Background: Small mesenteric hiatal hernias (SMHHs) are defined as a small group of internal hernias (IHs) that frequently diagnosed in children. However, SMHHs are relatively rare in adults. Bowel loop herniation via an abnormal mesenteric defect can lead to strangulated intestinal obstruction.
View Article and Find Full Text PDFThe magnetic ground state of single crystalline RuO_{2} was investigated by the muon spin rotation and relaxation (μSR) experiment. The spin precession signal due to the spontaneous internal magnetic field B_{loc}, which is expected in the magnetically ordered phase, was not observed in the temperature range 5-400 K. Muon sites were evaluated by first-principles calculations using dilute hydrogen simulating muon as pseudohydrogen, and B_{loc} was simulated for the antiferromagnetic structures with a Ru magnetic moment |m_{Ru}|≈0.
View Article and Find Full Text PDFIncoherent digital holography (IDH) with a sequential phase-shifting method enables high-definition 3D imaging under incoherent lights. However, sequential recording of multiple holograms renders IDH impractical for 3D videography. In this study, we propose grating-based in-line geometric-phase-shifting IDH.
View Article and Find Full Text PDFIncoherent digital holography (IDH) enables the recording of holograms with incoherent light. However, there is unnatural bokeh with ringing on reconstructed 2D images, owing to the diffraction calculation based on the coherent nature of the light. Thus, we propose a transformation method that converts it into incoherent bokeh.
View Article and Find Full Text PDFWe propose a simultaneous dual-page reproduction for holographic data storage (HDS) with high-efficiency and high-speed data reproduction by reusing a transmitted reference beam that passes through a recording medium after data reconstruction. The transmitted reference beam enters the recording medium at a different incident angle to reproduce different data pages; thus, this technology can double data-transfer rates without increasing the laser's output power or preparing another laser source. In the experiment, neighboring angle-multiplexed two data pages were simultaneously reconstructed and a data transfer rate of 1.
View Article and Find Full Text PDFIncoherent digital holography (IDH) requires no spatial coherence; however, it requires high temporal coherence for a light source to capture holograms with high spatial resolution. Temporal coherence is often enhanced with a bandpass filter, reducing the light utilization efficiency. Thus, there is a trade-off between spatial resolution and light utilization efficiency.
View Article and Find Full Text PDFJ Opt Soc Am A Opt Image Sci Vis
July 2021
Incoherent digital holography (IDH) enables passive 3D imaging through the self-interference of incoherent light. IDH imaging properties are dictated by the numerical aperture and optical layout in a complex manner [Opt. Express27, 33634 (2019)OPEXFF1094-408710.
View Article and Find Full Text PDFOccupational exposure to nickel oxide (NiO) is an important cause of respiratory tract cancer. Toxicity is known to be associated with the dissociated component, i.e.
View Article and Find Full Text PDFLung metastasis of gastric cancer often presents as multiple pulmonary metastases or cancerous lymphadenopathy, which is rarely indicated for surgery and has a poor prognosis. We report a case of solitary metastases that were surgically resected. The patient underwent distal gastrectomy for stomach cancer and then received chemotherapy for abdominal lymph node metastasis.
View Article and Find Full Text PDFIncoherent digital holography (IDH) enables passive 3D imaging under spatially incoherent light; however, the reconstructed images are seriously affected by detector noise. Herein, we derive theoretical sampling requirements for IDH to reduce this noise via simple postprocessing based on spatial averaging. The derived theory provides a significant insight that the sampling requirements vary depending on the recording geometry.
View Article and Find Full Text PDFWe developed a new head supporting device to provide accurate correction of rotational setup during image-guided radiation therapy (IGRT), evaluating its correction performance and the efficacy of dose distribution in stereotactic radiotherapy (SRT) using a helical tomotherapy (HT) system. The accuracy of rotational motion was measured using an electronic inclinometer; we compared device angles and measurement values from 0.0° to 3.
View Article and Find Full Text PDFAlthough three-dimensional (3D) imaging and extended depth-of-field (DOF) imaging are completely opposite techniques, both provide much more information about 3D scenes and objects than does traditional two-dimensional imaging. Therefore, these imaging techniques strongly influence a wide variety of applications, such as broadcasting, entertainment, metrology, security and biology. In the present work, we derive a generalised theory involving incoherent digital holography to describe both 3D imaging and quasi-infinite-DOF (QIDOF) imaging, which allows us to comprehensively discuss the functions of each imaging technique.
View Article and Find Full Text PDFSingle-shot phase-shifting incoherent digital holography with multiplexed checkerboard phase gratings is proposed for acquiring holograms of moving objects. The gratings presented here play the following three roles: dividing the beams, modulating the curvature of spherical beams, and introducing different phase shifts. With the gratings of our proposed method, four individual holograms of a spatially incoherent light are formed on an image sensor.
View Article and Find Full Text PDFWe have conducted animal toxicity tests of chemicals for a chemical safety program implemented by the Ministry of Economy, Trade and Industry of Japan. Here we conducted a combined repeated-dose and reproductive/developmental toxicity screening test of benzene, 1,1'-oxybis-, tetrapropylene derivs. (BOTD).
View Article and Find Full Text PDFG-protein-coupled receptors (GPCRs) participate in diverse physiological functions and are promising targets for drug discovery. However, there are still over 140 orphan GPCRs whose functions remain to be elucidated. is one of the orphan GPCRs that is expressed in the rat and human brain.
View Article and Find Full Text PDFA water dispersible granule (WDG) was prepared through direct granulation of an agrochemical suspension composed of a mixture of sodium lignosulphonate and polyvinyl alcohol (PVA) as a binder using a fluidized bed granulator. The evaluation of various physicochemical properties showed that the mass median diameter (MMD) and disintegration time of the WDG increased with an increase in the PVA content. It was also revealed that the MMD was positively correlated with the viscosity of the agrochemical suspension and that the disintegration time decreased with an increase in solubility of the binder mixture.
View Article and Find Full Text PDFTo increase the reproduced data transfer rate in holographic memory, we have investigated simultaneous reproduction of two data pages. By irradiating s- and p-polarization reference beams whose angle gap is equal to the angle between the neighboring data pages in angle-multiplexed holograms, two different data pages can simultaneously be reproduced with a bit error rate low enough to decode. This technology is effective to double the data transfer rate in holographic memory.
View Article and Find Full Text PDFWe have carried out animal toxicity tests of chemicals for a chemical safety program implemented by the Ministry of Economy, Trade, and Industry of Japan. Here, we tested 1-tert-butoxy-4-chlorobenzene in a combined repeat-dose and developmental and reproductive toxicity test. The test chemical was administered daily by gavage to 9-week-old Crl:CD (SD) rats at doses of 0, 20, 100, and 500 mg/kg/d.
View Article and Find Full Text PDF4-Methoxy-2-nitroaniline (4M2NA) is widely used as an intermediate for the synthesis of dyes, pigments and other chemical compounds. Since 4M2NA has amino-group and nitro-group on the benzene ring, it was expected that it induced obvious hemolytic anemia. We conducted a combined repeated dose and reproductive/developmental toxicity screening test according to Organisation for Economic Co-operation and Development (OECD) Test Guideline No.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
March 2014
In this paper, we propose a detection method for blurred regions in radiographs. The method involves edge detection using a Sobel filter, manually determining the region of interest (ROI), feature calculation, and classification using a support vector machine. We applied our method to 14 phantom images (7 normal images, 7 blurred images) and 14 clinical images (12 normal images, 2 blurred images).
View Article and Find Full Text PDFJ Phys Condens Matter
November 2013
Fully absorption coefficient corrected Raman spectra were obtained in La2-xSrxCuO4. The B1g spectra have a Fleury-Loudon type two-magnon peak (resonant term) whose energy decreases from 3180 cm(-1) (394 meV) to 440 cm(-1) (55 meV) on increasing the carrier density from x = 0 to 0.25, while the B2g spectra have a 1000-3500 cm(-1) (124-434 meV) hump (hill) whose lower-edge energy increases from x = 0 to 0.
View Article and Find Full Text PDFJ Phys Condens Matter
October 2013
Ethyl tertiary-butyl ether (ETBE) is commonly used as an oxygenated gasoline additive. In this study, we evaluated its developmental toxicity in rats. ETBE was administered by gavage to 21 or 22 pregnant female Sprague-Dawley rats per group at dose levels of 0, 100, 300 and 1000 mg/kg/day from days 5 through 19 postcoitum to assess its effects on pregnant animals and their embryos and fetuses applied to the OECD testing guideline (no.
View Article and Find Full Text PDFtert-Butylhydrazine monohydrochloride was daily administered by gavage to groups of Crl:CD (SD)IGS rats at doses of 0 (control), 0.8, 4, or 20 mg/kg/day. Twelve males per group were treated for a total of 42 days from 14 days before mating.
View Article and Find Full Text PDF