Laboratory quality control has been developed for several decades to ensure patients' safety, from a statistical quality control focus on the analytical phase to total laboratory processes. The sigma concept provides a convenient way to quantify the number of errors in extra-analytical and analytical phases through the defect per million and sigma metric equation. Participation in a sigma verification program can be a convenient way to monitor analytical performance continuous quality improvement.
View Article and Find Full Text PDFBackground And Objective: For reliability of laboratory results, all methods, instruments, and reagents should be evaluated The Nova StatSensor creatinine meter is a hand-held device for determination of creatinine concentration in the whole blood Therefore, the device has to be validated or verified before performing.
Material And Method: Observational analysis method with cross sectional design was used in this evaluation. The commercial reagents and coded samples were prepared for linearity, precision, accuracy, and interference studies.
The 99 formalin fxed paraffin-embedded ovarian tissue specimens of Epithelial Ovarian Cancer (EOC) patients treated at the Gynecologic Oncology Unit, King Chulalongkorn Memorial Hospital between January 1, 1996 and December 31, 1999, were immuno-stained with BRCA antibody using the immunohistochemical method. According to the criteria for BRCA1 immunohistochemical evaluation (neoplastic nuclear staining more than 10%), 12 (12.1%) of the 99 specimens showed positive BRCA1 expression.
View Article and Find Full Text PDFJ Med Assoc Thai
September 2005
Objectives: To evalate compare the calculated LDL determined by the Friedewald formula when Tg < 200 mg/dL, 200-399 mg/dL, and > or =400 mg/dL against a direct method.
Material And Method: Samples from 202 participants (122 males, 80 females, aged 20-87 years old) were determined for cholesterol, triglyceride (Tg), high-density lipoprotein (HDL), and low-density lipoprotein (LDL) at Department of Laboratory Medicine, King Chulalongkorn Memorial Hospital (KCMH). LDL was determined by Friedewald formula and a direct method.
Southeast Asian J Trop Med Public Health
May 2005
The objective of this descriptive study was to review the usefulness and relevance of the present parameters provided in an annual laboratory health checkup program. Three hundred sixty-four volunteers were randomly selected, composed of 141 males and 223 females age 15 to 81 years old. Samples from all the volunteers were analyzed for CBC, FBG, BUN, Cr, uric acid, Chol, HDLc, Tg, AST, ALT, ALP, UA and stool examination.
View Article and Find Full Text PDF