Objective: This retrospective, single centre, comparative effectiveness study aimed to compare the long term outcomes of percutaneous arteriovenous fistulae (pAVF) and surgically created arteriovenous fistulae (sAVF) created in the proximal forearm for haemodialysis access.
Methods: Data were reviewed from a prospectively maintained database on patients who underwent pAVF or sAVF creation from September 2017 to September 2023. A total of 217 pAVFs (61 WavelinQ and 156 Ellipsys) and 158 sAVFs were analysed.
Background: The provision of a metabolic substrate is one mechanism by which hypothermic machine perfusion (HMP) of kidneys provides clinical benefit. This study aimed to describe metabolism in ex vivo human kidneys undergoing HMP before transplantation using C-labeled glucose as a metabolic tracer.
Methods: Cadaveric human kidneys were perfused with modified clinical-grade perfusion fluid (kidney perfusion solution [KPS-1], Organ Recovery Systems), in which glucose was uniformly enriched with the stable isotope C ([U-C] glucose).
Background: Clinically-oriented outcome measures are increasingly being recognized as lacking in consideration of factors important to patients. There is an emerging move of guideline bodies advocating a more patient-centred approach. Aneurysms in autogenous arteriovenous fistula (AVF) can be considered unsightly and a constant reminder for patients of their dependence on dialysis.
View Article and Find Full Text PDFPurpose: To assess multicenter two-year patency outcomes of endovascular arteriovenous fistulas (endoAVF) created with the WavelinQ device.
Materials And Methods: Patients who had fistulas created at three centers from January 2018 to December 2020 were included in this retrospective study. In total, 112 patients underwent endoAVF creation [40 females, 72 males; mean age 60 years (range 18-88)].
Background: Introducing new procedures and challenging established paradigms requires well-designed randomised controlled trials (RCT). However, RCT in surgery present unique challenges with much of treatment tailored to the individual patient circumstances, refined by experience and limited by organisational factors. There has been considerable debate over the outcomes of arteriovenous grafts (AVG) compared to AVF, but any differences may reflect differing practice and potential variability.