Although digital impression using an intraoral scanner (IOS) has been applied for removable partial denture (RPD) fabrication, it is still unclear how the morphology of a residual ridge recorded by digital impression would differ from that recorded by conventional impression. This in vivo study investigated the morphological difference in the recorded residual ridge between digital and conventional impressions. Vertical and horizontal displacements (VD and HD) in residual ridges recorded by digital and conventional impressions were assessed in 22 participants (15 female; mean age 78.
View Article and Find Full Text PDFPurpose: Although digital removable partial dentures have been previously described, there have been no reports on how to fabricate them in one piece. This study proposes a new method for fabricating patient-specific digital removable partial dentures using a custom plate.
Methods: First, a gypsum model was scanned using a laboratory scanner and a removable partial denture was designed using computer-aided design (CAD) software based on standard tessellation language data.
This study aimed to evaluate the retentive force of polyetheretherketone (PEEK) and zirconia secondary crowns on ready-made titanium implant abutments (with height, diameter, and taper as 5.5 mm, 4.5 mm, and 6°, respectively) as the primary crown.
View Article and Find Full Text PDFJ Mech Behav Biomed Mater
February 2023
Here, we tested the hypothesis that tensile and compressive stresses generated in the alveolar bone proper regulate site-specific cellular and functional changes in osteoclasts and osteoblasts. Thirty-two 13-week-old male mice were randomly divided into four groups: two experimental groups with vertical loading obliquely from the palatal side to the buccal side of the maxillary molar (0.9 N) 30 min per day for 8 or 15 days and unloaded controls (n = 8).
View Article and Find Full Text PDFThe aim of this study was to investigate the effect of scanning origin location on the data accuracy of removable partial denture (RPD) abutment teeth region in digital impressions acquired by an intraoral scanner. A mandibular partially edentulous model including the following target abutment teeth was used: the left second molar (#37); left first premolar (#34); and right second premolar (#45). The following scanning strategies were tested: the strategy starting from #37 to mesial direction (37M); strategies starting from #34 to mesial (34M) and distal directions (34D), and strategies starting from #45 to mesial (45M) and distal directions (45D).
View Article and Find Full Text PDFPurpose: Coronavirus disease 2019 has forced the use of remote education worldwide. In 2020, the authors conducted a fully digitized, remote flipped (RF) classroom focusing on removable partial dentures. This study aimed to evaluate the learning outcomes of the RF classroom and compare these with those of the on-site classroom.
View Article and Find Full Text PDFPurpose: We investigated and compared the stress distribution within one- and two-piece mini-implants for overdentures with three different attachments (ball, Locator, and magnet) and two different diameters using three-dimensional finite element (3D FE) analysis and a monotonic bending test. The goal was to identify the most beneficial implant attachment system design for mini-implant overdentures with a lower risk of implant fracture.
Methods: Twelve 3D FE models simulating a mandible segment with one- and two-piece mini-implants with different attachment systems, diameters, and overdentures were created using three-dimensional computer-aided design (CAD) software.
Purpose We aimed to assess removable partial denture occlusal rests composed of polyether-ether-ketone (PEEK) and zirconia, using finite element analysis.Methods Three-dimensional PEEK and zirconia rest models, including the occlusal rest (1.5 mm thickness at the basal portion, 3.
View Article and Find Full Text PDFThis study aimed to evaluate the effect of retention hole designs in artificial teeth on failure resistance of the connection with a thermoplastic denture base resin. Artificial teeth with the following retention hole designs were attached to polyester and polyamide resins: no hole, vertical hole, horizontal hole, and vertical and horizontal holes. An artificial tooth with no hole attached to polymethyl methacrylate was prepared as the control.
View Article and Find Full Text PDFTo evaluate the fracture resistance of computer-aided design and computer-assisted manufacturing restorations as the abutment of removable partial dentures, experimental blocks, with the rest seat made of feldspar, hybrid resin composite, lithium disilicate glass ceramic, or zirconia, were subjected to loading by a metallic occlusal rest. The rest contacted the rest seat with an accurate fit and two mismatch contact conditions: bottom and sidewall contact. Zirconia exhibited the highest fracture load, and the fracture load of the accurate fit was significantly higher than that of the sidewall contact (p<0.
View Article and Find Full Text PDFTo evaluate the flexural and fatigue properties of a polyester disk material used in milled resin clasps of removable partial dentures, experimental polyester disk (mPE), injection-molded polyester (iPE), and polymethyl methacrylate disk (mPMMA) were examined by three-point bending tests and cyclic fatigue tests at 0.75 or 1.50 mm deflection.
View Article and Find Full Text PDFPurpose: This study comprehensively reviewed the current status of the digital workflow of removable partial dentures (RPDs) and summarized information about the fabrication methods and material properties of the dental framework, artificial teeth, and denture base.
Study Selection: We performed a systematic review of the literature published in online databases from January 1980 to April 2020 regarding RPD fabrication and materials used in the related digital technology. We selected eligible articles, retrieved information regarding digital RPDs, and conducted qualitative/quantitative analyses.
Purpose: This study comprehensively reviewed the current status of digital workflows in fabricating removable partial dentures (RPDs) using evidence from clinical trials and case reports.
Study Selection: We performed a systematic review of the literature on the materials and fabrication of RPDs using digital technologies published in online databases from 1980 to 2020. We selected eligible articles from the search results, retrieved information on digital RPDs from these, and conducted a qualitative analysis.
The purpose of this study was to investigate the influence of retainers and major connector designs on the stabilization of remaining mobile teeth using removable partial dentures (RPDs). We prepared experimental RPDs with several retainer designs and major connectors for lower Kennedy class I models. The simulated RPD insertion and removal test was conducted and retentive force and mobility of mobile remaining teeth with and without RPD placement were measured throughout a simulation test.
View Article and Find Full Text PDFPurpose: The purpose of this study was to determine the effect of block-out preparation, used to eliminate the undercut area, on the retentive force and stress distribution of resin clasps.
Methods: A total of 72 polyester and polyamide resin clasps were fabricated on a premolar abutment crown following six block-out preparations. A combination of two types of vertical block-outs and three types of horizontal block-outs (on the missing side) was used on the abutment tooth.
The purpose of this study was to investigate the wear volume and the principal strain of machinable dental composite and ceramics in simulated mastication. A ball-on-disk wear test was performed for 3,000 cycles in water, using nine ball/disk combinations of three commercial CAD/CAM materials: feldspathic, lithium disilicate glass ceramics, and a highly loaded composite material (n = 7 for each combination). The wear volume was optically measured using a digital scanner and analyzed for statistical differences based on the materials (α = 0.
View Article and Find Full Text PDFStatement Of Problem: The optimum selection of denture teeth for patients with a reduced interarch distance has not been established.
Purpose: The purpose of this in vitro study was to investigate the influence of denture tooth material and thickness on the fracture resistance of thin acrylic resin denture bases.
Material And Methods: Acrylic resin (AC), composite resin (CO), or ceramic (CE) molar denture teeth were embedded in denture base blocks (2.
Purpose: Nonlinear finite element contact analysis is used to mathematically estimate stress and strain in a time- and status-dependent mechanical model. However, the benefits and limitations of this method have not been thoroughly examined.
Study Selection: The current review summarizes the utility of contact analysis in characterizing individual stressors: (1) tooth-to-tooth contact, (2) restorative interface, and (3) bone-implant integration.
The aim of this study was to assess the effect of high-pressure polymerization on mechanical properties of denture base resin. A heat-curing denture base resin and an experimental PMMA were polymerized under 500MPa of pressure by means of an isostatic pressurization machine at 70°C for 24h to make rectangular specimens whose dimensions were 30mm×2mm×2mm. Each specimen was deflected on a three-point flexural test until either fracture occurred or the sample was loaded up to 8mm in deflection.
View Article and Find Full Text PDFBackground: The effects of fish consumption and n-3 poly-unsaturated fatty acid (PUFA) levels on atopic disorders are inconsistent in previous reports, but few studies have investigated the effects of both fish and n-3 PUFA. The aim of the present study was to investigate whether erythrocyte fatty acids and the consumption of fish are associated with atopic diseases in pre- and early adolescents.
Methods: A total of 135 students with eczema, 136 students with asthma, and 137 healthy control students were selected from fifth and eighth grades in Shunan, Japan.
This study aimed to introduce a procedure for determining the bilinear elastic moduli (E1 and E2) of the periodontal ligament for a mathematical tooth model to analyse stress in the mandible. The bone and tooth morphology were scanned from a dry skull and an extracted intact tooth, respectively, and reconstructed in a three-dimensional finite element model. The model showed good agreement with previously reported in vivo premolar movement when an E1 for the first phase tooth movement of 0.
View Article and Find Full Text PDF