming a more viable treatment option. Heart transplantation is the 'gold standard' for advanced HF therapy, but is limited by donor organ availability. In contrast, MCS utilization has risen exponentially over the past decade.
View Article and Find Full Text PDFObjectives: This study tested the hypothesis that first reducing myocardial work by unloading the left ventricle (LV) with a novel intracorporeal axial flow catheter while delaying coronary reperfusion activates a myocardial protection program and reduces infarct size.
Background: Ischemic heart disease is a major cause of morbidity and mortality worldwide. Primary myocardial reperfusion remains the gold standard for the treatment of an acute myocardial infarction (AMI); however, ischemia-reperfusion injury contributes to residual myocardial damage and subsequent heart failure.
Cardiogenic shock is a common clinical condition with high in-hospital mortality. Early application of appropriate interventions for cardiogenic shock-including medical therapies, revascularization, temporary hemodynamic support devices, and durable mechanical circulatory support-may improve outcomes. The number and complexity of therapies for cardiogenic shock are increasing, making time-dependent decision-making more challenging.
View Article and Find Full Text PDFLeft ventricular assist device (LVAD) thrombosis is associated with high morbidity and mortality because of device malfunction, embolic events, and hemolysis. There remains uncertainty as to whether immediate device exchange versus an initial trial of anticoagulant and antiplatelet therapy is most appropriate in hemodynamically stable patients. We conducted a retrospective analysis of all LVAD implantations at a single center between January 2009 and June 2013 with follow-up through December 2013.
View Article and Find Full Text PDFAlthough historically the intra-aortic balloon pump has been the only mechanical circulatory support device available to clinicians, a number of new devices have become commercially available and have entered clinical practice. These include axial flow pumps, such as Impella(®); left atrial to femoral artery bypass pumps, specifically the TandemHeart; and new devices for institution of extracorporeal membrane oxygenation. These devices differ significantly in their hemodynamic effects, insertion, monitoring, and clinical applicability.
View Article and Find Full Text PDFBackground: Despite the emerging association between heart failure (HF) and inflammation, the role of T cells, major players in chronic inflammation, has only recently begun to be explored. Whether T-cell recruitment to the left ventricle (LV) participates in the development of HF requires further investigation to identify novel mechanisms that may serve for the design of alternative therapeutic interventions.
Methods And Results: Real-time videomicroscopy of T cells from nonischemic HF patients or from mice with HF induced by transverse aortic constriction revealed enhanced adhesion to activated vascular endothelial cells under flow conditions in vitro compared with T cells from healthy subjects or sham mice.
Although historically the intra-aortic balloon pump has been the only mechanical circulatory support device available to clinicians, a number of new devices have become commercially available and have entered clinical practice. These include axial flow pumps, such as Impella(®); left atrial to femoral artery bypass pumps, specifically the TandemHeart; and new devices for institution of extracorporeal membrane oxygenation. These devices differ significantly in their hemodynamic effects, insertion, monitoring, and clinical applicability.
View Article and Find Full Text PDFAlthough historically the intra-aortic balloon pump has been the only mechanical circulatory support device available to clinicians, a number of new devices have become commercially available and have entered clinical practice. These include axial flow pumps, such as Impella®; left atrial to femoral artery bypass pumps, specifically the TandemHeart; and new devices for institution of extracorporeal membrane oxygenation. These devices differ significantly in their hemodynamic effects, insertion, monitoring, and clinical applicability.
View Article and Find Full Text PDFThis article provides a brief summary of the relevant recommendations and references related to percutaneous mechanical circulatory support. The goal was to provide the clinician with concise, evidence-based contemporary recommendations, and the supporting documentation to encourage their application. The full text includes disclosure of all relevant relationships with industry for each writing committee member.
View Article and Find Full Text PDFObjective: Several recent trials have examined the clinical utility of intraaortic balloon counterpulsation pumps (IABPs) in cardiogenic shock and acute coronary syndromes. More recently, a larger-capacity 50 cc IABP was introduced into practice. No data comparing the hemodynamic effects of the 40 cc vs 50 cc IABP exist.
View Article and Find Full Text PDFHeart Fail Clin
April 2015
The use of surgically implanted durable mechanical circulatory support (MCS) in high-risk patients with heart failure is declining and short-term, nondurable MCS device use is growing. Percutaneously delivered MCS options for advanced heart failure include the intra-aortic balloon pump, Impella axial flow catheter, TandemHeart centrifugal pump, and venoarterial extracorporeal membrane oxygenation. Nondurable MCS devices have unique implantation characteristics and hemodynamic effects.
View Article and Find Full Text PDF