A novel image-reconstruction method is proposed for the processing of data acquired at random spatial positions. The images are reconstructed and updated in real time concurrently with the measurements to produce an evolving image, the quality of which is continuously improving and converging as the number of data points increases with the stream of additional measurements. It is shown that the images converge to those obtained with data acquired on a uniformly sampled surface, where the sampling density satisfies the Nyquist limit.
View Article and Find Full Text PDFBackground: Postpartum hemorrhage (PPH) is the leading cause of maternal death worldwide. The World Maternal Antifibrinolytic trial showed that antifibrinolytic tranexamic acid (TXA) reduces PPH deaths. Maternal anemia increases the risk of PPH.
View Article and Find Full Text PDFWe present the design and the performance evaluation of a new interconnect for large-scale densely packed electronically scanned antenna arrays that utilize a high-speed digital board-to-board vertical connector. The application targets microwave tissue, imaging in the frequency range from 3 GHz to 8 GHz. The tissue-imaging arrays consist of hundreds of active antenna elements, which require low-reflection, low-loss, and low-crosstalk connections to their respective receiving and transmitting circuits.
View Article and Find Full Text PDFIntroduction: The composition of thrombi determines their structure, mechanical stability, susceptibility to lysis, and consequently, the clinical outcome in coronary artery disease (CAD), acute ischemic stroke (AIS), and peripheral artery disease (PAD). Fibrin forms the primary matrix of thrombi intertwined with DNA, derived from neutrophil extracellular traps (NETs), and von Willebrand factor (VWF) bridging DNA and platelets. Here we examined the relative content of fibrin, DNA and VWF in thrombi and analyzed their interrelations and quantitative associations with systemic biomarkers of inflammation and clinical characteristics of the patients.
View Article and Find Full Text PDFMillimeter wave (MMW) technology is expanding rapidly into security screening for dangerous items concealed under clothing. It uses safe non-ionizing radiation and penetrates clothing well. We present a new planar system at Ka band for the three-dimensional simultaneous imaging of both sides of an inspected person where the images are produced in real time by a recently proposed generalized holographic reconstruction algorithm.
View Article and Find Full Text PDFA prototype of a bias-switched active sensor was developed and measured to establish the achievable dynamic range in a new generation of active arrays for microwave tissue imaging. The sensor integrates a printed slot antenna, a low-noise amplifier (LNA) and an active mixer in a single unit, which is sufficiently small to enable inter-sensor separation distance as small as 12 mm. The sensor’s input covers the bandwidth from 3 GHz to 7.
View Article and Find Full Text PDFIntroduction: Fibrin structure and cellular composition of thrombi profoundly affect the clinical outcomes in ischemic coronary and peripheral artery disease. Our study addressed the interrelations of structural features of thrombi and routinely measured laboratory parameters.
Materials And Methods: Thrombi removed by thromboaspiration following acute myocardial infarction (n=101) or thrombendarterectomy of peripheral arteries (n=50) were processed by scanning electron microscopy and immunostaining for fibrin and platelet antigen GPIIb/IIIa to determine fibrin fibre diameter and relative occupancy by fibrin and cells.
Int J Biomed Imaging
August 2012
This study compared the inconsistent responding validity scales of the Personality Assessment Inventory (PAI) and the Psychopathic Personality Inventory (PPI)/PPI-Revised (PPI-R) in two correctional samples to determine the extent to which they overlap in identifying invalid profiles. Results revealed substantial differences in the way the inconsistent responding validity scales of these measures performed. In particular, the PAI identified far fewer participants as having responded inconsistently compared with the PPI/PPI-R.
View Article and Find Full Text PDFProgress curve analysis is a convenient tool for the characterization of enzyme action: a single reaction mixture provides multiple experimental measured points for continuously varying amounts of substrates and products with exactly the same enzyme and modulator concentrations. The determination of kinetic parameters from the progress curves, however, requires complex mathematical evaluation of the time-course data. Some freely available programs (e.
View Article and Find Full Text PDFPhys Rev E Stat Nonlin Soft Matter Phys
January 2005
Nonradiating electromagnetic sources are sources whose field is identically zero outside of their volume. They are undetectable unless the observation point is in direct contact with them. They are the basis of the theory of source equivalence, which studies the field invariance with respect to source transformations.
View Article and Find Full Text PDF