Upon cooling, condensed-matter systems typically transition into states of lower symmetry. The converse-i.e.
View Article and Find Full Text PDFBackground Long-term respiratory effects can occur after COVID-19 pneumonia (CP). The COVID Lung Ultrasound Study (COVIDLUS) aimed to investigate the utility of serial lung ultrasound (LUS) to track functional and physiological recovery after hospitalisation in patients with CP. Methods Between April 2021 and April 2022, 21 patients were recruited at discharge (D0).
View Article and Find Full Text PDFIEEE Trans Appl Supercond
August 2019
With the improving energy resolution of transitionedge sensor (TES) based microcalorimeters, performance verification and calibration of these detectors has become increasingly challenging, especially in the energy range below 1 keV where fluorescent atomic X-ray lines have linewidths that are wider than the detector energy resolution and require impractically high statistics to determine the gain and deconvolve the instrumental profile. Better behaved calibration sources such as grating monochromators are too cumbersome for space missions and are difficult to use in the lab. As an alternative, we are exploring the use of pulses of 3 eV optical photons delivered by an optical fiber to generate combs of known energies with known arrival times.
View Article and Find Full Text PDFWe have specialized astronomical applications for X-ray microcalorimeters with superconducting transition edge sensors (TESs) that require exceptionally good TES performance, but which operate in the small-signal regime. We have therefore begun a program to carefully characterize the entire transition surface of TESs with and without the usual zebra stripes to see if there are reproducible local "sweet spots" where the performance is much better than average. These measurements require precise knowledge of the circuit parameters.
View Article and Find Full Text PDFIEEE Trans Appl Supercond
August 2019
Time-division multiplexing (TDM) is the backup readout technology for the X-ray Integral Field Unit (X-IFU), a 3,168-pixel X-ray transition-edge sensor (TES) array that will provide imaging spectroscopy for ESA's Athena satellite mission. X-0IFU design studies are considering readout with a multiplexing factor of up to 40. We present data showing 40-row TDM readout (32 TES rows + 8 repeats of the last row) of TESs that are of the same type as those being planned for X-IFU, using measurement and analysis parameters within the ranges specified for X-IFU.