This case-report describes severe acute respiratory failure in a patient with a COVID-19 positive nasopharyngeal swab that spontaneously resolved within a few hours. It is speculated that the virus may have caused a fleeting pulmonary vasospasm.
View Article and Find Full Text PDFBackground: Until recently, it has been considered essential to maintain the use of a double-limb circuit in patients with amyotrophic lateral sclerosis (ALS) to avoid rebreathing expired air during invasive mechanical ventilation. Currently, life-sustaining home ventilators can work with a single, lighter circuit that is easier to manage. Our aim was to evaluate the effectiveness and safety of a single-limb circuit with intentional leaks (passive circuit) in comparison with a circuit with an expiratory valve (active circuit), in subjects with ALS who use invasive home ventilation.
View Article and Find Full Text PDFMonaldi Arch Chest Dis
May 2014
Aim: To evaluate the severity of airway obstruction in patients affected by chronic obstructive pulmonary disease (COPD) in the presence of concomitant restriction due to morbid obesity.
Methods: Lung function test, six-minute walking distance (6MWD) test, body mass index measurement (BMI), and determination of dyspnoea using the Modified Medical Research Council Dyspnoea Scale (MMRC) were performed on each patient referred to our department according to their individual respiratory diagnosis or symptoms. Analysis was performed on smokers or ex-smokers patients, with both dyspnoea and chronic productive cough, showing non fully reversible airflow obstruction, with normal-weight (NW: BMI 22 to 24 kg/m2) or morbid-obesity (MO: BMI > or = 40 kg/m2).