Uncertainties in the steps of external beam radiotherapy (EBRT) affect patient outcomes. However, few studies have investigated major contributors to these uncertainties. This study investigated factors contributing to reducing uncertainty in delivering a dose to a target volume.
View Article and Find Full Text PDFRadiat Prot Dosimetry
December 2023
This study aimed to obtain reference dosimetry practices for flattened photon and electron beams. A questionnaire survey on these practices was sent to 37 facilities that performed radiotherapy using these beams in Fukui, Ishikawa, Niigata and Toyama, Japan. The survey comprised equipment (dosemeters, water phantoms, thermometers, barometers and hygrometers) and procedures for reference dosimetry (water used as the phantoms, verification of chamber placement, periodic checks of ion recombination- and polarity-corrections, pre-irradiation and relative humidity monitoring).
View Article and Find Full Text PDFCoronavirus disease (COVID-19) vaccination is known to cause a diagnostic dilemma due to false-positive findings on [F]FDG PET in vaccine-associated hypermetabolic lymphadenopathy. We present two case reports of women with estrogen-receptor (ER)-positive cancer of the breast who were vaccinated for COVID-19 in the deltoid muscle. [F]FDG positron emission tomography (PET) demonstrated primary breast cancer and multiple axillary lymph nodes with increased [F]FDG uptake, diagnosed as vaccine-associated [F]FDG-avid lymph nodes.
View Article and Find Full Text PDFThis study aimed to evaluate changes in the deformation of the entrance window on a phantom for a horizontal beam geometry with a window thickness of 5 mm. The window deformation over time was measured using a dial indicator for 12 h after water filling. The window deformation was in the range of 0.
View Article and Find Full Text PDFPurpose: Medical physicists use a suitable detector connected to an electrometer to measure radiotherapy beams. Each detector and electrometer has a lifetime (due to physical deterioration of detector components and electrical characteristic deterioration in electronic electrometer components), long-term stability [according to IEC 60731:2011, ≤0.5% (reference-class dosimeter)], and calibration frequency [according to Muir et al.
View Article and Find Full Text PDFVarious attempts have been made to elucidate the development patterns in the spontaneous movements of infants through longitudinal evaluations. Movement complexity has been found to demonstrate u-shaped changes in the measurements focusing on limb movements. However, researchers have not yet clarified how other characteristics, besides movement complexity, change over time.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
August 2019
Purpose: Phantoms for horizontal beam geometry can avoid issues in vertical-beam geometry, such as change in chamber depth due to evaporation, and defining the origin at the water surface. However, their thin entrance windows would deform when these phantoms are filled, which can change the chamber depth, as pointed out by The International Atomic Energy Agency (IAEA) TRS-398. Currently, few reports (Arib et al.
View Article and Find Full Text PDFRep Pract Oncol Radiother
March 2018
Background: Uncertainty in the calibration of high-energy radiation sources is dependent on user and equipment type.
Aim: We evaluated the uncertainty in the positioning of a cylindrical chamber at a reference depth for reference dosimetry of high-energy photon beams and the resulting uncertainty in the chamber readings for 6- and 10-MV photon beams. The aim was to investigate major contributions to the positioning uncertainty to reduce the uncertainty in calibration for external photon beam radiotherapy.
Nihon Hoshasen Gijutsu Gakkai Zasshi
March 2018
The American Association of Physicists in Medicine (AAPM) Working Group on TG-51 published an Addendum to the AAPM's TG-51 protocol (Addendum to TG-51) in 2014, and the Japan Society of Medical Physics (JSMP) published a new dosimetry protocol JSMP 12 in 2012. In this study, we compared the absorbed dose to water determined at the reference depth for high-energy photon beams following the recommendations given in AAPM TG-51 and the Addendum to TG-51, IAEA TRS-398, and JSMP 12. This study was performed using measurements with flattened photon beams with nominal energies of 6 and 10 MV.
View Article and Find Full Text PDFThe optimization of enzyme-mediated calcite precipitation was evaluated as a soil-improvement technique. In our previous works, purified urease was utilized to bio-catalyze the hydrolysis of urea, which causes the supplied Ca(2+) to precipitate with [Formula: see text] as calcium carbonate. In the present work, magnesium chloride was newly added to the injecting solutions to delay the reaction rate and to enhance the amount of carbonate precipitation.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
September 2014
The uncertainty of the beam quality conversion factor (k(Q,Q0)) of standard dosimetry of absorbed dose to water in external beam radiotherapy 12 (JSMP12) is determined by combining the uncertainty of each beam quality conversion factor calculated for each type of ionization chamber. However, there is no guarantee that ionization chambers of the same type have the same structure and thickness, so there may be individual variations. We evaluated the uncertainty of k(Q,Q0) for JSMP12 using an ionization chamber dosimeter and linear accelerator without a specific device or technique in consideration of the individual variation of ionization chambers and in clinical radiation field.
View Article and Find Full Text PDFIn standard external beam radiotherapy dosimetry, which is based on absorbed dose by water, the absorbed dose at any calibration depth is calculated using the same beam quality conversion factor, regardless of the presence or absence of a waterproofing sleeve. In this study, we evaluated whether there were differences between absorbed doses at calibration depths calculated using a beam quality conversion factor including a wall correction factor that corresponds to a waterproofing sleeve thickness of 0.3 mm, and without a waterproofing sleeve.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
March 2013
A comparison of absorbed doses to water at a calibration depth determined by Japan Society of Medical Physics (JSMP) 12 and 01 was conducted, using a farmer type ionization chamber. The absorbed dose to water calibration factor (ND,W,Q0) and beam quality conversion factor (kQ,Q0) for JSMP 12 were smaller than the absorbed dose to water calibration factor and beam quality conversion factor for JSMP 01. Differences in absorbed doses at a calibration depth were -0.
View Article and Find Full Text PDFEpidermal growth factor receptor (EGFR) is commonly overexpressed in malignant pleural mesothelioma (MPM). Cetuximab is a chimeric mouse-human antibody targeted against EGFR and induces potent antibody-dependent cellular cytotoxicity (ADCC). The action of cetuximab against MPM cells has not been well studied.
View Article and Find Full Text PDFUL16-binding protein 2 (ULBP2) is one of the ligands for NKG2D (NKG2DL). ULBP2 expression is induced in transformed cells and is recognized by immune effector cells via the activating NKG2D immunoreceptor. Soluble forms of NKG2DL have been reported in the serum of patients with several types of cancer.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
March 2010
Kim introduced the geometric weighting factor concept into the field mapping method, and estimated collimator scatter factors of rectangular fields by correcting collimator exchange effects. The source plane is present at a specific position in the field mapping method, and, accordingly, the geometric weighting factor is constant. In this study, we changed the position of the source plane based on the measurement results, and we estimated the collimator factors of rectangular fields using the field mapping method.
View Article and Find Full Text PDF