Objective: The purpose of this study was to evaluate the correlation between the radiographic and ultrasonographic measurements of craniocaudal displacement of the left hemidiaphragm.
Methods: Forty-nine patients with clinical indications for interventional procedures prospectively underwent radiographic evaluation of left hemidiaphragmatic mobility and B-mode ultrasonographic measurement of craniocaudal displacement of the hilum and the inferior pole of the spleen. Ultrasonography was performed with a 3.
Purpose: To evaluate the correlation and agreement between ultrasonographic (US) measurement of craniocaudal displacement of the left intrahepatic branches of the portal vein and radiographic measurement of right hemidiaphragmatic mobility.
Materials And Methods: Fifty-one patients with indications for abdominal angiography or percutaneous cholangiography prospectively underwent radiographic evaluation of right hemidiaphragmatic mobility and B-mode US measurement of craniocaudal displacement of the left intrahepatic branches of the portal vein. US was performed by using a 3.