Publications by authors named "Mubina A Quader"

Background & Aims: Hepatocyte transplantation partially corrects genetic disorders and has been associated anecdotally with reversal of acute liver failure. Monitoring for graft function and rejection has been difficult, and has contributed to limited graft survival. Here we aimed to use preparative liver-directed radiation therapy, and continuous monitoring for possible rejection in an attempt to overcome these limitations.

View Article and Find Full Text PDF

Background: Mixed chimerism is associated with donor-specific tolerance. Spleen or splenocyte allotransplantation (Tx) is recognized as potentially tolerogenic. There is no definitive report comparing chimerism levels following spleen and splenocyte Tx in a large animal model.

View Article and Find Full Text PDF

Background: Human liver has an unusual sensitivity to radiation that limits its use in cancer therapy or in preconditioning for hepatocyte transplantation. Because the characteristic veno-occlusive lesions of radiation-induced liver disease do not occur in rodents, there has been no experimental model to investigate the limits of safe radiation therapy or explore the pathogenesis of hepatic veno-occlusive disease.

Methods And Materials: We performed a dose-escalation study in a primate, the cynomolgus monkey, using hypofractionated stereotactic body radiotherapy in 13 animals.

View Article and Find Full Text PDF

Allograft/xenograft rejection is associated with "passenger leukocyte" migration from the organ into recipient lymph nodes. In Study 1, we attempted to deplete leukocytes from potential kidney "donor" pigs, using two regimens of total body irradiation. A dose of 700 cGy was administered, followed by either 800 cGy ("low-dose") or 1,300 cGy ("high dose") with the kidneys shielded.

View Article and Find Full Text PDF

Background: Although infertility is a serious concern in survivors of pediatric cancers, little is known about the influence of the degree of sexual maturation at the time of irradiation on spermatogenic recovery after treatment. Thus, we address this question in a non-human primate model, the rhesus monkey (Macaca mulatta).

Methods: Two pubertal (testis size 3 and 6.

View Article and Find Full Text PDF

Three types of films, Kodak EDR2, Gafchromic EBT, and Gafchromic MD-V2-55, were used to measure relative output factors of 4 and 8 mm collimators of the Leksell Gamma Knife Perfexion. The optical density to dose calibration curve for each of the film types was obtained by exposing the films to a range of known doses. Ten data points were acquired for each of the calibration curves in the dose ranges from 0 to 4 Gy, 0 to 8 Gy, and 0 to 80 Gy for Kodak EDR2, Gafchromic EBT, and Gafchromic MD-V2-55 films, respectively.

View Article and Find Full Text PDF

The calibration of Leksell Gamma Knife Perfexion (LGK PFX) is performed using a spherical polystyrene phantom 160 mm in diameter, which is provided by the manufacturer. This is the same phantom that has been used with LGK models U, B, C, and 4C. The polystyrene phantom is held in irradiation position by an aluminum adaptor, which has stainless steel side-fixation screws.

View Article and Find Full Text PDF

Object: The recently introduced Leksell Gamma Knife (LGK) Perfexion is an entirely new system with a different beam geometry compared with the LGK 4C. The new Perfexion system has 192 cobalt-60 sources that are fixed on 8 sectors (each sector has 24 sources). Each sector can be moved independently of the others and can be set to 1 of 5 different positions: 3 positions defining collimator sizes of 4, 8, and 16 mm; an off position (sources are blocked); and a home position.

View Article and Find Full Text PDF