The purpose of this study was to determine the effect of regulating factors on the oxygen equilibrium curve (OEC) under standard conditions and then to calculate the oxygen extraction between arterial and jugular venous blood in healthy Standardbred horses. The results were compared to those previously obtained in humans and cattle, using the same experimental method. The partial oxygen pressure at 50% saturation of haemoglobin, measured under standard conditions (standard P50), was 24.
View Article and Find Full Text PDF