Publications by authors named "Munmohan Virdee"

Background: A novel aggregated multiposition noncontact mapping (AMP-NCM) algorithm is proposed to diagnose cardiac arrhythmias.

Objective: The purpose of this study was to computationally determine an accuracy threshold and to compare the accuracy and clinical utility of AMP-NCM to gold standard contact mapping.

Methods: In a cellular automata model, the number of catheter positions and chamber coverage were varied to establish accuracy requirements for clinically relevant AMP-NCM.

View Article and Find Full Text PDF

Aims: The very long-term outcome of patients who survive the first few years after receiving cardiac resynchronization therapy (CRT) has not been well described thus far. We aimed to provide long-term outcomes, especially with regard to the occurrence of sudden cardiac death (SCD), in CRT patients without (CRT-P) and with defibrillator (CRT-D).

Methods And Results: A total of 1775 patients, with ischaemic or non-ischaemic dilated cardiomyopathy, who were alive 5 years after CRT implantation, were enrolled in this multicentre European observational cohort study.

View Article and Find Full Text PDF

A 67-year-old man presented to the emergency department with sudden onset of severe presyncope. He reported that he had a permanent pacemaker implanted in 2006 following atrioventricular node ablation for persistent atrial fibrillation (AF). After suffering increasing shortness of breath, he underwent upgrade to cardiac resynchronisation therapy (CRT) in 2016.

View Article and Find Full Text PDF

Aim: There is controversy and sparse data on whether substrate based techniques in addition to pulmonary vein isolation (PVI) confer benefit in the catheter ablation of persistent atrial fibrillation (AF), especially if long standing. We performed an observational study to assess whether substrate based ablation improved freedom from atrial arrhythmia.

Methods: A total of 286 patients undergoing first ablation procedures for persistent AF with PVI only(n = 79), PVI plus linear ablation(n = 85), or PVI plus complex fractionated electrogram (CFAE) and linear ablation(n = 107) were followed.

View Article and Find Full Text PDF

Objective: In patients indicated for cardiac resynchronisation therapy (CRT), the choice between a CRT-pacemaker (CRT-P) versus defibrillator (CRT-D) remains controversial and indications in this setting have not been well delineated. Apart from inappropriate therapies, which are inherent to the presence of a defibrillator, whether adding defibrillator to CRT in the primary prevention setting impacts risk of other acute and late device-related complications has not been well studied and may bear relevance for device selection.

Methods: Observational multicentre European cohort study of 3008 consecutive patients with ischaemic or non-ischaemic dilated cardiomyopathy and no history of sustained ventricular arrhythmias, undergoing CRT implantation with (CRT-D, n=1785) or without (CRT-P, n=1223) defibrillator.

View Article and Find Full Text PDF

Women traditionally have been and are still underrepresented in research in many important areas of cardiology, and guideline recommendations which also encompass women are mostly based on research conducted predominantly in men. However, there is plausible cause to believe that sex may have a potential influence on the benefit derived from the implantable cardioverter-defibrillators (ICD), alone or in association with cardiac resynchronization therapy. We assessed the possible relationship between sex and outcome with ICD implantation in the setting of primary prevention, by pooling the results of MUSTT, MADIT-II, DEFINITE, COMPANION, SCD-HeFT and DANISH trials in a meta-analysis.

View Article and Find Full Text PDF

Aims: Outcome of persistent atrial fibrillation (AF) ablation remains suboptimal. Techniques employed to reduce arrhythmia recurrence rate are more likely to be embraced if cost-effectiveness can be demonstrated. A single-centre observational study assessed whether use of general anaesthesia (GA) in persistent AF ablation improved outcome and was cost-effective.

View Article and Find Full Text PDF

Background: Patients with nonischemic dilated cardiomyopathy (DCM) may be at lower risk for ventricular arrhythmias compared with those with ischemic cardiomyopathy (ICM). In addition, DCM has been identified as a predictor of positive response to cardiac resynchronization therapy (CRT).

Objectives: The aim of this study was to investigate the impact of an additional implantable cardioverter-defibrillator over CRT, according to underlying heart disease, in a large study group of primary prevention patients with heart failure.

View Article and Find Full Text PDF

Aims: Upgrade to cardiac resynchronization therapy (CRT) should be offered to patients who have developed pacing-induced cardiomyopathy with conventional right ventricular pacing. The extent to which these patients would also benefit from defibrillator back-up at the time of CRT upgrade is, however, unknown.

Methods And Results: Retrospective observational cohort study of 199 patients with pacing-induced cardiomyopathy and no history of sustained ventricular arrhythmia, including 104 upgraded to CRT-Pacemaker (CRT-P) and 95 upgraded to CRT-Defibrillator (CRT-D).

View Article and Find Full Text PDF

Purpose: Six risk stratification scores have been developed to estimate mortality risk in patients receiving an implantable cardioverter-defibrillator (ICD). This study aims at validating and comparing these risk scores in patients having elective ICD generator replacement (GR) and assessing the outcome of patients submitted to this procedure.

Methods: Two hundred twenty three consecutive patients with ischaemic or non-ischaemic dilated cardiomyopathy submitted to elective ICD GR and followed-up for 44 ± 19 months were included.

View Article and Find Full Text PDF

Aims: The Goldenberg risk score, comprising five clinical risk factors (New York Heart Association class >2, atrial fibrillation, QRS duration >120 ms, age >70 years, and urea >26 mg/dL), may help identify patients in whom the survival benefit of the defibrillator may be limited. We aim at assessing whether this score can accurately predict the long-term all-cause mortality risk of patients receiving cardiac resynchronization therapy (CRT) and identify those who are more likely to benefit from the defibrillator.

Methods And Results: In this retrospective observational cohort study, 638 patients with ischaemic or non-ischaemic dilated cardiomyopathy who had CRT-defibrillator (CRT-D) (n = 224) vs.

View Article and Find Full Text PDF

Background: It remains to be determined whether patients receiving cardiac resynchronization therapy (CRT) benefit from the addition of an implantable cardioverter-defibrillator (ICD).

Methods And Results: We performed a literature search looking for studies of patients implanted with CRTs. Comparisons were performed between patients receiving CRT-defibrillator (CRT-D) versus CRT-pacemaker (CRT-P).

View Article and Find Full Text PDF

Aims: Increase in life expectancy has led to increased rate of implantable cardioverter-defibrillator (ICD) implantation in patients in their 80s, but there are no current formal recommendations to guide physicians when elderly patients with ICDs require elective unit replacement (EUR). This study aims at assessing survival and rates of ICD therapies in patients who have had ICD implantation or EUR above the age of 80, focusing on the latter.

Methods And Results: Retrospective analysis of a prospectively kept database of all ICD-related procedures carried out in a single tertiary centre.

View Article and Find Full Text PDF

Aims: Optimal delivery of CRT requires appropriate patient selection and device implantation. Echocardiographic predictors of CRT response individually appear to enhance patient selection, but do not fully reflect the complex underlying myocardial dysfunction. We hypothesized that a multiparametric approach would offer greater predictive value and sought to derive a score incorporating baseline characteristics including: dyssynchrony, LV function, and LV lead position.

View Article and Find Full Text PDF

Objectives: This study was conducted to assess the impact of left ventricular (LV) lead position on longer-term survival after cardiac resynchronization therapy (CRT).

Background: An optimal LV lead position in CRT is associated with improved clinical outcome. A strategy of speckle-tracking echocardiography can be used to guide the implanter to the site of latest activation and away from segments of low strain amplitude (scar).

View Article and Find Full Text PDF

Objective: Studies have shown beneficial effects of cardiac resynchronisation therapy (CRT) on mortality among patients with heart failure. However the incremental benefits in survival from CRT with a defibrillator (CRT-D) are unclear. The choice of appropriate device remains unanswered.

View Article and Find Full Text PDF

Background: Dyssynchrony assessment based on the timing of regional contraction is inherently independent of underlying myocardial contractility. We tested the hypothesis that patient selection for cardiac resynchronization therapy (CRT) would be enhanced using a parameter derived from the net radial strain delay (RSD) for the 12 basal and mid-left ventricular segments (calculated radial strain delay RSD [RSDc]), based on not only timing but also amplitude of segmental strain.

Methods And Results: Echocardiographic data were analyzed in 240 patients with symptomatic heart failure undergoing CRT (New York Heart Association class III/IV; QRS >120 milliseconds; ejection fraction, 23±7%).

View Article and Find Full Text PDF

Purpose: Catheter ablation for paroxysmal atrial fibrillation (PAF) is an effective treatment. Favourable outcomes at 6-12 months post-ablation have been reported using the multi-electrode catheter 'pulmonary vein ablation catheter (PVAC)' but little is known about longer term outcomes. There are also limited data on quality of life (QoL) post-atrial fibrillation (AF) ablation beyond 2 years of follow-up.

View Article and Find Full Text PDF

Aims: Cardiac transplantation (CTX) is an effective treatment for end-stage heart disease. Cardiac arrhythmias are increasingly recognized and associated with significant morbidity and mortality. We aim to describe the clinical and electrophysiological characteristics of patients with atrial arrhythmias occurring late after CTX.

View Article and Find Full Text PDF

A woman presented with broad complex tachycardia. She was converted to sinus rhythm with intravenous amiodarone and continued on oral amiodarone. The amiodarone was stopped 3 weeks later as she was pregnant.

View Article and Find Full Text PDF

Aims: Noninvasive cardiac output (CO) measurement (NICOM) is a novel method to assess ventricular function and offers a potential alternative for optimization of cardiac resynchronization therapy (CRT) devices. We compared the effect of NICOM-based optimization to no optimization (empiric settings) on CRT outcomes.

Methods: Two hundred and three patients undergoing CRT were assessed in two consecutive nonrandomized groups; an empiric group (n = 54) was programmed to "out of the box" settings with a fixed AV delay of 120 ms and a VV delay of 0 ms; and the optimization group (n = 149) underwent adjustments of both the AV and VV delays according to the greatest improvement in resting CO.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_session4dotlsqtk18gcve9fof0snpr77dhqeag): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once