Nowadays, the scientific community and industry are increasingly pressed to provide solutions for developing compact and highly-performing trace-gas sensors for several applications of crucial importance, such as environmental monitoring or medical diagnostics. In this context, this work describes a novel configuration, making use of a mid-IR spectrophone combining the compactness of a photo-acoustic setup, a non-conventional micro-electro-mechanical (MEMS) acousto-to-voltage transducer, and the sensitivity enhancement given by a cost-effective and easy-to-build dual-tube resonator configuration. In the optimal condition of sample pressure, the system developed in this work can achieve a minimum detection limit (MDL) equal to 0.
View Article and Find Full Text PDFSince the beginning of this millennium, frequency comb generators have reshaped frequency metrology and related areas. After more than two decades since their first realization, several other ways to generate frequency combs, in any spectral region, have been demonstrated, each way with its peculiar features. This trend has triggered the need to quantitatively assess how close the new comb realizations are to an ideal comb, a feature that will be called combness throughout this paper.
View Article and Find Full Text PDFIn a comment to our recent publication, Nicholls question our results and interpretation based on theoretical arguments that reveal a profound misunderstanding of our publication.
View Article and Find Full Text PDFEukaryotic cell function and survival rely on the use of a mitochondrial H electrochemical gradient (Δp), which is composed of an inner mitochondrial membrane (IMM) potential (ΔΨmt) and a pH gradient (ΔpH). So far, ΔΨmt has been assumed to be composed exclusively of H. Here, using a rainbow of mitochondrial and nuclear genetic models, we have discovered that a Na gradient equates with the H gradient and controls half of ΔΨmt in coupled-respiring mammalian mitochondria.
View Article and Find Full Text PDFAims: To compare the efficacy and safety of different hybrid closed loop (HCL) systems in people with diabetes through a network meta-analysis.
Methods: We searched MEDLINE, EMBASE, CENTRAL and PubMed for randomised clinical trials (RCTs) enrolling children, adolescents and/or adults with type 1 or type 2 diabetes, evaluating Minimed 670G, Minimed 780G, Control-IQ, CamAPS Fx, DBLG-1, DBLHU, and Omnipod 5 HCL systems against other types of insulin therapy, and reporting time in target range (TIR) as outcome.
Results: A total of 28 RCTs, all enrolling people with type 1 diabetes, were included.
Background: The comparative effects of specific blood pressure (BP) lowering treatments on patient-important outcomes following kidney transplantation are uncertain. Our 2009 Cochrane review found that calcium channel blockers (CCBs) improved graft function and prevented graft loss, while the evidence for other BP-lowering treatments was limited. This is an update of the 2009 Cochrane review.
View Article and Find Full Text PDFProc Natl Acad Sci U S A
July 2024
Mitofusins (Mfn1 and Mfn2) are the mitochondrial outer-membrane fusion proteins in mammals and belong to the dynamin superfamily of multidomain GTPases. Recent structural studies of truncated variants lacking alpha helical transmembrane domains suggested that Mfns dimerize to promote the approximation and the fusion of the mitochondrial outer membranes upon the hydrolysis of guanine 5'-triphosphate disodium salt (GTP). However, next to the presence of GTP, the fusion activity seems to require multiple regulatory factors that control the dynamics and kinetics of mitochondrial fusion through the formation of Mfn1-Mfn2 heterodimers.
View Article and Find Full Text PDFThe real-time monitoring of densely populated areas with high seismic and volcanic risk is of crucial importance for the safety of people and infrastructures. When an earthquake occurs, the Earth surface experiences both translational and rotational motions. The latter are usually not monitored, but their measurement and characterization are essential for a full description of the ground motion.
View Article and Find Full Text PDFBackground: Guidelines suggest that adults with diabetes and kidney disease receive treatment with angiotensin-converting-enzyme inhibitors (ACEi) or angiotensin receptor blockers (ARB). This is an update of a Cochrane review published in 2006.
Objectives: We compared the efficacy and safety of ACEi and ARB therapy (either as monotherapy or in combination) on cardiovascular and kidney outcomes in adults with diabetes and kidney disease.
We report on the generation of twin beams through a cascaded process of optical parametric oscillation in a doubly resonant second-harmonic generation system. These bright beams exhibit strong quantum correlations, enabling the observation of up to 5 dB of noise reduction in their intensity difference below the standard quantum limit.
View Article and Find Full Text PDFMany precision applications in the mid-infrared spectral range have strong constraints based on quantum effects that are expressed in particular noise characteristics. They limit, e.g.
View Article and Find Full Text PDFObjective: This study aimed to assess the prevalence and types of oral adverse events following immunization (AEFIs) in people who received at least one dose of any type of vaccine.
Materials And Methods: We conducted a bibliographic search about oral AEFIs in MEDLINE, Embase, PubMed, and Ovid from database inception to November 07, 2022. Risk of bias was assessed using the MURAD or the Quality In Prognosis Studies tools.
Objective: Hypertension affects 50-90% of kidney transplant recipients and is associated with cardiovascular disease and graft loss. We aimed to evaluate the comparative benefits and harms of blood pressure lowering agents in people with a functioning kidney transplant.
Methods: We conducted a systematic review with network meta-analysis of randomized controlled trials (RCTs).
Cochrane Database Syst Rev
January 2024
Background: Haemodialysis (HD) requires safe and effective anticoagulation to prevent clot formation within the extracorporeal circuit during dialysis treatments to enable adequate dialysis and minimise adverse events, including major bleeding. Low molecular weight heparin (LMWH) may provide a more predictable dose, reliable anticoagulant effects and be simpler to administer than unfractionated heparin (UFH) for HD anticoagulation, but may accumulate in the kidneys and lead to bleeding.
Objectives: To assess the efficacy and safety of anticoagulation strategies (including both heparin and non-heparin drugs) for long-term HD in people with kidney failure.
Photoacoustic dual-comb spectroscopy (DCS), converting spectral information in the optical frequency domain to the audio frequency domain via multi-heterodyne beating, enables background-free spectral measurements with high resolution and broad bandwidth. However, the detection sensitivity remains limited due to the low power of individual comb lines and the lack of broadband acoustic resonators. Here, we develop cavity-enhanced photoacoustic DCS, which overcomes these limitations by using a high-finesse optical cavity for the power amplification of dual-frequency combs and a broadband acoustic resonator with a flat-top frequency response.
View Article and Find Full Text PDFBackground: Percutaneous renal biopsy (PRB) may subject patients to emotional distress and pain before and during the biopsy. The aim of this study was to evaluate the effects of complementary/non-pharmacological interventions such as music therapy (MT) on anxiety, pain and satisfaction in renal patients undergoing PRB.
Methods: A prospective, single-centre, single-blind, randomized controlled two-arm trial was conducted.
Mid-infrared frequency combs are nowadays well-appreciated sources for spectroscopy and frequency metrology. Here, a comprehensive approach for characterizing a difference-frequency-generated mid-infrared frequency comb (DFG-comb) both in the time and in the frequency domain is presented. An autocorrelation scheme exploiting mid-infrared two-photon detection is used for characterizing the pulse width and to verify the optimal compression of the generated pulses reaching a pulse duration (FWHM) as low as 196 fs.
View Article and Find Full Text PDF