Publications by authors named "N Stolpman"

Background: Per the Centers for Medicare and Medicaid Services (CMS) Code of Federal Regulations (CFR) 482.23(c) regarding medication administration, hospital policies and procedures must identify time-critical scheduled medications which must be administered within 30 minutes either before or after the scheduled dosing time, for a total administration window of 1 hour.

Objective: The general objective of this analysis was to determine whether there was a difference in meeting medication administration goals when comparing time-critical to non-time-critical scheduled medication administration in both intensive care units (ICUs) and general medical floors at a large, academic medical center.

View Article and Find Full Text PDF

Background: In outpatient populations, hypoglycemia has been associated with tramadol. We sought to determine the magnitude of risk for hypoglycemia associated with tramadol use in hospitalized patients.

Methods: During a 2-year period of observation, adult inpatients who received ≥1 dose of tramadol were identified and their medical records were reviewed.

View Article and Find Full Text PDF

Purpose: Results of a study to determine the 90-day stability of dronabinol capsules stored under various temperature conditions are reported.

Methods: High-performance liquid chromatography (HPLC) with ultraviolet (UV) detection was used to assess the stability of dronabinol capsules (synthetic delta-9-tetrahydrocannabinol [Δ9-THC] mixed with high-grade sesame oil and other inactive ingredients and encapsulated as soft gelatin capsules) that were frozen, refrigerated, or kept at room temperature for three months. The dronabinol capsules remained in the original foil-sealed blister packs until preparation for HPLC-UV assessment.

View Article and Find Full Text PDF

Purpose: To measure the effects associated with sequential implementation of electronic medication storage and inventory systems and product verification devices on pharmacy technical accuracy and rates of potential medication dispensing errors in an academic medical center.

Methods: During four 28-day periods of observation, pharmacists recorded all technical errors identified at the final visual check of pharmaceuticals prior to dispensing. Technical filling errors involving deviations from order-specific selection of product, dosage form, strength, or quantity were documented when dispensing medications using (a) a conventional unit dose (UD) drug distribution system, (b) an electronic storage and inventory system utilizing automated dispensing cabinets (ADCs) within the pharmacy, (c) ADCs combined with barcode (BC) verification, and (d) ADCs and BC verification utilized with changes in product labeling and individualized personnel training in systems application.

View Article and Find Full Text PDF