The sodium concentration gradient in the kidney (from the cortex to the medulla) serves to regulate fluid homeostasis and is tightly coupled to renal function. It was previously shown that renal function and pathophysiology can be characterized in rat kidneys by measuring the sodium gradient with (23)Na MRI. This study demonstrates for the first time the ability of (23)Na MRI to map the distribution of sodium in the human kidney and to quantify the corticomedullary sodium gradient.
View Article and Find Full Text PDFThe clinical detection of evolving acute tubular necrosis (ATN) and differentiating it from other causes of renal failure are currently limited. The maintenance of the corticomedullary sodium gradient, an indicator of normal kidney function, is presumably lost early in the course of ATN. Herein, sodium magnetic resonance imaging (23Na MRI) was applied to study the early alteration in renal sodium distribution in rat kidneys 6 h after the induction of ATN.
View Article and Find Full Text PDFThere is evidence in the literature indicating a significant static field inhomogeneity in the human breast. A nonhomogenous field results in line broadening and frequency shifts in MRS and can cause intensity loss and spatial errors in MRI. Thus, there is a clear rationale for determining the regional variations in the static field homogeneity in the breast and providing strategies to correct them.
View Article and Find Full Text PDFRenal function is highly correlated with the sodium concentration gradient along the corticomedullary axis. The application of 3D high-resolution sodium magnetic resonance imaging (MRI) provided a means to quantify in vivo the spatial and temporal changes in renal tissue sodium concentration under normal and diuretic conditions. A detailed, pixel-by-pixel analysis of the intact rat kidney sodium MR images yielded a quantitative measure of the corticomedullary sodium gradient before and at early and later times after the administration of two distinct diuretic agents, furosemide and mannitol.
View Article and Find Full Text PDFJ Magn Reson Imaging
March 2005
Purpose: To develop a fully automated algorithm for combining multivoxel magnetic resonance spectroscopy (MRS) data acquired with a phased-array coil.
Materials And Methods: The frequency-domain fitting method of LCModel (Provencher SW, Magn Reson Med 1993;30:672-679) was utilized to analyze the individual data sets. The phase corrections and the metabolite areas were then extracted from the LCModel output files for each individual spectrum.