Objectives: There is insufficient information about the effects of the thickness of externally characterized stains or glazes on CIELAB color parameters and the translucency parameter (TP) of 5 mol% yttria partially stabilized zirconia (5Y-PSZ). The present study evaluated the effect of a thickness reduction of the externally characterized or glazed layer on its CIE2000 color parameters and TP of 5Y-PSZ.
Materials And Methods: Twenty-eight specimens were sectioned from 5Y-PSZ blanks.
This study aimed to evaluate the effect of retention hole designs in artificial teeth on failure resistance of the connection with a thermoplastic denture base resin. Artificial teeth with the following retention hole designs were attached to polyester and polyamide resins: no hole, vertical hole, horizontal hole, and vertical and horizontal holes. An artificial tooth with no hole attached to polymethyl methacrylate was prepared as the control.
View Article and Find Full Text PDFTo evaluate the fracture resistance of computer-aided design and computer-assisted manufacturing restorations as the abutment of removable partial dentures, experimental blocks, with the rest seat made of feldspar, hybrid resin composite, lithium disilicate glass ceramic, or zirconia, were subjected to loading by a metallic occlusal rest. The rest contacted the rest seat with an accurate fit and two mismatch contact conditions: bottom and sidewall contact. Zirconia exhibited the highest fracture load, and the fracture load of the accurate fit was significantly higher than that of the sidewall contact (p<0.
View Article and Find Full Text PDFObjectives: The effect of toothbrushing on the color, relative translucency, and surface roughness of extrinsically stained zirconia dental restorations is still unclear. The purpose of the present study was to evaluate the optical properties and surface textures of extrinsically stained or glazed partially stabilized zirconia with 5 mol% yttria (5Y-PSZ) after toothbrushing by determining changes in the color, translucency parameter (TP), and surface roughness.
Materials And Methods: Specimens (2 mm thick; n = 50) were sectioned from 5Y-PSZ blanks.
To evaluate the flexural and fatigue properties of a polyester disk material used in milled resin clasps of removable partial dentures, experimental polyester disk (mPE), injection-molded polyester (iPE), and polymethyl methacrylate disk (mPMMA) were examined by three-point bending tests and cyclic fatigue tests at 0.75 or 1.50 mm deflection.
View Article and Find Full Text PDFStatement Of Problem: The lost-wax technique is commonly used for fabricating partial fixed dental prostheses. The casting patterns can be fabricated by using vat photopolymerization (a type of additive manufacturing), but the adaptation of these casting patterns has not been elucidated.
Purpose: The purpose of this in vitro study was to evaluate the effect of build orientation on the adaptation of casting patterns fabricated by digital light projection (DLP).
Face guards (FGs) are protectors that allow for the rapid and safe return of athletes who are to play after sustaining traumatic facial injuries and orbital fractures. Current FGs require significant thickness to achieve sufficient shock absorption abilities. However, their weight and thickness render the FGs uncomfortable and reduce the field of vision of the athlete, thus hindering their performance.
View Article and Find Full Text PDFThe aim of the present study was to evaluate the effects of build conditions and angle acuteness on edge reproducibility of the casting patterns fabricated using a digital light process. The prism-shaped patterns with various vertex angles were fabricated in three build orientations. The height from the base to the vertex angle point of the fabricated pattern was measured and the incomplete height was calculated as the discrepancy between the original and measured heights.
View Article and Find Full Text PDFA fiberglass-reinforced composite resin (FRP) block using a plain woven fiberglass sheet for CAD/CAM has been introduced in dental practice. The aim of the present study was to evaluate the effects of the fiberglass sheet orientation on the flexural properties of an FRP block. The flexural properties of five types of fiberglass sheet-assigned specimens were examined using a three-point bending test.
View Article and Find Full Text PDFThis study aimed to evaluate the shock absorption ability of trial face guards (FGs) incorporating a glass-fiber-reinforced thermoplastic (GF) and buffering space. The mechanical properties of 3.2 mm and 1.
View Article and Find Full Text PDFWe investigated the effects of incorporation of surface pre-reacted glass ionomer (S-PRG) filler in tissue conditioner (TC) on Candida albicans adhesion. We prepared specimens containing 0, 5, 10, or 20 wt% of S-PRG filler, and measured the amount of C. albicans on the surface using a colony forming unit (CFU) assay and scanning electron microscopic images.
View Article and Find Full Text PDFThe present study evaluated the flexural properties of a new temporary splint material, G-Fix, for use in dental trauma splints in comparison with other resin materials. Four types of resin materials were considered in the present study: MI Flow II, light-cured composite resin (MI); G-Fix, light-cured resin for splinting teeth (GF); Super-Bond C&B, adhesive resin cement (SB); and Unifast III, self-cured methyl-methacrylate resin (UF). The flexural properties of these four materials were tested according to ISO 4049.
View Article and Find Full Text PDFAim of this study was to investigate the effect of long-time immersion of soft denture liners in 37°C water on viscoelastic properties. Six silicone-based and two acrylic resin-based soft denture liners were selected. Cylindrical specimens were stored in distilled water at 37°C for 6 months.
View Article and Find Full Text PDFObjectives: This study evaluated color differences (Δs) and translucency parameter changes (Δs) of various computer-aided design/computer-aided manufacturing (CAD/CAM) blocks after immersion in coffee.
Materials And Methods: Eight CAD/CAM blocks and four restorative composite resins were evaluated. The CIE values of 2.
This study compared commercial composite resin blocks with one ceramic block for use in computer-aided design/computer aided manufacturing (CAD/CAM). Four composite resins, one composite ceramic, and one feldspar-ceramic block were investigated. Flexural strength (FS), flexural modulus (FM), and Vickers hardness (VH) were determined under three conditions: dry storage; immersion in water at 37°C for 7 days; and immersion in water at 37°C for 7 days followed by 10,000 thermocycles.
View Article and Find Full Text PDFObjectives: The objective of this study was to evaluate the effect of immersion time of restorative glass ionomer cements (GICs) and immersion duration in calcium chloride (CaCl2) solution on the surface hardness.
Methods: Two high-viscosity GICs, Fuji IX GP and GlasIonomer FX-II, were selected. Forty-eight specimens were randomly divided into two groups.
Purpose: To analyze on scanning electron microscopy (SEM) pictures from eight composite resins, taken in the centers of the initial, the middle and the terminal thirds of in vitro produced wear tracks morphological features to explain causative mechanisms for the material wear observed under two- and three-body wear.
Materials And Methods: In vitro wear behavior of eight composite resins, three conventional and five nanofiller containing marketed products was evaluated using a custom-made Zr-ball-on-disk sliding device. The composite specimens were subjected to 50,000 one-way sliding cycles (1.
The aim of this study was to evaluate the effects of ultraviolet light (UV) irradiation and sandblasting treatment on the shear bond strength between polyamide and chemical-cured resin. Three types of commercial polyamides were treated using UV irradiation, sandblasting treatment, and a combining sandblasting and UV irradiation. The shear bond strength was measured and analyzed using the Kruskal-Wallis test (α=0.
View Article and Find Full Text PDFObjectives: Marginal discoloration of luting cement may affect the appearance of esthetic restorations. This study evaluated the color stability of current adhesive resin cements after immersion in coffee.
Materials And Methods: Four dual-cured resin cements (Clearfil SA cement Automix Universal, Maxcem Elite Clear, Maxcem Elite Yellow, and RelyX Unicem2 Automix A2) and two chemical-cured resin cements (Super-Bond C&B Clear and Super-Bond C&B Esthetic) were examined.
The aim of the present study was to characterize the effects of the ultraviolet light (UV) irradiation period on the bond strength of fiber-reinforced composite (FRC) posts to core build-up resin. Three types of FRC posts were prepared using polymethyl methacrylate, urethane dimethacrylate, and epoxy resin. The surfaces of these posts were treated using UV irradiation at a distance of 15 mm for 0 to 600 s.
View Article and Find Full Text PDFThis study evaluated the effects of the fabrication process on tensile bond strength between maxillofacial silicone elastomer and acrylic resin. A common maxillofacial silicone elastomer (VST-50), two primers (Sofreliner primer and R-SI-LINE Plasticbond), and two acrylic resins (Unifast III and Palapress Vario) were selected. Silicone elastomer between primed acrylic resin plates were polymerized using a metal flask mold or a flaskless stone mold.
View Article and Find Full Text PDFJ Mech Behav Biomed Mater
January 2014
The aim of this study was to investigate volume loss and worn surfaces' morphologies of eight composite resins: Durafill VS (DUR), Clearfil AP-X (APX), Filtek Z250 (Z250), Filtek Supreme XT (FIL), Kalore (KAL), MI Flow (MFL), Venus Diamond (VED) and Venus Pearl (VEP). Disc-shaped specimens were fabricated and mounted in a ball-on-disc wear testing machine and abraded in water or with the third-body media, poppy seed slurry and polymethyl methacrylate (PMMA) slurry. Volume loss (n=5) was determined after 50k sliding cycles, and analyzed using two-way ANOVA (α=0.
View Article and Find Full Text PDFPurpose: Several methods have been used to measure the impact force absorption capacities of mouthguard materials; however, the relationships among these measurement systems have not been clearly determined. The purpose of the present study was to evaluate the impact force-absorbing capability of materials using a drop-ball system with film sensors and load cells to clarify the relationship between these two sensor systems.
Materials And Methods: Disk-shaped specimens (1, 2, and 3 mm thick) were prepared using three commercial thermoplastic mouthguard materials (Bioplast, Impact Guard, MG 21) and one experimental mouthguard material [mixture of Poly (ethyl methacrylate)].
The objective of this study was to evaluate the effect of the concentration of calcium chloride (CaCl2) solution on the surface hardness of restorative glass ionomer cements (GICs). Two high-viscosity GICs, Fuji IX GP and GlasIonomer FX-II, were immersed in several concentrations of CaCl2 solution for 1 day and 1 week. The immersed specimen surfaces were evaluated using microhardness testing, grazing incidence X-ray diffraction, and energy-dispersive X-ray spectroscopy.
View Article and Find Full Text PDF