Recent advances in automation have fostered the development of unattended data collection services at a handful of synchrotron facilities worldwide. At the Swiss Light Source, the installation of new high-throughput sample changers at all three macromolecular crystallography beamlines and the commissioning of the Fast Fragment and Compound Screening pipeline created a unique opportunity to automate data acquisition. Here, the DA+ microservice software stack upgrades, implementation of an automatic loop-centering service and deployment of the Smart Digital User (SDU) software for unattended data collection are reported.
View Article and Find Full Text PDFActa Crystallogr D Struct Biol
March 2022
Over the last two decades, fragment-based drug discovery (FBDD) has emerged as an effective and efficient method to identify new chemical scaffolds for the development of lead compounds. X-ray crystallography can be used in FBDD as a tool to validate and develop fragments identified as binders by other methods. However, it is also often used with great success as a primary screening technique.
View Article and Find Full Text PDFThe serial X-ray crystallography method was developed to ease the handling of small fragile crystals of membrane proteins and for rapid data collection on hundreds of microcrystals directly in the growth medium without the need for crystal harvesting. To facilitate mounting of these samples on a goniometer at cryogenic or at room temperatures, two new 3D-printed holders have been developed. They provide for cubic and sponge phase sample stability in the X-ray beam and are compatible with sample-changing robots.
View Article and Find Full Text PDFIn this paper, the design and functionalities of the high-throughput TELL sample exchange system for macromolecular crystallography is presented. TELL was developed at the Paul Scherrer Institute with a focus on speed, storage capacity and reliability to serve the three macromolecular crystallography beamlines of the Swiss Light Source, as well as the SwissMX instrument at SwissFEL.
View Article and Find Full Text PDFObjective: To investigate diagnostic accuracy in patient histories involving nonspecific complaints and the extent to which characteristics of physicians and structural properties of patient histories are associated with accuracy.
Methods: Six histories of patients presenting to the emergency department (ED) with nonspecific complaints were provided to 112 physicians: 36 ED physicians, 50 internists, and 26 family practitioners. Physicians listed the 3 most likely diagnoses for each history and indicated which cue(s) they considered crucial.