Publications by authors named "Nathaniel S Lee"

Ultrahigh-performance liquid chromatography using positive electrospray ionization and quadrupole orbital ion trap high-resolution mass spectrometry was evaluated for analyzing mycotoxins in finished cereal and nut products. Optimizing the orbital ion trap mass analyzer in full-scan mode using mycotoxin-fortified matrix extracts gave mass accuracies, δM, of < ± 2.0 ppm at 70,000 full width at half maximum (FWHM) mass resolution (RFWHM).

View Article and Find Full Text PDF

Mycotoxins in foods have long been recognized as potential health hazards due to their toxic and carcinogenic properties. A simple and rapid method was developed to detect 26 mycotoxins (aflatoxins, ochratoxins, fumonisins, trichothecenes, and ergot alkaloids) in corn, rice, wheat, almond, peanut, and pistachio products using high-performance liquid chromatography-triple-quadrupole mass spectrometry. Test portions of homogenized grain or nut products were extracted with acetonitrile/water (85:15, v/v), followed by high-speed centrifugation and dilution with water.

View Article and Find Full Text PDF

Dietary supplements form an increasing part of the American diet, yet broadly applicable multiresidue pesticide methods have not been evaluated for many of these supplements. A method for the analysis of 310 pesticides, isomers, and pesticide metabolites in dried botanical dietary supplements has been developed and validated. Sample preparation involved acetonitrile:water added to the botanical along with anhydrous magnesium sulfate and sodium chloride for extraction, followed by cleanup with solid-phase extraction using a tandem cartridge consisting of graphitized carbon black (GCB) and primary-secondary amine sorbent (PSA).

View Article and Find Full Text PDF

A multiresidue method analyzing 209 pesticides in 24 agricultural commodities has been developed and validated using the original Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) procedure and high performance liquid chromatography-positive electrospray ionization-tandem mass spectrometry (LC-MS/MS) analysis. Using solvent-only calibration standards (SOCSs) and matrix-matched calibration standards (MMCSs), it was demonstrated that a minimal concentration of 5-10 μg/kg (part per billion, ppb) of analytes in matrix is required for the consistent identification of targeted pesticides with two MRM transitions. Method performance was validated by the precision and accuracy results obtained from fortification studies at 10, 25, 100, and 500 ppb and MMCSs.

View Article and Find Full Text PDF