Publications by authors named "Naidong W"

Angiopoietin-like protein (ANGPTL) 4 is a key factor in the regulation of lipid and glucose metabolism in metabolic diseases. ANGPTL4 is highly expressed in various cancers, but the regulation of energy metabolism in tumours remains to be determined. This study explored the role of ANGPTL4 in aerobic glycolysis, glutamine consumption and fatty acid oxidation in nonsmall cell lung cancer (NSCLC) cells.

View Article and Find Full Text PDF

A rapid, sensitive and specific LC-MS-MS method has been developed for the determination of clarithromycin (CLA) in human plasma using roxithromycin (ROX) as the internal standard. Samples were prepared via liquid-liquid extraction with methyl tert-butyl ether (MTBE) and chromatographed on a Supelco RP(18) (4.6 x 50 mm, 3 microm particle size) column with a mobile phase consisting of acetonitrile:methanol:60 mM (pH 3.

View Article and Find Full Text PDF

S-phenylmercapturic acid is widely accepted as a specific biomarker for the evaluation of benzene exposure. Here, we describe a fast, specific and sensitive high-performance liquid achromatography coupled with tandem mass spectrometry (LC-MS/MS) method that has been developed and validated for the determination of S-phenylmercapturic acid in human urine. Isotope-labeled S-phenylmercapturic acid-d5 was used as internal standard to improve the method ruggedness.

View Article and Find Full Text PDF

Bioanalytical methods using liquid/liquid extraction (LLE) and liquid chromatography with electrospray tandem mass spectrometry (LC-MS/MS) are widely used. The organic extracts need to be evaporated and reconstituted, hampering further improvement of throughput and automation. In this study, we demonstrated a novel approach of eliminating these two steps in 96-well LLE by using hydrophilic interaction chromatography with MS/MS (HILIC-MS/MS) on silica column with high organic/low aqueous mobile phase.

View Article and Find Full Text PDF

This article presents an analytical approach that used chemical derivatization to enhance mass spectrometric (MS) response in electrospray ionization (ESI) mode of 1-hydroxypyrene (1-OHP), a commonly used biomarker to monitor human exposure to polycyclic aromatic hydrocarbons (PAHs). The enhancement successfully enabled the desired detection of 50 pg/mL in human urine. The introduction of an MS-friendly dansyl group to 1-OHP enhanced both ionization efficiency in the ESI source and collision-activated dissociation (CAD) in the collision cell.

View Article and Find Full Text PDF

In the present work, for the first time, a liquid chromatographic method with tandem mass spectrometric detection (LC-MS/MS) for the simultaneous analysis of norethindrone, and ethinyl estradiol, was developed and validated over the concentration range of 50-10000pg/ml and 2.5-500pg/ml, respectively, using 0.5 ml of plasma sample.

View Article and Find Full Text PDF

Trifluoroacetic acid (TFA) is a commonly used additive in HPLC and LC-MS analysis of basic compounds. It is also routinely added to aqueous-organic mobile phases utilized in the hydrophilic interaction chromatography-electrospray tandem mass spectrometry (HILIC-ESI/MS/MS) technique used in our laboratories for bioanalysis. However, TFA is known to suppress the ESI signals of analytes due to its ability to form gas-phase ion pairs with positively-charged analyte ions.

View Article and Find Full Text PDF

In vitro metabolic stability experiments using microsomes or other liver preparations are important components in the discovery and lead-optimization stages of compound selection in the pharmaceutical industry. Currently, liquid chromatography-tandem mass spectrometric (LC-MS/MS) support of in vitro metabolic stability studies primarily involves the monitoring of disappearance of parent compounds, using selected reaction monitoring (SRM) on triple-quadrupole instruments. If moderate to high turnover is observed, separate metabolite identification experiments are then conducted to characterize the biotransformation products.

View Article and Find Full Text PDF

A high-throughput liquid chromatography/tandem mass spectrometry (LC/MS/MS) method, which combines on-line sample extraction through turbulent flow chromatography with a monolithic column separation, has been developed for direct injection analysis of drugs and metabolites in human plasma samples. By coupling a monolithic column into the system as the analytical column, the method enables running 'dual-column' extraction and chromatography at higher flow rates, thus significantly reducing the time required for the transfer and mixing of extracted fraction onto the separation column as well as the time for gradient separation. A strategy of assessing and reducing the matrix suppression effect on the on-line extraction LC/MS/MS has also been discussed.

View Article and Find Full Text PDF

A hydrophilic interaction liquid chromatographic method with tandem mass spectrometry for the determination of atenolol, a beta-blocking agent, in human plasma has been developed and validated over the curve range of 10--2000 ng/mL. The assay was based on protein precipitation followed by evaporation of the extraction solvent, reconstitution with acetonitrile, and chromatography on an Hypersil silica column (50 x 4.6 mm) using a low aqueous--high organic mobile phase.

View Article and Find Full Text PDF

A high-throughput bioanalytical method based on automated sample transfer, automated solid phase extraction, and hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS) analysis, has been developed for the determination of cetirizine, a selective H(1)-receptor antagonist. Deuterated cetirizine (cetirizine-d(8)) was synthesized as described and was used as the internal standard. Samples were transferred into 96-well plates using an automated sample handling system.

View Article and Find Full Text PDF

Isoniazid and cetirizine do not retain well on reversed-phase columns due to their high polarity. Silica columns, when operated under hydrophilic interaction conditions, do provide excellent retention of these compounds. We have developed simple and proof of concept analytical methods for the analysis of isoniazid and cetirizine in animal and human plasma, respectively.

View Article and Find Full Text PDF

A highly sensitive bioanalytical method based on a simple liquid/liquid extraction and hydrophilic interaction liquid chromatography with tandem mass spectrometry (HILIC/MS/MS) analysis has been developed, validated and transferred for the determination of 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL), a tobacco-specific nitrosamine metabolite. Deuterated NNAL (NNAL-d(4)) was synthesized and used as the internal standard. This method can be used for the analysis of free and total NNAL (free NNAL plus NNAL-gluc) in K(3)-EDTA human plasma.

View Article and Find Full Text PDF

An ultra-sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the analysis of oral contraceptive ethinyl estradiol (EE) was developed and validated over the curve range of 2.5-500 pg/mL using 1 mL of human plasma sample. Ethinyl estradiol and the internal standard, ethinyl estradiol tetra-deuterated (EE-d4), were extracted from the plasma matrix with methyl t-butyl ether, derivatized with dansyl chloride and then back-extracted into hexane.

View Article and Find Full Text PDF

A sensitive, simple, fast and rugged hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS) method for the determination of paroxetine was developed and validated over curve range 0.050-50 ng/mL using only 0.4 mL plasma.

View Article and Find Full Text PDF

This review article summarizes the recent progress on bioanalytical LC-MS/MS methods using underivatized silica columns and aqueous/organic mobile phases. Various types of polar analytes were extracted by using protein precipitation (PP), liquid/liquid extraction (LLE) or solid-phase extraction (SPE) and were then analyzed using LC-MS/MS on the silica columns. Use of silica columns and aqueous/organic mobile phases could significantly enhance LC-MS/MS method sensitivity, due to the high organic content in the mobile phase.

View Article and Find Full Text PDF

Methods using TLC densitometry with fluorescence detection are described for the assay and purity control of tetracycline (TC), chlortetracycline (CTC), and oxytetracycline (OTC) in animal feeds and premixes. With a silica gel layer previously sprayed with 10% (m/v) sodium EDTA solution adjusted to pH 8.0 or 9.

View Article and Find Full Text PDF

A sensitive method using liquid chromatography with tandem mass spectrometric detection (LC/MS/MS) was developed and validated for the simultaneous analysis of antihistamine drug loratadine (LOR) and its active metabolite descarboethoxy-loratadine (DCL) in human plasma. Deuterated analytes, i.e.

View Article and Find Full Text PDF

A bioanalytical method using automated sample transferring, automated liquid/liquid extraction (LLE) and hydrophilic interaction liquid chromatography-tandem mass spectrometry was developed for the determination of fluconazole in human plasma. Samples of 0.05 ml were transferred into 96-well plate using automatic liquid handler (Multiprobe II).

View Article and Find Full Text PDF

It has become increasingly popular in drug development to conduct discovery pharmacokinetic (PK) studies in order to evaluate important PK parameters of new chemical entities (NCEs) early in the discovery process. In these studies, dosing vehicles are typically employed in high concentrations to dissolve the test compounds in dose formulations. This can pose significant problems for the liquid chromatography/tandem mass spectrometric (LC/MS/MS) analysis of incurred samples due to potential signal suppression of the analytes caused by the vehicles.

View Article and Find Full Text PDF
Article Synopsis
  • Automated solid-phase extraction (SPE) and liquid chromatography with electrospray tandem mass spectrometry (LC/MS/MS) are key techniques in the pharmaceutical industry for analyzing compounds.
  • This study introduces a new method that simplifies the process by eliminating manual steps like drying and reconstituting analytes, using low aqueous/high organic mobile phases instead.
  • The optimized methods were tested on various pharmaceutical compounds and validated according to FDA guidelines, enabling the processing of 96 samples in just one hour.
View Article and Find Full Text PDF

Ultrafast liquid chromatography/tandem mass spectrometry (LC/MS/MS) bioanalysis was demonstrated with the use of packed silica columns operated under elevated flow rates. A special effort has been made to achieve ultrafast analysis without sacrificing chromatographic resolution. Two multiple analyte/metabolites assays, (1) morphine/morphine-6-glucuronide(M6G)/morphine-3-glucuronide(M3G) and (2) midazolam/1'-hydroxymidazolam/4-hydroxymidazolam, were used to demonstrate the speed, sensitivity, peak shape and separation of the ultrafast methods utilizing silica columns.

View Article and Find Full Text PDF

A liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for the analysis of antiviral agent ribavirin in human plasma and serum. The samples (0.1 ml) were extracted from the matrix using a simple protein precipitation procedure.

View Article and Find Full Text PDF

A simple, rapid and specific high-performance liquid chromatography coupled with tandem mass spectrometry (LC-MS-MS) has been developed and validated for the determination of ketoconazole in human plasma. The method used diethyl ether to extract the ketoconazole and the internal standard (I.S.

View Article and Find Full Text PDF