To compare the detection efficacy of radionuclide lymphoscintigraphy (LS) versus patent blue dye (PBD) technique for hidden sentinel lymph node (SLN) in breast cancer patients and to determine which modality is better for SLN detection. One hundred and thirty-four early stage breast cancer female patients with clinically negative axilla who underwent post technetium-99m nanocolloid injection single photon emission computed tomography (SPECT-CT) for negative SLN on planar imaging were studied prospectively between 2015 and 2017. Following SPECT-CT, patients underwent peroperative gamma probe count detection GP-CD and PBD technique.
View Article and Find Full Text PDF