Publications by authors named "Mutic S"

This review explores biochar's potential as a sustainable and cost-effective solution for remediating organic pollutants, particularly polycyclic aromatic hydrocarbons (PAHs) and pesticides, in water. Biochar, a carbon-rich material produced from biomass pyrolysis, has demonstrated adsorption efficiencies exceeding 90% under optimal conditions, depending on the feedstock type, pyrolysis temperature, and functionalization. High surface area (up to 1500 m/g), porosity, and modifiable surface functional groups make biochar effective in adsorbing a wide range of contaminants, including toxic metals, organic pollutants, and nutrients.

View Article and Find Full Text PDF

Incident reporting and learning systems provide an opportunity to identify systemic vulnerabilities that contribute to incidents and potentially degrade quality. The narrative of an incident is intended to provide a clear, easy to understand description of an incident. Unclear, incomplete or poorly organized narratives compromise the ability to learn from them.

View Article and Find Full Text PDF

The rapid and sensitive voltammetric determination of organic UV filters benzophenone-3 (BP-3) and avobenzone (AVO) was performed by an ionic liquid carbon paste electrode (IL-CPE). Namely, the synthesized pyridinium-based ILs, 1-butyl-3-methylpyridinium chloride ([N-C-3CPy]Cl) and 1-ethoxyethyl-3-methylpyridinium chloride ([N-COC-3CPy]Cl) were compared as bulk CPE modifiers for BP-3 determination. [N-C-3CPy]Cl-CPE showed more favorable interactions with the target analyte, and it was tested for AVO determination, too.

View Article and Find Full Text PDF
Article Synopsis
  • Researchers developed a cholesterol biosensor by immobilizing cholesterol oxidase on a composite electrode, enhancing its electrochemical performance.
  • The biosensor demonstrated a strong linear response for cholesterol concentrations between 0.31 and 2.46 µM, with a detection limit of 0.13 µM and a high level of precision in measurements.
  • Successful application of the biosensor in human blood serum samples showed excellent recovery rates, indicating it could be a reliable alternative to current commercial cholesterol testing methods.
View Article and Find Full Text PDF

Introduction: A kV imager coupled to a novel, ring-gantry radiotherapy system offers improved on-board kV-cone-beam computed tomography (CBCT) acquisition time (17-40 seconds) and image quality, which may improve CT radiotherapy image-guidance and enable online adaptive radiotherapy. We evaluated whether inter-observer contour variability over various anatomic structures was non-inferior using a novel ring gantry kV-CBCT (RG-CBCT) imager as compared to diagnostic-quality simulation CT (simCT).

Materials/methods: Seven patients undergoing radiotherapy were imaged with the RG-CBCT system at breath hold (BH) and/or free breathing (FB) for various disease sites on a prospective imaging study.

View Article and Find Full Text PDF
Article Synopsis
  • The study evaluates the immune response to COVID-19 vaccines in older people living with HIV (PWH), focusing on antibody durability over six months following the initial vaccination.
  • At the six-month mark, all participants had detectable levels of antibodies, but there was a noted decline in antibody levels from the second visit to the third.
  • The research also looks at T-cell responses and the side effects of booster shots, showing a comprehensive approach to understanding vaccine effectiveness in this demographic.
View Article and Find Full Text PDF

Active learning is an effective solution to interactively select a limited number of informative examples and use them to train a learning algorithm that can achieve its optimal performance for specific tasks. It is suitable for medical image applications in which unlabeled data are abundant but manual annotation could be very time-consuming and expensive. However, designing an effective active learning strategy for informative example selection is a challenging task, due to the intrinsic presence of noise in medical images, the large number of images, and the variety of imaging modalities.

View Article and Find Full Text PDF

Objectives: Effective and safe COVID-19 vaccines have been developed and have resulted in decreased incidence and severity of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection and can decrease secondary transmission. However, there are concerns about dampened immune responses to COVID-19 vaccination among immunocompromised patients, including people living with HIV (PLWH), which may blunt the vaccine's efficacy and durability of protection. This study aimed to assess the qualitative SARS-CoV-2 vaccine immunogenicity among PLWH after vaccination.

View Article and Find Full Text PDF

Purpose: Stereotactic body radiation therapy (SBRT) has demonstrated clinical benefits for patients with metastatic and/or unresectable cancer. Technical considerations of treatment delivery and nearby organs at risk can limit the use of SBRT in large tumors or those in unfavorable locations. Spatially fractionated radiation therapy (SFRT) may address this limitation because this technique can deliver high-dose radiation to discrete subvolume vertices inside a tumor target while restricting the remainder of the target to a safer lower dose.

View Article and Find Full Text PDF

The analytical performance of sensitive and cost-effective electrochemical sensors based on ionic liquids (ILs) with the bis(trifluoromethylsulfonyl)imide anion, [NTf2]-, and the imidazolium cation with different alkyl chain lengths for electrochemical oxidation of verapamil (VER) was investigated. 1-Ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([EMIM][NTf2]), 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([BMIM][NTf2]) and 1-hexyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([HMIM][NTf2]) were studied as possible materials for modification of a carbon paste electrode (CPE) for trace-level determination of VER. The experimental parameters including selection of the working electrode, the pH of working media, and the amount of CPE modifiers were investigated.

View Article and Find Full Text PDF

Purpose: To characterize the shielding design and leakage radiation from a newly released ring gantry linac (Halcyon, Varian Medical Systems).

Methods: To assess the radiation leakage surrounding headshield and the radiation level after the beam stopper, measurements were made with GafChromic films. To evaluate the in-room radiation levels, the radiation leakage in the isocenter plane was measured with a large volume spherical ionization chamber (Exradin A6, Standard Imaging).

View Article and Find Full Text PDF

Purpose: The current approach to Linac beam dosimetry verification is typically performed utilizing a three-dimensional (3D) water tank system. The 3D beam scanning process is cumbersome, labor intensive, error-prone, and costly. This is especially challenging for the new Ethos system and MR Linacs with a ring gantry.

View Article and Find Full Text PDF

Diffusion-weighted imaging (DWI) provides a valuable diagnostic tool for tumor evaluation. Yet, it is difficult to acquire daily MRI data sets in the traditional radiotherapy clinical setting due to patient burden and limited resources. However, integrated MRI radiotherapy treatment systems facilitate daily functional MRI acquisitions like DWI during treatment exams.

View Article and Find Full Text PDF

We characterized MRI isocenter variation at various gantry positions in two 0.35 T MRgRT systems using two independent methods. First, image center-based quantification was employed on 3D volumetric and 2D cine images of a 24 cm diameter spherical phantom at various gantry positions in the MRI QA mode.

View Article and Find Full Text PDF

We develop a fully automated QA process to compare the image quality of all kV CBCT protocols on a Halcyon linac with ring gantry design, and evaluate image quality stability over a 10-month period. A total of 19 imaging scan and reconstruction protocols were characterized with measurement on a newly released QUART phantom. A set of image analysis algorithms were developed and integrated into an automated analysis suite to derive key image quality metrics, including HU value accuracy on density inserts, HU uniformity using the background plate, high contrast resolution with the modulation transfer function (MTF) from the edge profiles, low contrast resolution using the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), slice thickness with the air gap modules, and geometric accuracy with the diameter of the phantom.

View Article and Find Full Text PDF

Purpose: The annual quality assurance (QA) of Leksell Gamma Knife (LGK) systems are typically performed using films. Film is a good candidate for small field dosimetry due to its high spatial resolution and availability. However, there are multiple challenges with using film; film does not provide real-time measurement and requires batch-specific calibration.

View Article and Find Full Text PDF

Purpose: MRI is the gold-standard imaging modality for brain tumor diagnosis and delineation. The purpose of this work was to investigate the feasibility of performing brain stereotactic radiosurgery (SRS) with a 0.35 T MRI-guided linear accelerator (MRL) equipped with a double-focused multileaf collimator (MLC).

View Article and Find Full Text PDF

The goal of this study was to develop a Monte Carlo (MC)-based analytical model that can predict the in-room ambient dose equivalent from a Mevion gantry-mounted passively scattered proton system. The Mevion S250 and treatment vault were simulated using the MCNPX MC code. The results of the in-room neutron dose measurements, using an FHT 762 WENDI-II detector, were employed to benchmark the MC-derived values.

View Article and Find Full Text PDF

To present a tumor motion control system during free breathing using direct tumor visual feedback to patients in 0.35 T magnetic resonance-guided radiotherapy (MRgRT). We present direct tumor visualization to patients by projecting real-time cine MR images on an MR-compatible display system inside a 0.

View Article and Find Full Text PDF

The not-for-profit organization La LIGA Nacional Contra el Cáncer, with its hospital Instituto de Cancerología (INCAN), is responsible for cancer treatment of much of the indigent population in Guatemala, a country with a population of 16 million. Annually, approximately 70% of patients at INCAN are seen in late stages of cancer, which places a great strain on the hospital's limited resources. Private clinics account for 75% of radiation therapy centers in Guatemala and have considerable resources.

View Article and Find Full Text PDF

Purpose: To develop an efficient and automated methodology for beam data validation for a preconfigured ring gantry linear accelerator using scripting and a one-dimensional (1D) tank with automated couch motions.

Materials And Methods: Using an application programming interface, a program was developed to allow the user to choose a set of beam data to validate with measurement. Once selected the program generates a set of instructions for radiation delivery with synchronized couch motions for the linear accelerator in the form of an extensible markup language (XML) file to be delivered on the ring gantry linear accelerator.

View Article and Find Full Text PDF

Purpose: To test the feasibility of a simplified, robust, workflow for intracranial stereotactic radiation therapy (SRT) using a ring gantry linear accelerator (RGLA) equipped with a dual-layer stacked, staggered, and interdigitating multileaf collimator.

Materials And Methods: Twenty recent clinical SRT cases treated using a radiosurgery c-arm linear accelerator were anonymized. From these data sets, a new planning workflow was developed and used to replan these cases, which then were compared to their clinical counterparts.

View Article and Find Full Text PDF

Purpose: To calculate in- and out-of-field neutron spectra and dose equivalent, using Monte Carlo (MC) simulation, for a Mevion gantry-mounted passively scattered proton system in craniospinal irradiation. An analytical model based on the MC calculations that estimates in- and out-of-field neutron dose equivalent from proton Craniospinal irradiation (CSI) was also developed.

Methods: The MCNPX MC code was used to simulate a Mevion S250 proton therapy system.

View Article and Find Full Text PDF

Purpose: The purpose is: (a) Relate magnetic resonance imaging (MRI) quality recommendations for radiation therapy (RT) to B field homogeneity; (b) Evaluate manufacturer specifications of B homogeneity for 34 commercial whole-body MRI systems based on the MRI quality recommendations and RT application; (c) Measure field homogeneity in five commercial MRI systems and one commercial MRI-Linac used in RT and compare the results with their B homogeneity specifications.

Methods: Magnetic resonance imaging quality recommendations for spatial integrity, image blurring, fat saturation, and null banding in RT were developed based on the literature. Guaranteed (maximum) and typical B field homogeneity specifications for various diameter spherical volumes (DSVs) were provided by GE, Philips, Siemens, and Canon.

View Article and Find Full Text PDF