Background: There have been several proposals by researchers for the introduction of Artificial Intelligence (AI) technology due to its promising role in radiotherapy practice. However, prior to the introduction of the technology, there are certain general recommendations that must be achieved. Also, the current challenges of AI must be addressed.
View Article and Find Full Text PDFA framework has been developed for dosimetric evaluation in mammography, using the GATE Monte Carlo (MC) platform, to simulate a MAMMOMAT 3000 Nova mammograph (Siemens) available at the University Hospital Center "1st November 1954" of Oran (EHU Oran 1er Novembre, 1954), Algeria. Calculated quantities such half-value layer (HVL), Entrance Surface Dose (ESD) and Mean Glandular Dose (MGD) have been compared to experimental data in order to validate the modeling of mammography examinations. Results are consistent with previous studies and show a good agreement between measurements and Monte Carlo calculations.
View Article and Find Full Text PDFThis scoping review provides overview on the historical and major developments, current status, quantitative magnetic resonance (MR) studies and the role of medical physics bodies in MR imaging in Africa. The study analyzed MRI availability in 32 (59 %) of the 54 African countries. South Africa and Egypt have the most dominant MR systems.
View Article and Find Full Text PDFA pilot study has concerned the most frequent computed tomography examinations (CT). This represents the first results based on actual survey for diagnostic reference levels (DRLs) establishment in Algeria. A total number of 2540 patients underwent this survey that has included the recording of CT parameters, computed tomography dose index (CTDIvol) and dose-length product of the head, thorax, abdomen, abdomen-pelvis (AP), lumbar spine (LS) and thorax-abdomen-pelvis (TAP) performed on standard patients.
View Article and Find Full Text PDFObjective: To survey procedures and protocols in paediatric computed tomography (CT) in 40 less resourced countries.
Methods: Under a project of the International Atomic Energy Agency, 146 CT facilities in 40 countries of Africa, Asia, Europe and Latin America responded to an electronic survey of CT technology, exposure parameters, CT protocols and doses.
Results: Modern MDCT systems are available in 77 % of the facilities surveyed with dedicated paediatric CT protocols available in 94 %.
Objective: The purpose of this study was to assess the frequency of pediatric CT in 40 less-resourced countries and to determine the level of appropriateness in CT use.
Materials And Methods: Data on the increase in the number of CT examinations during 2007 and 2009 and appropriate use of CT examinations were collected, using standard forms, from 146 CT facilities at 126 hospitals.
Results: The lowest frequency of pediatric CT examinations in 2009 was in European facilities (4.
In an early work we have demonstrated the possibility of using Monte Carlo generated pencil beams for 3D electron beam dose calculations. However, in this model the electron beam was considered as monoenergetic and the effects of the energy spectrum were taken into account by correction factors, derived from measuring central-axis depth dose curves. In the present model, the electron beam is considered as polyenergetic and the pencil beam distribution of a clinical electron beam, of a given nominal energy, is represented as a linear combination of Monte Carlo monoenergetic pencil beams.
View Article and Find Full Text PDFObjective: The purpose of our study was to investigate the level of radiation protection of patients and staff during interventional procedures in 20 countries of Africa, Asia, and Europe.
Subjects And Methods: In a multinational prospective study, information on radiation protection tools, peak skin dose (PSD), and kerma-area product (KAP) was provided by 55 hospitals in 20 mainly developing countries (nine mostly in Eastern Europe, five in Africa, and six in Asia).
Results: Nearly 40% of the interventional rooms had an annual workload of more than 2,000 patients.