Publications by authors named "N J Skaer"

Fibroins' transition from liquid to solid is fundamental to spinning and underpins the impressive native properties of silk. Herein, we establish a fibroin heavy chain fold for the Silk-I polymorph, which could be relevant for other similar proteins, and explains mechanistically the liquid-to-solid transition of this silk, driven by pH reduction and flow stress. Combining spectroscopy and modelling we propose that the liquid Silk-I fibroin heavy chain (FibH) from the silkworm, Bombyx mori, adopts a newly reported β-solenoid structure.

View Article and Find Full Text PDF

The aim of the current study was to verify if a previously developed silk fibroin scaffold for meniscal replacement is able to restore the physiological distribution of contact pressure (CP) over the articulating surfaces in the human knee joint, thereby reducing peak loads occurring after partial meniscectomy. The pressure distribution on the medial tibial articular surface of seven human cadaveric knee joints was analysed under continuous flexion-extension movements and under physiological loads up to 2,500 N at different flexion angles. Contact area (CA), maximum tibiofemoral CP, maximum pressure under the meniscus and the pressure distribution were analysed for the intact meniscus, after partial meniscectomy as well as after partial medial meniscal replacement using the silk fibroin scaffold.

View Article and Find Full Text PDF

Most previous studies investigated the remarkably low and complex friction properties of meniscus and cartilage under constant loading and motion conditions. However, both load and relative velocity within the knee joint vary considerably during physiological activities. Hence, the question arises how friction of both tissues is affected by physiological testing conditions occurring during gait.

View Article and Find Full Text PDF

Purpose: To restore meniscal function after excessive tissue damage, a silk fibroin implant for partial meniscal replacement was developed and investigated in an earlier sheep model. After 6 months implantation, it showed promising results in terms of chondroprotection and biocompatibility. To improve surgical fixation, the material was subjected to optimisation and a fibre mesh was integrated into the porous matrix.

View Article and Find Full Text PDF

Meniscal injury is typically treated surgically via partial meniscectomy, which has been shown to cause cartilage degeneration in the long-term. Consequently, research has focused on meniscal prevention and replacement. However, none of the materials or implants developed for meniscal replacement have yet achieved widespread acceptance or demonstrated conclusive chondroprotective efficacy.

View Article and Find Full Text PDF