Publications by authors named "N Kunugita"

To determine the eye lens dose (3 mm dose equivalent [Hp(3)]) received by spine surgeons during myelography and evaluate the effectiveness of radiation-protective glasses and x-ray tube system positioning in reducing radiation exposure. This study included spine surgeons who performed myelography using over- or under-table x-ray tube systems. Hp(3) was measured for each examination using a radio-photoluminescence glass dosimeter (GD-352M) mounted on radiation-protective glass.

View Article and Find Full Text PDF

Seasonal variations of chemical compounds in indoor air and outdoor air and personal exposure to these chemicals were continuously monitored for 6 years using four types of passive sampling devices: PSD-BPE/DNPH packed with 2,4-dinitrophenylhydrazine and trans-1,2-bis(2-pyridyl)ethylene coated silica for ozone and carbonyls; PSD-VOC packed with Carboxen 572 or Active Carbon Beads particles for volatile organic compounds; PSD-TEA packed with triethanolamine impregnated silica for acid gases; and PSD-TEA packed with phosphoric acid impregnated silica for basic gases. Many chemical compounds except for nitrogen dioxide, formic acid, and benzene showed seasonal variations with high concentrations in summer and low concentrations in winter. In particular, formaldehyde, nonanal, 2-ethyl-1-hexanol, 2,2,4-trimethyl-1,3-pentanediol monoisobutyrate, and ammonia concentrations showed remarkable seasonal variation.

View Article and Find Full Text PDF

Chronic radiation exposure increases the risk of skin damage of medical personnel engaged in radiology. However, hand dose measurements in computed tomography (CT) for diagnostic purposes have not been evaluated. The occupational radiation dose to the hands of CT assistants was herein investigated to evaluate its compliance with the equivalent dose limit for the hand (500 mSv/year).

View Article and Find Full Text PDF

An additional extremity monitoring using a ring badge must be appropriately conducted for inhomogeneous exposure around radiation workers' extremity. Commercially available glass dosemeters are characterized in terms of Hp(0.07) for the application of additional extremity monitoring.

View Article and Find Full Text PDF

We performed an experimental investigation on occupational exposure of the eye lens and the extremity of radiation workers engaged in handling of highly activated materials in a small research accelerator facility. Using a simplified physical phantom to simulate the relevant inhomogeneous radiation exposure situations, the personal dose equivalents obtained at the eye lens and the extremities of radiation workers handling heavily radioactive converters were measured together with the dose measured by personal dosemeters worn on their trunk. Results of mockup experiments and the Monte Carlo calculations suggest that the quantitative estimation of the eye lens doses can be estimated from the trunk dose, while the extremity doses vary considerably from the dose readings from the trunk, depending on the use of simple point-source or volume source geometry.

View Article and Find Full Text PDF