Polymer ring stent grafts from Endologix are reliable to treat challenging abdominal aortic aneurysm anatomy (hostile neck and tortuous or narrow iliac arteries). Rare cases of anaphylactoid reactions have been reported during the filing time of the graft rings due to polymer leakage. Management with amines, an antihistamine drug, and supportive care quickly stabilized both of our patients, which permitted the continuation and completion of their surgery.
View Article and Find Full Text PDFBackground: Given the importance in prevention of lower extremity amputations (LEAs) associated with diabetes or peripheral artery disease (PAD), we sought to document the trends of primary LEA in Québec, Canada, from years 2006 to 2019.
Methods: Using the Québec Integrated Chronic Disease Surveillance System, we calculated crude and age-standardized annual incidence rates of primary LEA associated with diabetes and PAD among adults ≥ 40 years (99% confidence intervals [CI]), and all-cause 1-year mortality proportion trends following a primary LEA (95% CI), stratified by minor or major as the highest level of LEA during the same hospital stay and age groups. Trends were assessed using multivariate regression models.
Background: ChAdOx1 nCoV-19 (AstraZeneca) and Ad26COV2.S (Johnson & Johnson/Janssen) adenoviral vector vaccines have been associated with vaccine-induced immune thrombotic thrombocytopenia (VITT). Arterial thrombosis and acute limb ischemia have been described in a minority of patients with VITT.
View Article and Find Full Text PDFRecognising the challenges and limitations of current methodologies to predict highway runoff concentrations, this paper presents a novel approach based on the derivation of pollutant emission factors for twelve different types of vehicle. Published emission factor data and properties of differing vehicles types are combined with annual average daily traffic volume (AADT), highway characteristics and rainfall data to determine the pollutant distributions associated with differing highway and traffic types. In this paper, the method is applied to 126 sections of highway in the Greater London Borough of Enfield (United Kingdom; UK) and results are comparable with values reported in the literature.
View Article and Find Full Text PDFJ Vasc Surg Cases Innov Tech
December 2020
An aortoduodenal fistula is a rare complication of endovascular aortic aneurysm repair. Q fever infection is known for its vascular tropism, and arterial fistulas have been reported in association with infections. We report the case of a 78-year-old patient who had developed an aortoduodenal fistula secondary to vascular Q fever 5 years after he had been treated with an aortic endograft.
View Article and Find Full Text PDFObjectives: In this exploratory study, we wanted to know how evaluators differentiate collaborative approaches to evaluation (CAE) perceived to be successful from those perceived to be less-than-successful.
Method: In an online questionnaire survey, we obtained 320 responses from evaluators who practice CAE (i.e.
Background: The migratory patterns of animals are changing in response to global environmental change with many species forming resident populations in areas where they were once migratory. The white stork (Ciconia ciconia) was wholly migratory in Europe but recently guaranteed, year-round food from landfill sites has facilitated the establishment of resident populations in Iberia. In this study 17 resident white storks were fitted with GPS/GSM data loggers (including accelerometer) and tracked for 9.
View Article and Find Full Text PDFResearch on evaluation capacity is limited although a recent survey article on integrating evaluation into the organizational culture (Cousins, Goh, Clark, & Lee, 2004) revealed that interest in the topic is increasing. While knowledge about building the capacity to do evaluation has developed considerably, less is understood about building the organizational capacity to use evaluation. This article reports on the results of a pan-Canadian survey of evaluators working in organizations (internal evaluators or organization members with evaluation responsibility) conducted in 2007.
View Article and Find Full Text PDFJ Long Term Eff Med Implants
April 2014
In this study, we aimed to investigate changes to the fabric of Talent stent-grafts following implantation of aortic endografts and to determine the possible causes of fatigue and/or failure of the grafts. Six devices were explanted at reoperation (N=5) and autopsy (N=1). Selected segments were assessed nondestructively by gross observation and destructively by analyzing textile characteristics and chemical properties.
View Article and Find Full Text PDFThe biodurability of the Nitinol wires used in stent-grafts retrieved from reoperations and autopsy was analyzed to assess the possible causes of fracture and/or corrosion of the stents. The Nitinol wires of six explanted devices presented a corrosion-free surface after in vivo service. The drawing lines in the control wires were still present, but neither burrs nor flakes were observed.
View Article and Find Full Text PDFJ Long Term Eff Med Implants
April 2014
Using the retrieved devices from one autopsy and five reoperations, the biocompatibility of explanted Talent stent-grafts was investigated to highlight the capacity of the fabric to act as an effective scaffold to regenerate a blood conduit. The autopsy device was encapsulated both internally and externally, but the capsules did not penetrate through the fabric structure. The reoperation devices showed discrete patches of compact fibrin and irregularly scattered mural thrombi.
View Article and Find Full Text PDFJ Long Term Eff Med Implants
August 2012
Six Talent stent-grafts were harvested at reoperations (N=5) and autopsy (N=1). The explants were observed nondestructively, including gross morphology, X-rays, CT scans and closed pressure system analysis. The Nitinol frames in three devices harvested at reoperations and another harvested at autopsy were intact.
View Article and Find Full Text PDFA microporous and permeable wall is important for the healing of vascular prostheses, however, the significance of its permeability to soluble substances at subcellular level has not been demonstrated. Polyester arterial prostheses were prepared in such a way that each of them contained three segments, of which at least one segment was impervious and another segment was permeable to water but impermeable to cells. Twenty graft segments were implanted in 7 dogs as a thoraco-abdominal bypass for 2 months.
View Article and Find Full Text PDF