Purpose: Peptide receptor radionuclide therapy (PRRT) is mostly administered using a fixed injected activity (IA) per cycle. This empiric regime results in highly variable absorbed doses to the critical organs and undertreatment of the majority of patients. We conceived a personalized PRRT protocol in which the IA is adjusted to deliver a prescribed absorbed dose to the kidney, with the aim to safely increase tumour irradiation.
View Article and Find Full Text PDFBackground: Routine dosimetry is essential for personalized Lu-octreotate peptide receptor radionuclide therapy (PRRT) of neuroendocrine tumors (NETs), but practical and robust dosimetry methods are needed for wide clinical adoption. The aim of this study was to assess the accuracy and inter-observer reproducibility of simplified dosimetry protocols based on quantitative single-photon emission computed tomography (QSPECT) with a limited number of scanning time points. We also updated our personalized injected activity (IA) prescription scheme.