Publications by authors named "N J Brendish"

Article Synopsis
  • - The study aimed to evaluate two host-response tests (TriVerity and MeMed BV) for accurately distinguishing between bacterial and viral acute respiratory infections (ARIs), addressing the issue of inappropriate antibiotic use.
  • - 169 patients were tested; results showed that TriVerity had a Positive Percentage Agreement (PPA) of 81% while MeMed BV had a PPA of 96%, though both had limitations in accurately identifying non-bacterial infections.
  • - The findings suggest both tests are similarly accurate for distinguishing bacterial infections, but further studies on their impact on antibiotic use and costs are needed to enhance clinical practices.
View Article and Find Full Text PDF

Background: A novel single-use, analyser-free, molecular point-of-care test for SARS-CoV-2 (Veros COVID-19 test, Sherlock Biosciences) could reduce time to results and improve patient care and flow in the emergency department (ED), but its performance in this setting is unknown.

Methods: Adults aged ≥18 years presenting to Southampton General Hospital (UK) with suspected COVID-19 were tested with the Veros COVID-19 test in addition to standard of care near-patient PCR. Measures of diagnostic accuracy were calculated for the Veros COVID-19 test stratified by Ct value.

View Article and Find Full Text PDF

Importance: Rapid tests for respiratory viruses, including multiplex panels, are increasingly available in emergency departments (EDs). Their association with patient outcomes remains unclear.

Objective: To determine if ED rapid respiratory virus testing in patients with suspected acute respiratory infection (ARI) was associated with decreased antibiotic use, ancillary tests, ED length of stay, and ED return visits and hospitalization and increased influenza antiviral treatment.

View Article and Find Full Text PDF

Objectives: FebriDx is a CE-marked, FDA-approved point-of-care test that detects the antiviral host response protein Myxovirus Resistance Protein A (MxA), in addition to C-reactive protein, using finger-prick blood. FebriDx MxA detection had a high negative predictive value for COVID-19 in symptomatic adults presenting to hospital in the first waves of the pandemic and was used subsequently as a 'rule out' triage tool in Emergency departments. The diagnostic accuracy of FebriDx MxA in the current context of co-circulation of influenza, SARS-CoV-2, and Respiratory Syncytial Virus (RSV), and in the era of COVID-19 vaccination, is unknown.

View Article and Find Full Text PDF

Background: Single-occupancy isolation rooms are a finite resource in UK hospitals but are crucial in preventing transmission of infection. Patients with suspected gastroenteritis are nursed in single-occupancy rooms, but delays in laboratory testing lead to non-infectious patients remaining isolated for prolonged periods unnecessarily. Rapid molecular test panels for gastrointestinal pathogens have a run time of around 1 h but their clinical impact is unknown.

View Article and Find Full Text PDF