The evaluation of possible improvement in the use of Gd in cancer therapy, in reference to gadolinium in cancer therapy (GdNCT), has been analysed. At first the problem of the gadolinium compounds toxicity was reviewed identifying the Motexafin Gadolinium as the best. Afterwards, the spectrum of IC and Auger electrons was calculated using a special method.
View Article and Find Full Text PDFRadiat Prot Dosimetry
May 2006
Gadolinium has been recently proposed, as neutron capture agent in NCT (Neutron Capture Therapy), due to both the nuclide high neutron capture cross section, and the remarkable selective uptake inside tumour tissue that Gd-loaded compounds, can provide. When a neutron external source is supplied, different Gd nuclear reactions, and the generated Auger electrons in particular, cause a high local energy deposition, which results in a tumour cell inactivation. Preliminary micro- as well as macrodosimetric Monte Carlo computational investigations show that the tumour-to-healthy tissue biological damage ratio is in close relation to the neutron beam energy spectrum.
View Article and Find Full Text PDFRadiat Prot Dosimetry
March 2006
The management of radioactive waste is a key issue for the present and future use of nuclear energy. In this frame, high temperature reactors (HTRs) have, among others, the capability to burn actinides. After a short introduction on HTRs, the performances of two MC-based burnup codes (Monte Carlo continuous energy burnup and MONTEBURNS) in assessing the ability of these reactors to burn actinides are compared.
View Article and Find Full Text PDFAppl Radiat Isot
November 2004
The idea to couple the treatment planning system (TPS) to the information on the real boron distribution in the patient acquired by positron emission tomography (PET) is the main added value of the new methodology set-up at DIMNP (Dipartimento di Ingegneria Meccanica, Nucleare e della Produzione) of University of Pisa, in collaboration with the JRC (Joint Research Centre) at Petten (NL). This methodology has been implemented in a new TPS, called Boron Distribution Treatment Planning System (BDTPS), which takes into account the actual boron distribution in the patient's organ, as opposed to other TPSs used in BNCT that assume an ideal uniform boron distribution. BDTPS is based on the Monte Carlo technique and has been experimentally validated comparing the computed main parameters (thermal neutron flux, boron dose, etc.
View Article and Find Full Text PDFTo evaluate scatter fraction and scatter pair spatial distribution, experimental methods are generally used. These methods make use of a line source, placed along the FOV axis, inserted in a cylindrical phantom filled with air or water. The accuracy of these experimental methodologies can be tested by the use of a Monte Carlo method.
View Article and Find Full Text PDF